…Laser Beam Profiler, Laser Beam Analyzer and Laser Beam Propagation.
* ModeMaster PC M-Squared (M2) Beam Propagation Analyzer - For measuring M2 and other beam analysis functions for CW lasers.
* LaserCam-HR Family - Two New LaserCam products joining an already successful LaserCam-HR camera.
*…
--> LaserCam-HR-InGaAs High-resolution SWIR laser beam profiling system for applications in the 900 nm to 1700 nm wavelength range. This 14-bit, large area, uncooled InGaAs camera provides user programmable integration and incredibly fast capture rates with an optical dynamic range of greater than…
…(intensity profile). Beam Profile vs. Beam Propagation Beam profilers measure the spatial intensity distribution of a laser beam. However, no matter how accurately and diligently a profile is measured, this information does not predict the intensity distribution elsewhere along the beam path. If the…
…II beam diagnostics cameras use laser-grade
1/2-inch and 2/3-inch CCD sensors for detection and analysis of
laser beam profiles from ~150 micron to 4 mm in diameter (1/2-inch
camera) and ~150 micron to 6 mm in diameter (2/3-inch camera).
The 1/2-inch model is a 12-bit camera with…
…cameras that provide greater dynamic range and lower noise than the previous generation, as well as a UV laser beam profiling system for applications from 190 nm to 355 nm. This UV model is robust when used with the harsh UV wavelengths that often degrade typical beam diagnostic cameras. The cameras…
…available for direct sales between Coherent and end customers (non-OEM), and is good for up to four units (e.g. one meter, two of sensors, and a camera; or two meters and two sensors, etc.). PRICE HERE Close (applicable to direct sales to Coherent customers, limited quantities.) Download the matrix…
…help. Email: lmc.sales@coherent.com Phone: (800) 527-3786 PRICE HERE Close C24 Program Products Beam Diagnostic Cameras LaserCam-HR II - 1/2” USB Camera System (RoHS) LaserCam-HR II - 2/3” USB Camera System (RoHS) DB25 Energy Sensors J-10MB-HE J-10MB-LE J-10MT-10KHZ J-25MB-HE J-25MB-LE J-25MT-10KHZ…
…these reflected beams in a configuration called a Mach-Zehnder interferometer. The recombined
beam is then expanded and viewed using a CCD camera.
If the OPSL chip remains flat with no thermal lensing, then the image at the camera would be
uniform across its profile. Conversely, any…
…specification.
Beams with a very small divergence, i.e. with an almost constant beam diameter over a significant propagation
distance are generally called "collimated beams".
To measure divergence correctly with a camera based beam analyzer (profiler), a lens or confocal mirror…
…a line beam with
a long-axis homogeneity of below 2% of the two-sigma
confidence interval is achieved along the entire line length.
Optionally, the LLO systems feature a CCD (Charge Coupled Device) beam profiler camera for measuring the line
beam profile at the substrate…
…Software
BeamView-USB 106-111
Beam Diagnostic Accessories
Laser Grade Attenuation Optics for Cameras 112
Attenuation Optics for Cameras 113
Extreme-UV Beam Intensity Profile Optics 114
BeamMaster
Knife-Edge Based Beam Profilers 115-116
BeamMaster Accessories…
…camera-based beam-profiler systems as well as knife-edge-based scanning systems. The
cameras are targeted at customers wanting fast analysis of the
spatial profile of pulsed or CW laser beams; they can often be
found in production lines, incoming/outgoing inspection, and
R&D…