Search Results

1 - 12 of 17 Products for 'Calibration Certificate' Page 1 of 2 |

Calibration Certificate

COHERENT LMC 2016-2017 Catalog .pdf

COHERENT LMC 2016-2017 Catalog .pdf

…sensor
(available on both the calibration certificate and the
calibration sticker attached to the sensor cable), and
the typical laser pulse energy.
POWER
& ENERGY
Custom
& OEM
BEAM
DIAGNOSTICS
CALIBRATION
& SERVICE
Power

EnergyMax-USB/RS User Manual

EnergyMax-USB/RS User Manual

…Optical
Calibration
Method
EnergyMax NIST
Traceable Optical
Calibration
Coherent provides a NIST (U.S. National Institute of Standards and
Technology) traceable calibration certificate with every sensor that
is shipped.
The calibration factor of an…

PowerMax-USB-RS-Sensors-Product-Guide.pdf

PowerMax-USB-RS-Sensors-Product-Guide.pdf

…the
sensor, and additional error can be present if the ambient
measurement environment differs from the calibration
wavelength listed on the calibration certificate.
In practice, wavelengths shorter than 1000 nm have
insignificant effects due to temperature.
See the…

Global ISO 17025.2017 ANAB Certificate  Scope Exp.Mar2020.pdf

Global ISO 17025.2017 ANAB Certificate Scope Exp.Mar2020.pdf


CALIBRATION
Valid to: March 15, 2020 Certificate Number: AC-1630
Photometry and Radiometry
Parameter / Equipment Range
Expanded Uncertainty of
Measurement (+/-)
Reference Standard,
Method and/or
Equipment
Electrical Calibration of Laser…

Global ISO 17025 ANAB Certificate Exp Mar2020 09-17-20 18.pdf

Global ISO 17025 ANAB Certificate Exp Mar2020 09-17-20 18.pdf

…while demonstrating technical competence in the field of CALIBRATION Refer to the accompanying Scope of Accreditation for information regarding the types of calibrations to which this accreditation applies. AC-1630 Certificate Number Certificate Valid: 09/14/2018-03/15/2020 Version No. 009 Issued:…

Global ISO 17025-2017 ANAB Certificate Scope Exp May2022-V012.pdf

Global ISO 17025-2017 ANAB Certificate Scope Exp May2022-V012.pdf


CALIBRATION
Valid to: May 15, 2022 Certificate Number: AC-1630
Photometry and Radiometry
Parameter / Equipment Range
Expanded Uncertainty of
Measurement (+/-)
Reference Standard,
Method and/or
Equipment
Electrical Calibration of Laser…

Understanding ISO 17025 for Laser Power and Energy Measurement Whitepaper FINAL 04-27-12 .pdf

Understanding ISO 17025 for Laser Power and Energy Measurement Whitepaper FINAL 04-27-12 .pdf

…procedures used, and the calibration and
measurement capabilities. The scope refers to a
certificate of accreditation.
The scope table for a calibration laboratory contains the
following elements:
Measuring instrument
Specific calibrations performed
Specific…

Understanding-ISO-17025-for-Laser-Power-and-Energy-Measurement FORMFIRST.pdf

Understanding-ISO-17025-for-Laser-Power-and-Energy-Measurement FORMFIRST.pdf

…procedures used, and the calibration and
measurement capabilities. The scope refers to a
certificate of accreditation.
The scope table for a calibration laboratory contains the
following elements:
Measuring instrument
Specific calibrations performed
Specific…

COHR OP-2 LM-2 OpticalSensors DS 0719 1.pdf

COHR OP-2 LM-2 OpticalSensors DS 0719 1.pdf

…sensor
in place of the light shield to provide from 1100:1 to 950:1 attenuation. Each attenuator is
calibrated for 1000:1 ±5% at 635 nm and is supplied with a calibration certificate. The useful
spectral range is 400 to 1800 nm. The clear input aperture is 0.312" (7.9 mm) in diameter.…

COHR OP-2 LM-2 OpticalSensors DS 1119 2.pdf

COHR OP-2 LM-2 OpticalSensors DS 1119 2.pdf

…sensor
in place of the light shield to provide from 1100:1 to 950:1 attenuation. Each attenuator is
calibrated for 1000:1 ±5% at 635 nm and is supplied with a calibration certificate. The useful
spectral range is 400 to 1800 nm. The clear input aperture is 0.312" (7.9 mm) in diameter.…

LabMax-Pro SSIM User Manual

LabMax-Pro SSIM User Manual

…DC impedance)
Power jack (12 VDC - center positive)
Part Numbera 1268881
a. Meter supplied with AC power adapter, power cord, USB cable, trigger cable, software and driver CD, and certificate of calibration.
Table A-1. Specifications (Sheet 2 of 2)
Parameter Description

LabMax-Pro-Data-Sheet FORMFIRST.pdf

LabMax-Pro-Data-Sheet FORMFIRST.pdf

…300 ohm DC impedance)
Power jack (12VDC - center positive)
Part Number1 1268881
Laser Power and Energy Meter
LabMax-Pro SSIM
1 Meter supplied with AC power adapter, power cord, USB cable, BNC-to-SMB trigger cable, software and driver CD, and certificate of calibration.