1 - 10 of 94 Search Results for 3 sigma

1pdf document  ExcimerProductGuide2011 Best match in this PDF  |  All matches in this PDF
…ExciStar XS Excimer Lasers 3. Specifications Wavelength (nm) 157 193 248 351 Max. Repetition Rate (Hz) 200/500 200/500 200/500 200/500 Max. Pulse Energy (mJ) 2 8 12 5 Stabilized Pulse Energy (mJ) 1 5 8 4 Average Pulse Power1 0.2/0.5 1/2.5 1.6/4 0.8/2 Energy Stability1 (sigma, %) 2/3 2/3 2/3 2/3 Beam Dimensions…
Related Searches: 450 laser | braggstar s 200 | microlas attenuator | premix gas

2pdf document  HighRep-RateExcimerLasersforMicromachingRev2 Best match in this PDF  |  All matches in this PDF
…with < 100 µrad (1 Sigma). This picture shows a typical beam pointing stability of 16 µrad (1 Sigma). SPIE USE, V. 2 4971-16 (p.4 of 9) / Color: No / Format: A4/ AF: A4 / Date: 2002-12-30 04:55:44 Please verify that (1) all pages are present, (2) all figures are acceptable, (3) all fonts and special…
Related Searches: resonator | arf laser | excimer laser | krf laser

3pdf document  300WXeClExcimerLaserAnnealingRev2 Best match in this PDF  |  All matches in this PDF
…deviation is specified with Sigma < 2.5%, however, usually the average deviation is below 1 % (1 Sigma). SPIE USE, V. 2 5004-10 (p.2 of 8) / Color: No / Format: A4/ AF: A4 / Date: 2002-12-23 08:08:15 Please verify that (1) all pages are present, (2) all figures are acceptable, (3) all fonts and special characters…
Related Searches: silicon annealing | annealing | excimer laser annealing | ludolf herbst

4pdf document  Paper LPM2004Rev2 Best match in this PDF  |  All matches in this PDF
…operated at a wavelength of 248 nm at 10 Hz is shown in Figure 3. Figure 3: Energy energy stability of a COMPex with smooth ceramic preionization measured over 1000 laser pulses at a wavelength of 248 nm. A typical standard deviation sigma of ca. 1 % is achieved at high pulse energies. 3.2 Beam Homogeneity…
Related Searches: halogen | ceramic | excimer gas | compex

5pdf document  ExciStarXS200500 DSrevA 0910 Best match in this PDF  |  All matches in this PDF
…Hz E(U) 500 Hz Sigma(U) 200 Hz Sigma(U) 500 Hz High Voltage (V) PulseEnergy(mJ) EnergyStability(sigma,%) 0 4 8 12 16 20 700 800 900 1000 1100 1200 1300 1400 1500 0 1 2 3 4 5 6 E(U) 200 Hz E(U) 500 Hz Sigma(U) 200 Hz Sigma(U) 500 Hz High Voltage (V) PulseEnergy(mJ) EnergyStability(sigma,%) System Specifications…
Related Searches: almeta | excistar 200 | excistar xs 200

6ExciStarXS_200&500_DS  (PAGE 2 OF 2)

Sigma(U) 200 Hz
Sigma(U) 500 Hz
High Voltage (V)
PulseEnergy(mJ)
EnergyStability(sigma,%)
0
4
8
12
16
20
700 800 900 1000 1100 1200 1300 1400 1500
0
1
2
3
4
5
6
E(U) 200 Hz
E(U) 500 Hz
Sigma(U)…
Related Searches: excistar 200

7pdf document  IMID Korea 2004 17-4 SLS1Rev2 Best match in this PDF  |  All matches in this PDF
…Whereas the early lasers for ELA delivered 670 mJ at 300 Hz with an energy stability of 3% (sigma), the current model, the LAMBDA STEEL 2000, delivers 1050 mJ at 300 Hz with an energy stability of typical 1.1% (sigma) over more than 55 million pulses (52 hours) with one single gas fill as shown in Figure…
Related Searches: silicon annealing | ela | oled | sequential lateral solidification

8pdf document  LineBeam DS 0710 Best match in this PDF  |  All matches in this PDF
…(±10) (±10) Homogeneity Long Axis (at 96% from mean value) Specification <_1.4%, 2 sigma <_1.4%, 2 sigma <_1.4%, 2 sigma <_1.4%, 2 sigma Typical Value <_1.0%, 2 sigma <_1.0%, 2 sigma <_1.0%, 2 sigma <_1.0%, 2 sigma Steepness short axis (µm) <_100 <_100 <_100 <_100 (90% to 10%), open slit Depth of focus…
Related Searches: oled | homogenizer optics | ltps | pulse duration extender

9pdf document  Solid-StatePulsedHigh-RepetitionRateExcimerLasersRev2 Best match in this PDF  |  All matches in this PDF
…relatively small time delay between electrical trigger signal and emitted light pulse associated with very low temporal jittering of only about 2 ns (1 sigma) facilitates multi-laser synchronized experimental setups as of relevance, e.g. in pump-probe laser spectroscopic investigations. For applications of…
Related Searches: thyratron | thyratron switch | top hat profile | ophthalmic lasers

10IndyStar_DS  (PAGE 2 OF 2)

Homogeneity Long Axis (at 96% from mean value)
Specification <_1.4%, 2 sigma <_1.4%, 2 sigma <_1.4%, 2 sigma <_1.4%, 2 sigma
Typical Value <_1.0%, 2 sigma <_1.0%, 2 sigma <_1.0%, 2 sigma <_1.0%, 2 sigma
Steepness short axis (µm) <_100 <_100 <_100 <_100
(90% to 10%), open slit…


Page 1 2 3 4 5 6 7 8 9 10 of 10 | Next