Search Results

1 - 12 of 32 Products for 'Argon' Page 1 of 3 |

Argon

Ion Lasers

Ion Lasers

…the following, a Coherent ion laser may be the right solution for your application:
* Continuous wave radiation at one or more of the available Argon or Krypton transitions which span the spectrum from the UV to the IR
* Relatively high spectral purity
* Multi-watt output at any number of different…

INNOVA 90C

INNOVA 90C

…0.30 0.35 0.42 - 454.5 - 0.05 0.12 0.14 - 406.7-415.4 - - - - 0.15 337.5-356.4 - - - - 0.15 333.6-363.8 - 0.20 0.30 0.50 - Beam Specifications 2 Argon Krypton Beam Diameter (@ 1/e 2 points)3 1.5 mm 1.5 mm Beam Divergence (full angle) 0.5 mrad 0.8 mrad Beam Waist Diameter 4 1.4 mm 1.1 mm Beam Waist…

INNOVA 70C Ion Laser | Coherent

INNOVA 70C Ion Laser | Coherent

…514.5 nm for argon lasers and 47.1 nm for krypton lasers. 3 Beam diameter is measured at the output-coupler mirror. 4 Maximum peak variation over any 30 minute period after a 2-hour warm-up. 5 Measured with a 10 Hz to 2 MHz photodiode driving a resistive load at 514.5 nm for argon systems and 647.1…

INNOVA Sabre Laser | Coherent

INNOVA Sabre Laser | Coherent

…Lithography Photographic Film Photoresist Dye Laser Ti:Sapphire Laser Plastic Paper Fluorescence Excitation --> Features & Benefits Argon DBW Innova Sabre Argon System with Dual Brewster Window (DBW) Tubes Power Specifications 1 Wavelength (nm) DBW10 DBW15 DBW20 DBW25 Multiline Visible 10.0…

Mira Family

Mira Family

…pumping ensures the highest power stability and lowest noise ultrafast performance commercially available. Mira may also be pumped by Coherent’s argon ion laser systems. X-Wave Optics Operation is greatly simplified by the use of Coherent’s X-Wave optics. No optics changes are required as this…

00 E-1000 PreInst.book

00 E-1000 PreInst.book

…make certain the supply and supply line
is properly sized to provide an adequate flow rate to the laser system.
Other inert gases such as argon (Ar) must not be used. Use of
inert gases will result in damage to the RF power supply and
associated matching network components. Only…

INNOVA 300C Laser

INNOVA 300C Laser

…0.25 I-310 Argon Systems with Sealed Mirror - Visible Region Multiline Visible 2 10.0 I-324 I-325 I-326 I-328 Argon Systems with Sealed Mirror - UV Region Multiline UV 3 0.20 0.40 0.50 1.00 UV 363.8 0.07 0.14 0.18 0.36 UV 351.1 0.09 0.18 0.22 0.44 I-304 I-305 I-306 I-307 I-308 Argon Single Frequency…

Life Sciences and Medical Applications

Life Sciences and Medical Applications

…Coherent offers the Sapphire SF single-frequency OPSL series with wavelengths at 488 nm and 532 nm. The Innova 300C and 70C series of small-frame argon or krypton ion lasers are also well suited for Raman experiments in the visible region of the spectrum. Innova 70C Spectrum is a mixed gas lasers…

Microelectronics

Microelectronics

…area flat field illumination. Direct write. This requires a controlled TEM00 beam and as deep UV as possible. This can be either a frequency doubled Argon Laser (FreD) or a frequency doubled solid-state green laser such as Azure. Unfortunately, it is difficult to test these optical components with a…

Quotation KML QGYYMMDD G  Institute Contact

Quotation KML QGYYMMDD G Institute Contact

…laser
Value
Photon Flux at 35 nm (Argon)
--at the source
1.2x1011
photons/sec/harmonic
Photon Flux at 13.5 nm (Helium)
--at the source
1.5x107
photons/sec/harmonic
Spectral range 11 nm to 50 nm (Argon)
25 eV to 112 eV (Helium)
Beam Pointing…

Laser Focus World - August 2016

Laser Focus World - August 2016

…came to dominate flow cytometry
in the 1980s. Over time, however, the
ongoing evolution of highly reliable and
compact air-cooled argon lasers enabled
construction of smaller (though still massive compared with today's offerings) and
less-expensive cytometers. These…

Advances in Diode Lasers and OPSLs

Advances in Diode Lasers and OPSLs

…whitepaper compares these technologies and shows why the end of these venerable gas lasers is finally at hand. The Pros and Cons of Gas Lasers Ion (argon, krypton) and HeCd lasers generally produce a high quality beam, with TEM00 output and a M2 approaching the best value of 1.0. For applications…

Please Read Before Continuing

Risk factors: Except for the historical information contained here, many of the matters discussed in this Web site are forward-looking statements, based on expectations at the time they were made, that involve risks and uncertainties that could cause our results to differ materially from those expressed or implied by such statements. These risks are detailed in the “Factors That May Affect Future Results” section of our latest 10-K or 10-Q filing. Coherent assumes no obligation to update these forward-looking statements.


I have read the terms and conditions