1 - 12 of 31 Products for '275' Page 1 of 3 |

275

INNOVA Sabre Laser

INNOVA Sabre Laser

--> INNOVA Sabre INNOVA Sabre provides the ultimate in high-power ion laser performance, combined with extraordinary ease-of-use. A single digital remote module gives you access and control of all critical laser functions such as wavelength acquisition and tuning, automated TEM 00-acquiring shutter,…

Direct Diode High Power Lasers

Direct Diode High Power Lasers

…needed). Free space beam delivery preserves the inherent brightness of the diode laser source and enables the use of an optical system with a large (275 mm) working distance. The unique design of the HighLight D-Series’ compact laser head enables a wide range of output beam size options that won’t…

00 Laser Cooling.book

00 Laser Cooling.book

…FreD/MotoFred
415 (60)
8.5 - 11.6
(2.2 - 3.0)
150 - 275
(22 - 40)
0.47 4.2 (0.165)
Innova 70, Innova 90
Innova 300, 310, 32X
415 (60)
8.5 - 11.6
(2.2 - 3.0)
150 - 275
(22 - 40)
0.47 4.2 (0.165)
PureLight, PureLight Star

Innova Sabre brochure

Innova Sabre brochure

…control,
you can always see what you're doing in
single-line or single-frequency UV operation.You can select each of the lines between
275 nm to 386 nm, and beconfident that
Sabre will automatically handle set-up and
run, flawlessly.
Now that the Innova Series V plasma…

COHR OBIS LaserBox DS 0618 1.pdf

COHR OBIS LaserBox DS 0618 1.pdf

…(4.6 in.)
71.6 mm
(2.8 in.)
27.2 mm
(1.1 in.)
0 mm
(0.0 in.)
Ø7.0 (3) Thru (8X)
279.4 mm (11.0 in.)
275 mm (10.8 in.)
5 Bays for
OBIS Lasers
184.2 mm
(7.3 in.)
Air Intake
with Cleanable
Air Filters
Ø11.4 (0.5 in.)…

COHR ExcimerCatalog2019.pdf

COHR ExcimerCatalog2019.pdf

…100 to 120V AC, 25A, 50/60 Hz switchable, 1-phase
Water Cooling5 2 to 5 l/min. (0.5 to 1.3 gal./min.), 15 to 20°C, connection: 1/2"
Weight 275 kg (605 lbs.) 350 kg (772 lbs.)
Dimensions (L x W x H) 1282 x 375 x 793 mm3
51 x 15 x 31 in.3
1682 x 375 x 793 mm3
67 x 15 x 31…

COHR COMPexSeries DS 0618 8.pdf

COHR COMPexSeries DS 0618 8.pdf

…100 to 120V AC, 25A, 50/60 Hz switchable, 1-phase
Water Cooling5 2 to 5 l/min. (0.5 to 1.3 gal./min.), 15 to 20°C, connection: 1/2"
Weight 275 kg (605 lbs.) 350 kg (772 lbs.)
Dimensions (L x W x H) 1282 x 375 x 793 mm3
51 x 15 x 31 in.3
1682 x 375 x 793 mm3
67 x 15 x 31…

DIAMOND J-3 Series OEM Lasers Preinstallation Manual, Rev. AB

DIAMOND J-3 Series OEM Lasers Preinstallation Manual, Rev. AB

…burst
protection to
--25°C (13°F)
See Note below
Table 3-3. Specification Difference
PRODUCT FLOW RATE INPUT PRESSURE
Optishield 5.7 lpm (1.5 gpm) 206 kPa (30 psi)
TRAC100 5.7 lpm (1.5 gpm) 206 kPa (30 psi)
Dowfrost 8.4 lpm (2.2 gpm) 275 kPa (40 psi)

COHR WP PropagationDispersionMeasurement of sub 10fsPulses 08 29 18.pdf

COHR WP PropagationDispersionMeasurement of sub 10fsPulses 08 29 18.pdf

…800-527-3786 | 408-764-4983
0
20
40
60
80
100
120
140
160
0 25 50 75 100 125 150 175 200 225 250 275 300 325 350
Output pulse duration in fs
GDD in fs2
Pulse broadening effect for different input pulse durations
7 fs pulse
10…

Lasers-for-Life-Sciences-Product-Guide FORMFIRST.pdf

Lasers-for-Life-Sciences-Product-Guide FORMFIRST.pdf

76.2 mm
(3.0 in.)
50 mm
(2.0 in.)
Ø7.0 (3) Thru (8X)
279.4 mm (11.0 in.)
275 mm (10.8 in.)
5 Bays for
OBIS Lasers
184.2 mm
(7.3 in.)
Air Intake
with Cleanable
Air Filters
4-40 Tapped Holes (2X)
3.6 mm (0.14 in.) Deep Both…

Diamond J-2 Series OEM Lasers Preinstallation Manual, Rev. AB

…burst
protection to
- 25°C (- 13°F)
See Note below
Table 3-3. Specification Difference
PRODUCT FLOW RATE INPUT PRESSURE
Optishield 5.7 lpm (1.5 gpm) 103 kPa (15 psi)
WT1000 5.7 lpm (1.5 gpm) 103 kPa (15 psi)
Dowfrost 8.4 lpm (2.2 gpm) 275 kPa (40 psi)

Diamond J-3 Series OEM Lasers Preinstallation Manual, Rev. AC

Diamond J-3 Series OEM Lasers Preinstallation Manual, Rev. AC

…burst
protection to
--25°C (13°F)
See Note below
Table 3-3. Specification Difference
PRODUCT FLOW RATE INPUT PRESSURE
Optishield 5.7 lpm (1.5 gpm) 206 kPa (30 psi)
WT1000 5.7 lpm (1.5 gpm) 206 kPa (30 psi)
Dowfrost 8.4 lpm (2.2 gpm) 275 kPa (40 psi)

Please Read Before Continuing

Risk factors: Except for the historical information contained here, many of the matters discussed in this Web site are forward-looking statements, based on expectations at the time they were made, that involve risks and uncertainties that could cause our results to differ materially from those expressed or implied by such statements. These risks are detailed in the “Factors That May Affect Future Results” section of our latest 10-K or 10-Q filing. Coherent assumes no obligation to update these forward-looking statements.