Search Results

1 - 12 of 131 Products for 'Calibration' Page 1 of 11 |

Calibration

LabMax-Pro SSIM User Manual

LabMax-Pro SSIM User Manual

…PowerMax-Pro Sensors (Normalized to Calibration
Wavelength)
Table 2-1. Wavelength Compensation Accuracya
a. Refers to wavelengths different from the calibration wavelength.
Sensor
Wavelength Compensation
Accuracy
Calibration
Wavelength (nm)
All PM model…

Understanding ISO 17025 for Laser Power and Energy Measurement Whitepaper FINAL 04-27-12 .pdf

Understanding ISO 17025 for Laser Power and Energy Measurement Whitepaper FINAL 04-27-12 .pdf

…standard; production
units are calibrated to working standards, working
standards are calibrated to golden standards, and
golden standards are calibrated to national standards.
While every major supplier engages in a traceable
calibration process, there are significant…

PowerMax-Pro USB/RS Sensors

PowerMax-Pro USB/RS Sensors

…2.0 (1.0 mm - up to 3% error) Calibration Uncertainty (%) (k=2) ±2 ±2 ±2 ±2 ±2 ±2 Power Linearity (%) ±5 ±5 ±5 ±5 ±5 ±5 Spectral Compensation Accuracy (%) ±3 ±3 ±3 ±3 ±3 ±3 Spatial Uniformity (%) ±5 ±5 ±5 ±5 ±5 ±5 (center 75% of aperture; 2.5 mm beam) Calibration Wavelength (nm) 810 810 810 810…

EnergyMax-USB/RS Sensors

EnergyMax-USB/RS Sensors

…OEM embedded applications
* Low Cost of Ownership
* Lower initial cost compared to traditional meter + sensor systems
* Lower calibration cost (no separate meter to calibrate)
* Simple integration lowers implementation costs
* Fast 14-bit A/D converter supports measurement accuracy similar to that…

Production Automation Options for META

Production Automation Options for META

…greatly increases throughput productivity. 4’ x 8’ Pallet option allows precise cuts over a large area, up to 4 ’ by 8 ‘. The 4’ x 8’ pallet is calibrated and aligned to match perfectly between cutting sections, ramping power at the meeting point to maintain constant energy delivery and a blemish…

ISO 17025 Accreditation

ISO 17025 Accreditation

…accredited calibrations has itself received ISO 17025 accredited calibrations
* has a traceable path of calibration to independently maintained national or international standards
* provides both as received and outgoing testing data to customers in an approved format
* ensures the calibration

Prometheus

Prometheus

--> Prometheus Family of ultra-narrow linewidth (~1 kHz) frequency-tunable CW lasers with both 532 nm and 1064 nm wavelengths in a single package. Contact Us About This Product Close PRICE HERE Ultra-Narrow Linewidth CW DPSS Green Laser Prometheus laser, as the whole Mephisto family, is based on a…

THz-Raman® Spectroscopy Microscope Module

THz-Raman® Spectroscopy Microscope Module

…spectra from 5 cm -1 to >3000 cm -1 (150 GHz to 90 THz)
* Simultaneous Stokes and anti-Stokes signals improve SNR while providing inherent calibration reference
* Available as add-on to an existing microscope or Raman system, or as a complete custom configured system
* Simple optical in/out…

THz-Raman® Spectroscopy Benchtop Module

THz-Raman® Spectroscopy Benchtop Module

…spectra from 5 cm -1 to >3000 cm -1 (150 GHz to 90 THz)
* Simultaneous Stokes and anti-Stokes signals improve SNR while providing inherent calibration reference
* Can be added on to an existing Raman system or spectrometer, or incorporated into a complete turnkey system
* Available at 532 nm,…

TR-PROBE for Raman System Measurements

TR-PROBE for Raman System Measurements

…THz-Raman spectra from 5cm -1 to >3000cm -1 (150GHz to 90THz)
* Simultaneous Stokes and anti-Stokes signals improve SNR while providing inherent calibration reference
* Can be added on to an existing Raman system or spectrometer, or as a complete custom configured system
* Available at 532nm, 785nm,…

kW PowerMax Pro Sensor

kW PowerMax Pro Sensor

…Beam Size (mm) 10 at 1 kW avg. power 20 at 3 kW avg. power Calibration Uncertainty (&%) (k=2) ±2.5 Power Linearity (%) ±3 Back Reflection (%) <1 when used with QBH Adapter 0 Wavelength Range (%) Fixed calibration point ±50 Calibration Wavelength² 810 nm, 1070 nm, 10.6 μm Cooling Method³ Water…

WaveMaster Wavelength Meter

WaveMaster Wavelength Meter

…easy-to-read 3 Hz rate. In the pulse mode, the display is updated at 3 Hz, and maintained for 5 seconds after a pulse for reading single events. Calibration is maintained by sophisticated algorithms that monitor the WaveMaster’s response. Periodically, and upon indication from the algorithms, the…