Search Results

Refine
1 - 8 of 8 Products for '405 50c' Page 1 of 1 |
  • 1

405 50c

COHR CUBE DS 0818 4.pdf

COHR CUBE DS 0818 4.pdf


405-100C
CUBE
445-40C
CUBE
488-50C
Part Number 1112774 1286998 1287002 1069418 1174040
Wavelength1 (nm) 375 405 405 445 488
Output Power2 (mW) 16 50 100 40 50
Beam Diameter at 1/e2 (mm) (typical) 1.1 1.4 1.4 1.1 1.3
Beam Divergence (mrad) (typical)…

CUBE Lasers

CUBE Lasers

…contact tech.sales@coherent.com. Part Name Description 1112774 CUBE 375-16C System, 375 nm, 16mW, Circular Beam (RoHS) 1142279 CUBE 405-100C System, 405 nm, 100mW, Circular Beam (RoHS) 1069418 CUBE 445-40C System, 445 nm, 40mW, Circular Beam (RoHS) 1174040 CUBE 488-50C System, 488 nm, 50mW, Circular…

2011-Diode-Laser-Modules-and-Pattern-Generators-Catalog.pdf

2011-Diode-Laser-Modules-and-Pattern-Generators-Catalog.pdf


12
CUBE
Diode Laser Systems
CUBE 375-16C 405-50C 405-100C
Part Number 1112774 1174298 1142279
Wavelength1 (nm) 375 405 405
Output Power2 (mW) 16 50 100
Beam Diameter at 1/e2 (mm)(typical) 1.1 1.4 1.4
Beam Divergence (mrad)(typical) 0.5 0.4 0.4
M2…

Lasers-for-Life-Sciences-Product-Guide FORMFIRST.pdf

Lasers-for-Life-Sciences-Product-Guide FORMFIRST.pdf

CUBE 375-16C 405-50C 405-100C
Part Number 1112774 1174298 1142279
Wavelength1 (nm) 375 405 405
Output Power2 (mW) 16 50 100
Beam Diameter at 1/e2 (mm)(typical) 1.1 1.4 1.4
Beam Divergence (mrad)(typical) 0.5 0.4 0.4
M2 (ModeMaster beam quality)3 <
_1.3 <

OBIS GalaxySystem Datasheet COHR 2018.pdf

OBIS GalaxySystem Datasheet COHR 2018.pdf

…Temperature
10 to 50°C (50 to 122°F)7
-20 to 60°C (-4 to 140°F)
Laser Safety Classification8 N/A
1 System specifications measured at 25°C.
2 All input channels require a ±1 nm center wavelength tolerance. Required wavelength tolerances specifically: 405 nm with 404 nm to 406…

OBIS Galaxy Datasheet COHR 2018.pdf

OBIS Galaxy Datasheet COHR 2018.pdf


10 to 50°C (50 to 122°F)7
-20 to 60°C (-4 to 140°F)
Laser Safety Classification8 Not Applicable
1 System specifications measured at 25°C.
2 All input channels require a ±1 nm center wavelength tolerance. Required wavelength tolerances specifically: 405 nm with 404…

COHR OBIS Galaxy DS 0519 3.pdf

COHR OBIS Galaxy DS 0519 3.pdf


10 to 50°C (50 to 122°F)7
-20 to 60°C (-4 to 140°F)
Laser Safety Classification8 Not Applicable
1 System specifications measured at 25°C.
2 All input channels require a ±1 nm center wavelength tolerance. Required wavelength tolerances specifically: 405 nm with 404…

compatibility matrix 02

compatibility matrix 02

…FieldMaxII-TO PM10 or PS10
*
Innova 90C 330 to 1090 nm FieldMaxII-TO PM10 or PS10
*
Laser Diode Modules
Stingray and BioRay Lasers 405 to 830 nm FieldMaxII-TO PS10
Mini Laser 635 to 830 nm FieldMaxII-TOP OP-2VIS
Tunable Lasers
MBR Ring Series 700 to 1030 nm FieldMaxII-TO…