1 - 12 of 28 Products for '340 Nm' Page 1 of 3 |

340 Nm

COHR ChameleonVUE DS 0817 4.pdf

COHR ChameleonVUE DS 0817 4.pdf

…in an automated hands-free package. VUE SHG is a second harmonic generation system, which can cover 340 nm to 540 nm. VUE THG is a third harmonic generation system, spanning 227 nm to 540 nm. VUE modules can communicate with the built-in spectrometer within the Chameleon laser to automatically…

Chameleon Family

Chameleon Family

…laser from 340 nm to 4000 nm, for ultrafast spectroscopy and non-linear optics studies. Chameleon Family Specifications Output Power (W) Tuning Range (nm) Chameleon Discovery >1.6 W at 800 nm >3.5 W at 1040 nm 660 to 1320, Fixed 1040, Dual Output Chameleon Ultra >2.5 at 800 nm 690 to 1020…

Chameleon Compact OPO and MPX

Chameleon Compact OPO and MPX

…tuning range of 340 nm to 1600 nm, with simple touch screen controls and no manual intervention. This OPO provides hundreds of milliwatts of output power over most of its tuning range that can be expanded to cover also the mid IR region between 1750 nm and 4000 nm. Chameleon MPX - Chameleon…

Chameleon VUE Harmonics Accessory

Chameleon VUE Harmonics Accessory

…of the pump laser varies.
* VUE SHG is a second harmonic generation system, which can cover 340 nm to 540 nm.
* VUE THG is a third harmonic generation system, spanning 227 nm to 540 nm. The modular instrument design is purpose-built to be user-friendly and compact, with software-controlled…

UVblade Excimer Laser

UVblade Excimer Laser

…UV blade 380 UV blade 465 UV blade 750 UV blade 1000 Wavelength (nm) 308 308 308 308 308 Laser Pulse Energy (mJ) 580 580 1000 1000/2000 (high power model) 2000 Repetition Rate (Hz) 200 200 600 600 600 Energy Density (mJ/cm 2) 370 340 330 340/320 (high power model) 315 Beam Length (mm) 250 380 465…

ModeMaster PC M-Squared

ModeMaster PC M-Squared

…the spectral response of the detector. The silicon detector peaks at 900 nm and is at half peak sensitivity at 510 nm and 1050 nm. The germanium detector peaks at 1500 nm and is at half peak sensitivity at 1100 nm and 1650 nm. The pyroelectric detector has a flat spectral response. c. These limits…

Collimating Units

Collimating Units

…250 mm Asymmetric Aspects Ratios 1:1.5/2.0/2.5/3.0 (f170), 1:1.6/2.0/2.6/3.3/4.0 (f226) Optics Material Synthetic fused silica AR-Coating 1030-1090 nm Fiber Interfaces QBH / RQB / QD / LLK-B Features & Benefits
* Prealigned for plug-and-play performance
* Minimum focal shift
* Water-cooled or…

COHR ChameleonCompactOPO-Vis DS 1118 1.pdf

COHR ChameleonCompactOPO-Vis DS 1118 1.pdf

…wavelength tuning of pump for dual color experiments · Full tuning range without change of optics or re-alignment · Gap-free tuning from 340 nm to 1600 nm · Idler option available for tuning up to 4 µm APPLICATIONS · Non-linear Optics · Time Resolved Spectroscopy · Photoluminescence Studies ·…

2016-Ultrafast-Laser-Systems-Catalog.pdf

2016-Ultrafast-Laser-Systems-Catalog.pdf

…Fundamental - High Power (680 nm to 1080 nm) ·
Chameleon Fundamental - Low Power (740 nm to 880 nm) · ·
Chameleon Fundamental - Depleted · · ·
Chameleon SHG - High Power (340 nm to 540 nm) ·
Chameleon SHG - Low Power · ·
OPO Signal (1000 nm to 1600 nm) · ·
OPO Signal -…

COHR RLScatalog 2017revA web.pdf

COHR RLScatalog 2017revA web.pdf

…Fundamental - High Power (680 nm to 1080 nm) ·
Chameleon Fundamental - Low Power (740 nm to 880 nm) · ·
Chameleon Fundamental - Depleted · · ·
Chameleon SHG - High Power (340 nm to 540 nm) ·
Chameleon SHG - Low Power · ·
OPO Signal (1000 nm to 1600 nm) · ·
OPO Signal -…

LaserCam-HR II User Manual

LaserCam-HR II User Manual

…(with LDFP) at 633 nm 5 mW/cm2 (with LDFP) at 633 nm
5 µW/cm2 (without LDFP) at 633 nm 2 µW/cm2 (without LDFP) at 633 nm
70 mW/cm2 (with LDFP) at 1064 nm 25 mW/cm2 (with LDFP) at 1064 nm
340 µW/cm2 (without LDFP) at 1064 nm 125 µW/cm2 (without LDFP) at 1064 nm
Pulsed Saturation…

COHR ChameleonUltra DS 0119 3.pdf

COHR ChameleonUltra DS 0119 3.pdf

…GUI or RS-232 for flexible, intuitive control · On-board spectrometer for real time spectral feedback · Extendable wavelength range from 340 nm to 4000 nm with Compact OPO APPLICATIONS · Multiphoton Excitation (MPE) Microscopy · Non-linear Optics · Time Resolved Spectroscopy · CARS/SRS Microscopy…