Cabinet

HighLight FL-Series

HighLight FL-Series

…is optionally available enabling simple implementation of scanner-based applications. The “compact” version with a spliced fiber and a small cabinet is ideally suited for easy integration into existing systems. One of the latest advancements is the new HighLight FL3000C with 3 kW output power…

DC Series

DC Series


* Head/cabinet combination – with wall mountable, space-saving control cabinet (45% space-saving) and optional touchpanel on the control cabinet for easy operation.
* Compact version – laser head and control cabinet in one compact unit. Due to the closed beam path, the lasers of this Series…

Incoupling Optics

Incoupling Optics

…fiber. Certified safety concept Laser safety is fundamental for all Optoskand incoupling optics. The integrated electronics monitor fiber breakage, cabinet doors, mirror positions, etc. The DGUV-certified safety electronics makes it easier to integrate our components in industries demanding a high…

arm A4 4s 0906.pdf

arm A4 4s 0906.pdf

…FIBER Fiber optic cable QBH/QD Fiber Length 20m INTERFACES Digital I/O,Analog control, Ethernet COOLING Flow (liter/minute) 75-130 Cooling water temperature +25 ± 1 °C DIMENSIONS H x W x D [mm] 830 x 800 x 903 or 1328 x 800 x 903 OPTIONS Optics External optics (Optoskand) Cabinet air conditioner

COHR HighLight FL-ARM DS 0617 2.pdf

COHR HighLight FL-ARM DS 0617 2.pdf

…x W x D) 830 x 800 x 903 mm (32.7 x 31.5 x 35.6in.) or 1328 x 800 x 903 mm (52.3 x 31.5 x 35.6 in.) Options Optics External optics (Optoskand) Cabinet Air Conditioner HighLight FL-ARM Datasheet ARM TECHNOLOGY ARM is a patented technology that creates dynamic ringmode which can be adjusted on-the-fly…

COHR HighLight FL-ARM DS 0617 2.pdf

COHR HighLight FL-ARM DS 0617 2.pdf

…x W x D) 830 x 800 x 903 mm (32.7 x 31.5 x 35.6in.) or 1328 x 800 x 903 mm (52.3 x 31.5 x 35.6 in.) Options Optics External optics (Optoskand) Cabinet Air Conditioner HighLight FL-ARM Datasheet ARM TECHNOLOGY ARM is a patented technology that creates dynamic ringmode which can be adjusted on-the-fly…

DC Series 03-2017 E.pdf

DC Series 03-2017 E.pdf

…integration package or head/ cabinet combination Highest electrical and optical safety levels according to EN/ISO 13849-1/2 ROFIN Control Unit (RCU) with improved pulsing capabilities, manifold control and log functions including E-Service Wall-mountable control cabinet with a small footprint THE…

COHR LEAPseries DS 0916 1.pdf

COHR LEAPseries DS 0916 1.pdf

…pulses) 30 30 30 30 Electrical (kVA) 8.6, 3-phase, 200/208 or 400 VAC, 50/60 Hz Water Cooling 20 l/min.;T = 19 to 21°C Weight 860 kg (1896 lbs.) Cabinet Size (L x W x H) 2415 x 800 x 1090 ±10 mm3 (95.1 x 31.4 x 42.9 ±o.4 in.3) High Duty Cycle Excimer Lasers LEAP Series LEAP Excimer Laser Operation…

COHR LEAPseries DS 0916 1.pdf

COHR LEAPseries DS 0916 1.pdf

…pulses) 30 30 30 30 Electrical (kVA) 8.6, 3-phase, 200/208 or 400 VAC, 50/60 Hz Water Cooling 20 l/min.;T = 19 to 21°C Weight 860 kg (1896 lbs.) Cabinet Size (L x W x H) 2415 x 800 x 1090 ±10 mm3 (95.1 x 31.4 x 42.9 ±o.4 in.3) High Duty Cycle Excimer Lasers LEAP Series LEAP Excimer Laser Operation…

COHR LEAPseries DS 0916 1.pdf

COHR LEAPseries DS 0916 1.pdf

…pulses) 30 30 30 30 Electrical (kVA) 8.6, 3-phase, 200/208 or 400 VAC, 50/60 Hz Water Cooling 20 l/min.;T = 19 to 21°C Weight 860 kg (1896 lbs.) Cabinet Size (L x W x H) 2415 x 800 x 1090 ±10 mm3 (95.1 x 31.4 x 42.9 ±o.4 in.3) High Duty Cycle Excimer Lasers LEAP Series LEAP Excimer Laser Operation…

Biosafety Level 3 setup for multiphoton microscopy in vivo

Biosafety Level 3 setup for multiphoton microscopy in vivo

www.nature.com/scientificreports/ 3Scientific RepoRts | 7: 571 | DOI:10.1038/s41598-017-00702-x Figure 1. Class III Biosafety Cabinet for inverted and upright multiphoton microscope. (a) The ventilator unit extracts room air that is HEPA filtered and pulsed into to the heating module before reaching…

Biosafety Level 3 setup for multiphoton microscopy in vivo

Biosafety Level 3 setup for multiphoton microscopy in vivo

www.nature.com/scientificreports/ 3Scientific RepoRts | 7: 571 | DOI:10.1038/s41598-017-00702-x Figure 1. Class III Biosafety Cabinet for inverted and upright multiphoton microscope. (a) The ventilator unit extracts room air that is HEPA filtered and pulsed into to the heating module before reaching…

Powered by Site Search powered by SLI Systems

Call 1-800-227-8840


Outside the U.S. 1-408-764-4983

Coherent has locations across the globe that are available to provide support for any product, service or inquiry.

Visit our Contact Page to connect with any of our global sites.


Corporate Headquarters
Coherent Inc.
5100 Patrick Henry Drive
Santa Clara, CA 95054 USA

email: tech.sales@coherent.com

Send Us a Message

Please Read Before Continuing

Risk factors: Except for the historical information contained here, many of the matters discussed in this Web site are forward-looking statements, based on expectations at the time they were made, that involve risks and uncertainties that could cause our results to differ materially from those expressed or implied by such statements. These risks are detailed in the “Factors That May Affect Future Results” section of our latest 10-K or 10-Q filing. Coherent assumes no obligation to update these forward-looking statements.


I have read the terms and conditions