Search Results

1 - 12 of 15 Products for 'Air Purge' Page 1 of 2 |

Air Purge

DIAMOND J-5 Series OEM Lasers Preinstallation Manual Rev AA

DIAMOND J-5 Series OEM Lasers Preinstallation Manual Rev AA

…and Troubleshooting in the operator's manual for the
routine maintenance required for the purge gas filters.
Figure 3-5. Air Filter Dryer Unit
AIR OUT
1 2
1. Air Purge Filter Assembly; Part Number: 1232642
2. Replacement Desiccant Filter Cartridge; Part Number:…

DIAMOND J-3 Series OEM Lasers Preinstallation Manual, Rev. AB

DIAMOND J-3 Series OEM Lasers Preinstallation Manual, Rev. AB

…has identified a suitable dry air purge filter which filters to
0.1 microns and dries the air to a dew point of - 40°C (- 40°F). The
filter is shown in Figure 3-5 and is widely available.
For additional information on the Air Filter Dryer Unit, refer to "Air
Filter Dryer Unit" on…

COHR DIAMOND J-3-5 COlaser DS 0617 2.pdf

COHR DIAMOND J-3-5 COlaser DS 0617 2.pdf

…drop from chiller fittings and the supply and return hose.
11 Do not operate at or below dew point.
12 Clean dry air or nitrogen are acceptable as purge gases. Coherent can recommend suitable commercial gas filter/dryers.
13 Measured at 1 kHz, 300 s RF pulse width.
Diamond…

00 E-250 Pre.book

00 E-250 Pre.book

…tubing to carry the purge gas.
Failure to comply with these specifications will void the
warranty and the customer is responsible for all cost of repair or
damage to the laser.
Figure 3-4. Air Filter Dryer Unit
AIR OUT
1 2
1. Air Purge Filter Assembly; Part…

AVIA NX nanosecond laser | Coherent

AVIA NX nanosecond laser | Coherent

…and made it even better. These Gen 4 lasers are designed, built and tested to deliver maximum uptime. While the competition still uses legacy air purging to try and keep their optics clean, proprietary innovations in AVIA NX like our PureUV™ active laser cleaning engine mean the laser is truly…

00 E-400 E-1000 Series Preinstall.book

00 E-400 E-1000 Series Preinstall.book

…identified a suitable dry air purge filter which filters to
0.1 microns and dries the air to a dew point of -40°C (-40°F). The
filter is shown in Figure 5 and is widely available.
For additional information on the Purge Filter/Dryer Assembly, refer
to the "Air Filter Dryer Unit"…

00 LMT Pre.book

00 LMT Pre.book

…Sensor
Input
Outlet to Chiller
Remote Interlock
Remote Fan
Regulator Vent
Inlet from Chiller
Control Air Input
Laser Purge Gas
Input
Relay
Pin 1: N.O. Relay Contact
Pin 2: Relay Contact Common
Pin 3: Shield
1
3
2

00 E-1000 PreInst.book

00 E-1000 PreInst.book


described above or compressed air as described below should be
used as a purge gas.
Guidelines for Use of
Compressed Air for
Purge
If nitrogen is not available, the alternative is clean, dry, oil-free
compressed air. Compressed air is available in many facilities…

MetaBEAM1000c Pre.book

MetaBEAM1000c Pre.book

…[ ] 15 kW (51 kBTU/h) cooling
capacity
[ ] Distilled and 10% corrosion
inhibitor coolant composition
Clean, Dry Air (CDA): CDA is used to purge the cutting head
optics and control the pneumatic table locks and front and rear
pallet doors. Review this manual for CDA…

00 Sabre Preinstall.book

00 Sabre Preinstall.book

…with the deep or short UV options
include purge kits. The purge kit consists of a variable flowmeter,
necessary connectors and hoses, and special intracavity parts. A
user-supplied source of dry nitrogen is required on purged systems.
The recommended grade of bottled nitrogen…

00 SabreMFreD Preinstall.book

00 SabreMFreD Preinstall.book

…contact with other equipment.
All Innova Sabre MotoFreD ion laser systems include purge kits for
dry nitrogen because of the hygroscopic nature of the BBO
frequency doubling crystal. The purge kit consists of a variable
flowmeter, necessary connectors and hoses, a particulate…

COHR AVIA NX Green DS 0818 3.pdf

COHR AVIA NX Green DS 0818 3.pdf

…MECHANICAL SPECIFICATIONS
Rotatable
Output Window
Laser Beam
Coolant In
Coolant Out
Laser Beam
Output Window
Purge Inlet
Laser Beam
76.4 mm
(3.01 in.)
86.5 mm
(3.41 in.)
173.0 mm
(6.81 in.)
96.0 mm
(3.78 in.)

Please Read Before Continuing

Risk factors: Except for the historical information contained here, many of the matters discussed in this Web site are forward-looking statements, based on expectations at the time they were made, that involve risks and uncertainties that could cause our results to differ materially from those expressed or implied by such statements. These risks are detailed in the “Factors That May Affect Future Results” section of our latest 10-K or 10-Q filing. Coherent assumes no obligation to update these forward-looking statements.


I have read the terms and conditions