Search Results

Refine
1 - 7 of 7 Products for 'Attenuator Module Motorized' Page 1 of 1 |
  • 1

Attenuator Module Motorized

COHR AttenuatorModule DS 0320 2.pdf

COHR AttenuatorModule DS 0320 2.pdf

Attenuator Module Datasheet
SPECIFICATIONS Manual Attenuator Module Motorized Attenuator Module
Clear Aperture1 42 x 22 mm (1.65 x 0.87 in.)
Beam Height 90 mm (3.54 in.)
Transmission Range (%)
248/308/351 nm Wavelengths
157/193 nm Wavelengths
10 to 90
10 to 70…

UV Optical Components

UV Optical Components

…Electromagnetic shutter. Attenuator Module, Motorized Variable attenuation substrate 60 x 35 x 2 mm 3 with inverse characteristic for high thermal stability. Compensator plate 60 x 35 x 2 mm 3 to compensate for any beam displacement. With DC motor and encoder, ACM RS-232 interface module, interface…

COHR ExcimerCatalog2019.pdf

COHR ExcimerCatalog2019.pdf

…shutter
Attenuator Module, Motorized
- Variable attenuation substrate 60 x 35 x 2 mm3 with inverse characteristic for high thermal stability
- Compensator plate 60 x 35 x 2 mm3 to compensate for any beam displacement
- DC motor and encoder, ACM RS-232 interface module, interface…

Excimer laser technology trends

Excimer laser technology trends


external attenuation using a dual plate attenuator.
Attenuator modules, as depicted in figure 3, left, are either
controlled manually or motorized with feedback diode and are
increasingly used as a convenient add-on in PLD labs.
Dual plate attenuators work via two…

COHR ExcimerCatalog2020 final lr.pdf

COHR ExcimerCatalog2020 final lr.pdf

…shutter
Attenuator Module, Motorized
- Variable attenuation substrate 60 x 35 x 2 mm3 with inverse characteristic for high thermal stability
- Compensator plate 60 x 35 x 2 mm3 to compensate for any beam displacement
- DC motor and encoder, ACM RS-232 interface module, interface…

COHR ExcimerCatalog2020 int 0320.pdf

COHR ExcimerCatalog2020 int 0320.pdf

…shutter
Attenuator Module, Motorized
- Variable attenuation substrate 60 x 35 x 2 mm3 with inverse characteristic for high thermal stability
- Compensator plate 60 x 35 x 2 mm3 to compensate for any beam displacement
- DC motor and encoder, ACM RS-232 interface module, interface…

Biosafety Level 3 setup for multiphoton microscopy in vivo

Biosafety Level 3 setup for multiphoton microscopy in vivo

…excitation
light source for conventional MPM. The beam control (BeamOptimizer, Lavision BioTec) uses a polarizer/analyzer as attenuation and an electro optical Modulator for fast beam switching for line blanking and phototreatment applications. A telescope adapts the beam diameter for the…