1 - 12 of 35 Products for '355 1 60' Page 1 of 3 |

355 1 60

OBIS Continuous Wave Lasers

OBIS Continuous Wave Lasers

…reliability ensures consistent uptime and the lowest cost of ownership in both demanding industrial and research applications. Call +1 800 527 3786 | Outside the U.S. +1 408 764 4983 Coherent has locations across the globe that are available to provide support for any product, service or inquiry.…

MATRIX Family of Q-Switch Lasers

MATRIX Family of Q-Switch Lasers

…Disk Indent card LCD Medical Device Plastic Memory Photopolymer ITO layers Quartz Resistor --> Features & Benefits Power Wavelength 355 nm 532 nm 1064 nm 1 Watt M1; MATRIX 355-YAG MATRIX1064-LP 2 Watt MATRIX 355-1-60; MATRIX 355-1, 5-150 8 Watt MATRIX 355-5-50; MATRIX 355-8-50 MATRIX 532-7-30;…

HYPER RAPID Lasers

HYPER RAPID Lasers

…Beam Divergence, Full Angle (mrad) 85 Beam-Pointing Stability in Full PRF range (µrad / °C) <50 Electric Supply 100 to 230 VAC/50 to 60 Hz/2.5 kW 100 to 230 VAC/50 to 60 Hz/2.5 kW Beam Diameter (μm) ~3000 at 1064 nm ~3000 at 1064 nm Bore-Sight Accuracy ±0.5 mm and <5 mrad Warm-Up Time <40 min from…

Microsoft Word - Understand Different Laser Beam  Rev 1 Final.doc

Microsoft Word - Understand Different Laser Beam Rev 1 Final.doc

…options.
Special attention should be paid to a camera or knife-edge system
when used in the ultraviolet wavelength range from 190 nm to 355
nm. Commonly, knife-edge detectors use a UV-enhanced Si-based
sensor in order to ensure good and stable (long life) performance
over…

COHR MATRIX355 DS 1118 1.pdf

COHR MATRIX355 DS 1118 1.pdf

…Input Power Requirements
Input Voltage (VAC)
Input Power
Power Supply (VA)
90 to 240, 50 to 60 Hz
maximum typical
750 350
MATRIX 355 Datasheet
1 AVIA Ultra 2000 compatible beam parameters through internal beam expander (BE).
2 At specified rep. rate.

PaladinAdvanced355 DS

PaladinAdvanced355 DS

…From Standby (minutes) <15
From Cold Start (hours) <1
Static Alignment Tolerances2
Beam Position (mm) <±0.5 (x,y)
Beam Angle (mrad) <±2.5
Operating Voltage
Power Supply 90 to 230 VAC, 50 to 60 Hz
Power Consumption Maximum Operation (typical) Standby…

PaladinAdvanced355 Datasheet 2017.pdf

PaladinAdvanced355 Datasheet 2017.pdf

…355-16000 355-24000
Wavelength (nm) 355
Output Power1 (W) >8 >10 >16 >24
Repetition Rate (MHz) 80 ±1 80 ±1 80 ±1 82 ±1
Pulse Length (ps) >15 at 1064 nm
Spatial Mode TEM00
M2 <1.2
Beam Diameter (mm) 1 ±15% 1 ±15% 1.35 ±15% 1.35 ±15%
Beam…

COHR MATRIX355 DS 0317 2.pdf

COHR MATRIX355 DS 0317 2.pdf

…control
Input Power Requirements
Input Voltage (VAC) 90 to 240, 50 to 60 Hz
Input Power maximum typical
Power Supply (VA) 750 350
1 AVIA Ultra 2000 compatible beam parameters through internal beam expander (BE).
2 At specified rep. rate.
MATRIX 355 Datasheet

AVIA 355-28 DS

AVIA 355-28 DS

…at www.Coherent.com or contact your local Sales or Service Representative.
1 With Ophir-Spiricon M2-200s (measured at 90/10 knife edged, 2m from exit).
2 With Ophir-Spiricon SP620U and 3x beam reducer (measured at 90/10 knife edged, 1.0 m from exit).
Electrical Specifications

COHR PaladinCompact355 DS 0318 3.pdf

COHR PaladinCompact355 DS 0318 3.pdf

…Wavelength (nm) 355
Output Power (W)
Paladin Compact 355-2000 Air-Cooled
Paladin Compact 355-4000 Air-Cooled
>2
>4
Repetition Rate (MHz) 120 ±2
Pulse Length (ps) 15 at 1064 nm
Spatial Mode TEM00
M2 <1.2
Beam Diameter (mm) 1 ±10%
Beam…

COHR HRNX 355-30 HRR A4DS Japan 0419.pdf

COHR HRNX 355-30 HRR A4DS Japan 0419.pdf

…NX
355-30 HRR
(nm) 355

Amplifier
(kHz) 400 1000 800 2000
(kHz) 0 1000 0 2000
(ps) <15
(W) 30
7 (RMS 1,%) 1
(µJ) 75 37
8 (RMS 1, %) 2
(M²) 1.3
(1 m
(mm) 5.0 ±0.5
(
(mrad) 1
(1 m
(%) 85
(µrad/°

COHR HyperRapid100 355-SW DS 0716 6.pdf

COHR HyperRapid100 355-SW DS 0716 6.pdf

60 Hz
Head Weight 115 kg (253.5 lbs)
Repetition Rate (kHz) Average Power (W)
1064 nm 532 nm 355 nm
400 90 38 30
500 90 35 30
800 90 28 25
1000 90 23 20
Repetition Rate (kHz) Pulse Energy (µJ)
1064 nm 532 nm 355 nm
400 225 95 75
500 180 70 60