48 Vdc Power Supply

COHR Monaco UV DS 0619 3.pdf

COHR Monaco UV DS 0619 3.pdf

…(typical) 48 VDC, <500 W
Warranty 1-year, unlimited hours
1 All specifications at maximum pulse energy.
2 Measured 1 m ahead of laser front.
3 External isolation required depending on application.
4 External temp held to ±1°C.
5 Optional 110 to 240 VAC power supply

OBIS Power Supply

OBIS Power Supply

…and Power Supply
* Universal input connection (IEC-320)
* Compatible with 96-264 Volts AC input. Provides regulated 12 VDC output
* Cord length 1.2m (48 inches) Datasheet OBIS Single Laser Remote Drawing OBIS Single Laser Remote Power Supply Full-Feature Laser Remote and Power Supply - Universal…

00 E-250 Pre.book

00 E-250 Pre.book

48 VDC
power supply cable from the DC power supply is to be connected
directly to the marked connector on the rear panels, see Figure 3-15
on page 3-32. As in the case of the + 48 VDC connector, it is recommended that two wrenches be used to connect the - 48 VDC cable to
the - 48

Diamond J-5 Series OEM Lasers Preinstallation Manual, Rev. AC


When connecting the DC power supply's + 48 VDC cable to the
laser's + 48 RF filtering connector, use two wrenches to prevent
damaging the connector.
Never connect the DC supplies' cables to the laser with their
polarities reversed. Applying power under this condition will…

DIAMOND J-3 Series OEM Lasers Preinstallation Manual, Rev. AB

DIAMOND J-3 Series OEM Lasers Preinstallation Manual, Rev. AB

48 VDC
power supply cable from the DC power supply is to be connected
directly to the marked connector on the rear panels, see Figure 3-16
on page 3-32. As in the case of the + 48 VDC connector, it is recommended that two wrenches be used to connect the - 48 VDC cable to
the - 48

DIAMOND J-5 Series OEM Lasers Preinstallation Manual Rev AA

DIAMOND J-5 Series OEM Lasers Preinstallation Manual Rev AA

48 VDC
power supply cable from the DC power supply is to be connected
directly to the marked connector on the rear panels, see Figure 3-16
on page 3-32. As in the case of the + 48 VDC connector, it is recommended that two wrenches be used to connect the - 48 VDC cable to
the - 48

Diamond J-3 Series OEM Lasers Preinstallation Manual, Rev. AC

Diamond J-3 Series OEM Lasers Preinstallation Manual, Rev. AC

48 VDC
power supply cable from the DC power supply is to be connected
directly to the marked connector on the rear panels, see Figure 3-16
on page 3-32. As in the case of the + 48 VDC connector, it is recommended that two wrenches be used to connect the - 48 VDC cable to
the - 48

Diamond J-3-5 Series OEM Lasers Preinstallation Manual, Rev. AA

Diamond J-3-5 Series OEM Lasers Preinstallation Manual, Rev. AA

…earth ground be connected to the
negative terminal of the 48 VDC power supply. Please refer to
Figure 3-18.
WARNING!
Never connect a safety (earth) ground to the negative
DC terminal of the DC power supply. This terminal's potential
will rise above safety (earth) ground…

Diamond J-2 Series OEM Lasers Preinstallation Manual, Rev. AB


DC Power
Supply
A high current 48 VDC power supply is the required power source
for all J-2 Series laser systems.
Note that the laser presents a pulsed dynamic load to the DC power
supply. To observe the effect of laser modulation on the DC power
supply, connect an…

00 E-1000 PreInst.book

00 E-1000 PreInst.book

…when 48 VDC is applied to the RFPS terminals and
when the Connector Cable (Item 9) is connected.
8
48 VDC (+)
(terminal)
Connects +48 VDC from the DC power supply to the RF power supply.
Use a 3/4" wrench. Apply 190 lb.-in. (21.4 N·m) torque to nut supplied.
9…

00 E-400 E-1000 Series Preinstall.book

00 E-400 E-1000 Series Preinstall.book

…the RF power module and out to the drain.
From DC supply (+) Connects +48 VDC from the DC power supply to the RF power module. Apply
190 in.-lbs. (21.4 N·m) torque to nut supplied.
From DC supply (-) Connects the RF power module - 48 VDC return to the DC power supply. Apply

DIAMOND J-5V Series OEM Lasers Preinstallation Manual, Rev. AA

DIAMOND J-5V Series OEM Lasers Preinstallation Manual, Rev. AA

…and supplied in
the laser shipment while others must be obtained locally.
Table 3-3. Parts and Equipment Required for Installation
ITEM QUANTITY PURPOSE
AVAILABLE
FROM
COHERENT?
+ 48 VDC power
supply
1
Provides + 48 VDC power to the RF power module…

Please Read Before Continuing

Risk factors: Except for the historical information contained here, many of the matters discussed in this Web site are forward-looking statements, based on expectations at the time they were made, that involve risks and uncertainties that could cause our results to differ materially from those expressed or implied by such statements. These risks are detailed in the “Factors That May Affect Future Results” section of our latest 10-K or 10-Q filing. Coherent assumes no obligation to update these forward-looking statements.