Ask a Question
Coherent
Search Results
1 - 12 of 23 Products for '532 fiber coupled' Page 1 of 2 |

532 fiber coupled

Sapphire FP

Sapphire FP

…nm, 514 nm, 532 nm, 552 nm, 561 nm, 568 nm, 588 nm and 594 nm at output powers up to 200 mW. The Sapphire laser platform delivers a high quality, diffraction-limited beam (TEM00, M² < 1.1) with excellent pointing stability - a prerequisite for efficient and stable fiber coupling. Sapphire FP lasers…

Advances in Diode Lasers and OPSLs

Advances in Diode Lasers and OPSLs

…harmonic generation · Excellent beam and mode quality · High power stability & low noise · No "green problem" · No thermal lensing · Fiber coupling with high efficiency · High reliability & lifetime due to semiconductor design · Modulation capability: directly up to 100 kHz Optically…

(No Title Available)

(No Title Available)

…contain excellent beam quality and fast modulation response from 20 Watts to 120 Watts. Data Sheet DIAMOND C-20 Series HighLight FL-1000P All fiber lasers of the HighLight FL Series are characterized by maximum efficiency and service friendly, modular pumping units, helping to reduce operating…

Bio Photonics - OBIS Galaxy

Bio Photonics - OBIS Galaxy

…glass element. The light is then coupled into the output fiber that terminates in an FC/APC connector to enable simple connection into an experiment or instrument. The laser inputs span the visible spectrum and include legacy wavelengths such as 488, 514 and 532 nm, as well as the relatively new…

AVIA NX Family of Compact DPSS Lasers

AVIA NX Family of Compact DPSS Lasers

…Everything from the controller to the pump diodes is now integrated in a very compact laser head. This simplifies integration. And avoiding remote fiber coupled diodes also serves to eliminate possible failure points. Compact Size. AVIA NX lasers are far more powerful than any competitor and feature…

Bio Photonics - OBIS Galaxy

Bio Photonics - OBIS Galaxy

…glass element. The light is then coupled into the output fiber that terminates in an FC/APC connector to enable simple connection into an experiment or instrument. The laser inputs span the visible spectrum and include legacy wavelengths such as 488, 514 and 532 nm, as well as the relatively new…

Bio Photonics - November 2014

Bio Photonics - November 2014

…glass element. The light is then coupled into the output fiber that terminates in an FC/APC connector to enable simple connection into an experiment or instrument. The laser inputs span the visible spectrum and include legacy wavelengths such as 488, 514 and 532 nm, as well as the relatively new…

250 kHz Ultrafast Amplifiers

250 kHz Ultrafast Amplifiers

…Optical Fiber & Assemblies Bend Insensitive Fiber Select Cut-Off and Standard Single-Mode Fiber Polarization Maintaining Fiber CO 2 and CO Lasers Genesis Lasers Genesis CX-Series Genesis MX-Series OBIS LX/LS Accessories Sapphire Lasers Industrial Fiber & Diode Lasers Fiber Coupled Laser Diodes…

Genesis MX-Series

Genesis MX-Series

…comes with an optional temperature controller and/or power supply. Additional accessories include air or water-cooling, collimator, or shutter. Fiber coupling is available with the MX MTM OEM head only. The MX end user system is turn-key, CDRH and CE compliant, and comes complete with a front-panel…

Bio Photonics - November 2014

Bio Photonics - November 2014

…glass element. The light is then coupled into the output fiber that terminates in an FC/APC connector to enable simple connection into an experiment or instrument. The laser inputs span the visible spectrum and include legacy wavelengths such as 488, 514 and 532 nm, as well as the relatively new…

Bio Photonics - OBIS Galaxy

Bio Photonics - OBIS Galaxy

…glass element. The light is then coupled into the output fiber that terminates in an FC/APC connector to enable simple connection into an experiment or instrument. The laser inputs span the visible spectrum and include legacy wavelengths such as 488, 514 and 532 nm, as well as the relatively new…

Bio Photonics - November 2014

Bio Photonics - November 2014

…glass element. The light is then coupled into the output fiber that terminates in an FC/APC connector to enable simple connection into an experiment or instrument. The laser inputs span the visible spectrum and include legacy wavelengths such as 488, 514 and 532 nm, as well as the relatively new…

Powered by Site Search powered by SLI Systems

Call 1-800-227-8840


Outside the U.S. 1-408-764-4983

Coherent has locations across the globe that are available to provide support for any product, service or inquiry.

Visit our Contact Page to connect with any of our global sites.


Corporate Headquarters
Coherent Inc.
5100 Patrick Henry Drive
Santa Clara, CA 95054 USA

email: tech.sales@coherent.com

Send Us a Message

Please Read Before Continuing

Risk factors: Except for the historical information contained here, many of the matters discussed in this Web site are forward-looking statements, based on expectations at the time they were made, that involve risks and uncertainties that could cause our results to differ materially from those expressed or implied by such statements. These risks are detailed in the “Factors That May Affect Future Results” section of our latest 10-K or 10-Q filing. Coherent assumes no obligation to update these forward-looking statements.


I have read the terms and conditions