Search Results

Refine

Result Type

1 - 7 of 7 Products for '48 V Power Supply' Page 1 of 1 |
  • 1

48 V Power Supply

Diamond J-3 Series OEM Lasers Preinstallation Manual, Rev. AC

Diamond J-3 Series OEM Lasers Preinstallation Manual, Rev. AC


power supply cable from the DC power supply is to be connected
directly to the marked connector on the rear panels, see Figure 3-16
on page 3-32. As in the case of the + 48 VDC connector, it is recommended that two wrenches be used to connect the - 48 VDC cable to
the - 48 V DC…

Diamond J-5 Series OEM Lasers Preinstallation Manual, Rev. AC


power supply cable from the DC power supply is to be connected
directly to the marked connector on the rear panels, see Figure 3-16
on page 3-30. As in the case of the + 48 VDC connector, it is recommended that two wrenches be used to connect the - 48 VDC cable to
the - 48 V DC…

COHR DC Series DS 0619web.pdf

COHR DC Series DS 0619web.pdf


ELECTRICAL RATINGS
Voltage 3 x 230 /400 V ± 10%, 3 x 255/440 V ±10% or 3 x 277 / 480 V ± 10%; 50/60 Hz; 3 Phases; PE
Connected Load (kVA) 48 56 60
Effective Power at Nominal Power (kW) 46 52 57
Max. Current Consumption at 400 V (A) < 70 < 81 < 87
Fuses Type NH…

Verdi preinstall.book

Verdi preinstall.book

…the
Power Supply
1. Move the power supply to an accessible-friendly location,
preferably away from heat producing sources. Ensure the
cooling intake and exhaust (front and back) are not blocked or
obstructed.
If storing the power supply in a 19 in. (48 cm) equipment…

00 E-1000 PreInst.book

00 E-1000 PreInst.book

…16. Place Laser System on Cart .............................................................................................. 34
17. RF Power Supply System Cable....................................................................................... 34
18. DIAMOND E-1000 Series System…

2011-Diode-Laser-Modules-and-Pattern-Generators-Catalog.pdf

2011-Diode-Laser-Modules-and-Pattern-Generators-Catalog.pdf

…Operating Temperature (°C) -10 to +48
Wavelength Drift (nm/°C) 0.25 typical
Thermal Stability Less than 5% change in focus over multiple temperature cycling
from 10°C to 30°C
Over-Temperature Protection (°C) Built-in: 48
Power Supply Voltage (VDC) 4.8 to 6.5 (6 optimal)…

Lasers-for-Life-Sciences-Product-Guide FORMFIRST.pdf

Lasers-for-Life-Sciences-Product-Guide FORMFIRST.pdf

…Laser
FAULT
GND
Coherent BioRay Laser
Power Supply
<
_30V
ILOAD
<
_100 mA
1 Lasers must have load applied to the modulation for proper operation.
Vmod
(V)
Nominal Power
0
0.1
0.2
0.3
0.4
0.5
0.6…