Search Results

Refine
1 - 12 of 14 Products for '1064 10 Mj' Page 1 of 2 |

1064 10 Mj

Pulsed Q-Switched

Pulsed Q-Switched

…MATRIX CW Lasers MATRIX CW Lasers MATRIX 1064-10-CW is a diode-pumped, solid-state, continuous wave laser, with output powers of up to 10W at 1064 nm. MATRIX QS DPSS Lasers MATRIX QS DPSS Lasers The MATRIX family of diode-pumped, solid-state, Q-switch lasers is available in three wavelengths:…

EnergyMax-USB/RS User Manual

EnergyMax-USB/RS User Manual

…to 500 mJ 850 µJ to 1J 50 µJ to 50 mJ 12 µJ to 20 mJ 500 nJ to 600 µJ
Noise Equivalent Energy < 160 µJ < 40 µJ < 85 µJ < 5 µJ < 1.2 µJ < 50 nJ
Wavelength Range (µm) 0.19 to 12
Active Area Diameter
(mm)
50 50 25 25 10 10
Max. Avg. Power (W) 10 10 5 5 4…

250 kHz Ultrafast Amplifiers

250 kHz Ultrafast Amplifiers

…energies from 4 µJ to 100 mJ, and repetition-rates from 10 Hz to 500 kHz. Ultrafast Laser Oscillators and Amplifiers Ultrafast Laser Oscillators and Amplifiers Industrial-grade reliability with repetition rates from 10 Hz to 100 MHz and pulse energies from nJ-level to 100 mJ, all backed by a highly…

YAG/Harmonics and IR Sensors

YAG/Harmonics and IR Sensors

…J-50MB-IR operates from 500 to 2940 nm and provides high damage threshold for long pulse lasers often
* Enable pulse energy measurements from 1 mJ to 10J (contact factory for part number for >3J applications)
* Spectral compensation characteristics built into each unit
* Onboard sensors provide…

EnergyMax-USB-RS-Sensors-Guide FORMFIRST.pdf

EnergyMax-USB-RS-Sensors-Guide FORMFIRST.pdf

…12 1.6 mJ 2J 10 - - 24 300 57 50 MaxBlack None 1064
J-50MB-LE 0.19 to 12 400 µJ 500 mJ 10 - - 24 300 57 50 MaxBlack None 1064
J-25MB-HE 0.19 to 12 850 µJ 1J 5 10 15 - 1000 17 25 MaxBlack None 1064
J-25MB-LE 0.19 to 12 50 µJ 50 mJ 5 10 15 - 1000 17 25 MaxBlack None 1064
J-10MB-HE…

LaserCam-HR II User Manual

LaserCam-HR II User Manual

…at 1064 nm 25 mW/cm2 (with LDFP) at 1064 nm
340 µW/cm2 (without LDFP) at 1064 nm 125 µW/cm2 (without LDFP) at 1064 nm
Pulsed Saturation
0.4 mJ/cm2 (with LDFP) at 1064 nm 0.15 mJ/cm2 (with LDFP) at 1064 nm
2 µJ/cm2 (without LDFP) at 1064 nm 0.7 µJ/cm2 (without LDFP) at 1064 nm…

COHERENT LMC 2016-2017 Catalog .pdf

COHERENT LMC 2016-2017 Catalog .pdf

…to 100 mJ
Standard DB-25
EnergyMax
Energy Range
Capabilities
Wide Dynamic Range for All EnergyMax Sensor Categories
Heat Sink
Model Wavelength5 (nm) None Small Medium Large
J-50MB-HE2 & -LE2 1064 10W - - 24W
J-25MB-HE3 & -LE3 1064 5W 10W 15W -…

COHR LaserCam-HRII DS 0318 2.pdf

COHR LaserCam-HRII DS 0318 2.pdf

…at 1064 nm
90 mW/cm2 at 248 nm5
90 µW/cm2 at 248 nm4
Pulsed Saturation
with LDFP
without LDFP
0.4 mJ/cm2 at 1064 nm
2 J/cm2 at 1064 nm
0.15 mJ/cm2 at 1064 nm
0.7 J/cm2 at 1064 nm
5 mJ/cm2 at 248 nm5
5 J/cm2 at 248 nm4
USB 2.0 Cable 10 ft.…

COHR DiamondFLQ DS 0218 4.pdf

COHR DiamondFLQ DS 0218 4.pdf

…(kW) 5.0 10.0 10.0 8.5 8.5
Pulse Energy4 (mJ) 0.5 1.0 1.0 1.0 1.0
Pulse Width5 (ns) 100 ±20 100 ±20 100 ±20 120 ±20 120 ±20
Pulse Repetition Rate (kHz) 20 to 100 20 to 100 30 to 100 50 to 200 100 to 200
Central Wavelength (nm) 1064 ±2 1064 ±2 1064 ±2 1064 ±2 1064 ±2
Emission…

WaveMaster-Data-Sheet FORMFIRST.pdf

WaveMaster-Data-Sheet FORMFIRST.pdf

…Bandwidth 2 nm @ 400 nm
3 nm @ 600 nm
5 nm @ 1000 nm
Min. Signal 20 µW CW @ 632 nm
2 mJ pulsed @ 1064 nm
Max. Signal 100 mW CW @ 632 nm
100 mJ pulsed @ 1064 nm
Display Update 3 Hz
Size 281 mm wide x 105 mm high x 352 mm deep
Storage Conditions -10°C…

COHR HighLightFL1000P DS 0617.pdf

COHR HighLightFL1000P DS 0617.pdf

…(kHz) Standard: 10 to 30 (others on request)
Max. Pulse Energy (mJ) 100
Pulse Length Range (ns) 10 to 100
Pulse to Pulse Stability (%) ±3
Wavelength (nm) 1064
Excitation Laser diodes
ELECTRICAL RATINGS
Voltage 3 x 230/400 V ±10% or 3 x 277/480 V ±10%; 50/60 Hz; PE…

MATRIX1064&532 DS

MATRIX1064&532 DS

…Specifications
Power Supply Specifications
MATRIXTM 1064 and 532
Solid-State, Q-Switched Laser
1 1064 -Wavelength (nm); 7 - Specified Power (W); 10 - Specified Pulse Repetition Rate (kHz).
2 1064 -Wavelength (nm); 10 - Specified Power (W); 30 - Specified Pulse Repetition…

Please Read Before Continuing

Risk factors: Except for the historical information contained here, many of the matters discussed in this Web site are forward-looking statements, based on expectations at the time they were made, that involve risks and uncertainties that could cause our results to differ materially from those expressed or implied by such statements. These risks are detailed in the “Factors That May Affect Future Results” section of our latest 10-K or 10-Q filing. Coherent assumes no obligation to update these forward-looking statements.


I have read the terms and conditions