Search Results

1 - 11 of 11 Products for 'Avia 355 30' Page 1 of 1 |
  • 1

Avia 355 30

AVIA 355-28 DS

AVIA 355-28 DS

STACCATO
Wavelength (nm)(center) 1030 ±2
Average Power (W) >
_2.4 at 80 kHz
Pulse Energy (µJ) >
_30
Pulse Duration t (FWHM, sech2) 1300 fs <
_t <
_ 2000 fs
Pulse Energy Stability (%)(Peak-to-Peak over 1000 Pulses) <
_5 RMS (1s)

COHR AVIA NX UV DS 0117 5.pdf

COHR AVIA NX UV DS 0117 5.pdf

…Specifications
Temperature -20 to +60°C (-4 to 140°F)
Relative Humidity (%) 5 to 80
AVIA NX 355-30, 355-25 and 355-20 Spec UV Performance
0
5
10
15
20
25
30
35
0
50
100
150
200
250
300
350
0

AVIA LX Solid State Q-Switched UV Laser

AVIA LX Solid State Q-Switched UV Laser

AVIA LX Datasheet
SPECIFICATIONS AVIA LX 355-20-50 AVIA LX 355-20-100 AVIA LX 355-20-40 HE
1.5 SB 3.0 SB 1.5 SB 3.0 SB 1.5 SB 3.0 SB
Output Power (W) (specified) >20 at 50 kHz >20 at 100 kHz >20 at 40 kHz
Output Power (W) (typical) >15 at 100 kHz
>10 at 150…

COHR MATRIX355 DS 0317 2.pdf

COHR MATRIX355 DS 0317 2.pdf

…control
Input Power Requirements
Input Voltage (VAC) 90 to 240, 50 to 60 Hz
Input Power maximum typical
Power Supply (VA) 750 350
1 AVIA Ultra 2000 compatible beam parameters through internal beam expander (BE).
2 At specified rep. rate.
MATRIX 355 Datasheet

COHR MATRIX355 DS 1118 1.pdf

COHR MATRIX355 DS 1118 1.pdf

…Input Power Requirements
Input Voltage (VAC)
Input Power
Power Supply (VA)
90 to 240, 50 to 60 Hz
maximum typical
750 350
MATRIX 355 Datasheet
1 AVIA Ultra 2000 compatible beam parameters through internal beam expander (BE).
2 At specified rep. rate.

compatibility matrix 02

compatibility matrix 02

…Solid-State (pulsed)
AVIA (< 10 W) 266, 355 nm FieldMaxII-TO PM10X
AVIA (10 to 30 W) 355, 532 nm FieldMaxII-TO PM30X
AVIA NX (> 30 W) 355, 532 nm FieldMaxII-TO PM150
Daytona (discontinued 2014) 355 nm FieldMaxII-TO PM30X
Flare 355, 532, 1064 nm LabMax-TOP J-10MB-HE…

GUI 3.88 Revision History.pdf

GUI 3.88 Revision History.pdf

…the AVIA LX service triggering tab
AVIA LX:#303 - Store power meter readings in the laser if the laser supports this
Resolves AVIA LX:#291 - Add AVIA LX link to "Visit AVIA webpage" button
Resolves AVIA LX:#298 - Don't display seconds on charts in Singapore
Resolves AVIA LX:#149…

COHERENT LMC 2016-2017 Catalog .pdf

COHERENT LMC 2016-2017 Catalog .pdf

…Power Sensor
AVIA (<10W) 266, 355 FieldMaxII-TO PM10X
AVIA (10W to 30W) 355, 532 FieldMaxII-TO PM30X
AVIA (>30W) 532 FieldMaxII-TO PM150
Mamba Green, IR 532, 1064 FieldMaxII-TO PM1K
MATRIX 532, 1064 532, 1064 FieldMaxII-TO PM30
MATRIX 355 355 FieldMaxII-TO PM10X…

2009 LMCCatalog86.pdf

2009 LMCCatalog86.pdf

…PM30
Laser Wavelength (nm) Power Meter Power Sensor Energy Meter Energy Sensor
AVIA (<10W) 266, 355 FieldMaxII-TO PM10X - -
AVIA (10W to 30W) 355, 532 FieldMaxII-TO PM30X - -
AVIA (>30W) 532 FieldMaxII-TO PM150 - -
Indigo-DUV 193 FieldMaxII-TO PS10 3sigma J-10MT-10KHZ…

COHR PowerLine AVIANX DS 0519.pdf

COHR PowerLine AVIANX DS 0519.pdf

AVIA NX 20-355 AVIA NX 40-355
Laser Wavelength (nm) 354.7
Average Power (W) 20 40
Pulse Repetiton Rate (kHz) 1 to 250 1 to 300
Beam Quality M2 <1.3
Pulse-to-Pulse Stability (% rms) <5
Pulse Energy (µJ) 200 at 100 kHz 308 at 130 kHz
Pulse Width (ns) <30 (up…

COHR PowerMax-Pro DS 0917 3.pdf

COHR PowerMax-Pro DS 0917 3.pdf

…Lasers of this type within the Coherent portfolio include the Matrix QS, Avia NX, Flare NX, Helios (the
regular "HD" models are not appropriate for these short pulsed, high energy lasers).
2 Contact Coherent for 355nm usage guidelines.
3 Water flow rate for water-cooled sensors must…