Search Results

1 - 10 of 10 Products for 'Boresight' Page 1 of 1 |
  • 1

Boresight

Laser Diode Modules

Laser Diode Modules

…range for standard options
* Largest installed base of Machine Vision Lasers
* Highest reliability and best industry warranty - 24 months.
* Uniformity – Down to +/- 1%
* Straightness = 75% of normalized intensity
* Boresight = 75% of normalized intensity Boresight <= 3 mrad, Pointing <= 10 urad/C

HYPER RAPID Lasers

HYPER RAPID Lasers

…<50 Electric Supply 100 to 230 VAC/50 to 60 Hz/2.5 kW 100 to 230 VAC/50 to 60 Hz/2.5 kW Beam Diameter (μm) ~3000 at 1064 nm ~3000 at 1064 nm Bore-Sight Accuracy ±0.5 mm and <5 mrad Warm-Up Time <40 min from chiller start High Power Industrial Picosecond Laser - The HYPER RAPID family of high power…

Properties-of-Structured-Light-Application-Note.pdf

Properties-of-Structured-Light-Application-Note.pdf


Bore-sight & Fan Angle
The "curved" profile (see Figure 9) is caused by the angle
between the lens and the incident beam. This curvature can be
expressed as (dx/L) x 100 (see Figures 11 and 12).
A general rule of thumb is:
Curvature (%) = Fan Angle () x Boresight

2011-Diode-Laser-Modules-and-Pattern-Generators-Catalog.pdf

2011-Diode-Laser-Modules-and-Pattern-Generators-Catalog.pdf

…conventional crosshairs that are formed either by using two lasers or by splitting and
recombining one beam to form a cross.
4 Define boresight method.
Reverse
TTL
Modulation
Vmod (V)
0 1 2 3 4 5
Direct
TTL
Modulation
Optical Power

COHR StingRay BioRay DS 0618 3.pdf

COHR StingRay BioRay DS 0618 3.pdf

…Mode)
Beam Quality, M2 (ModeMaster with 90/10 Clip Level) <1.5
Pointing Stability over Temperature (µrad/°C) <10
Beam Angle (boresight) (mrad) <3
RMS Noise (%) (20 Hz to 20 MHz) <0.5
Peak-to-Peak Noise (%) (20 Hz to 20 MHz) <1
Long Term Power Stability…

HYPERRAPID100 DS 0414 5.pdf

HYPERRAPID100 DS 0414 5.pdf

…Stability in Full PRF Range (rad/°C) <50
Electric Supply1 100 to 230 VAC/50 to 60 Hz/3.6 kW
Beam Diameter (m) ~3000 at 1064 nm
Bore-Sight Accuracy ±0.5 mm and <5 mrad
Warm-Up Time (minutes) <40 from chiller start
Repetition Rate (kHz) Average Power (W)
No AOM…

COHR HyperRapid50 DS 0716 4.pdf

COHR HyperRapid50 DS 0716 4.pdf

…Beam Divergence, Full Angle (mrad) <1
Beam Circularity1 (%) >85
Beam Pointing Stability in Full PRF Range (µrad/°K) <50
Bore-sight Accuracy ±0.5 mm and <5 mrad
Warm-up Time (minutes) <40
Electric Supply2 230 VAC for 3.5 kW/50 to 60 Hz
Head Weight 115 kg…

COHR HyperRapid100 355-SW DS 0716 6.pdf

COHR HyperRapid100 355-SW DS 0716 6.pdf

…Beam Divergence, Full Angle (mrad) <1
Beam Circularity (%) >85
Beam Pointing Stability in Full PRF Range (µrad/°K) <50
Bore-sight Accuracy ±0.5 mm and <5 mrad
Warm-up Time (minutes) <40
Electric Supply 230 VAC for 1.6 kW/50 to 60 Hz
Head Weight 115 kg…

COHR StingRay BioRay DS 0119 3.pdf

COHR StingRay BioRay DS 0119 3.pdf

…Mode)
Beam Quality, M2 (ModeMaster with 90/10 Clip Level) <1.5
Pointing Stability over Temperature (µrad/°C) <10
Beam Angle (boresight) (mrad) <3
RMS Noise (%) (20 Hz to 20 MHz) <0.5
Peak-to-Peak Noise (%) (20 Hz to 20 MHz) <1
Long Term Power Stability…

book.book

book.book

…Mode
TEM00
(Single Transverse
Electric Mode)
Pointing Stability over Temperature (rad/°C) <10 rad/°C
Beam Angle (boresight) (mrad) <3 mrad
RMS Noise (%) (20 Hz to 20 MHz) <0.5%
Peak-to-Peak Noise (%) (20 Hz to 20 MHz) <1%