Search Results

Refine
1 - 12 of 36 Products for 'Calibration Uncertainty' Page 1 of 3 |
Related Categories: Laser Pdf | Calibration Interval | Iso 9001

Calibration Uncertainty

Understanding-ISO-17025-for-Laser-Power-and-Energy-Measurement FORMFIRST.pdf

Understanding-ISO-17025-for-Laser-Power-and-Energy-Measurement FORMFIRST.pdf

…to specify calibration
capability is uncertainty. Calibration uncertainty defines
how far away readings from a given instrument should
be to the actual, true value of the parameter being
measured. This uncertainty takes into account the
combined uncertainties from all stages…

kW PowerMax Pro Sensor

kW PowerMax Pro Sensor

…Beam Size (mm) 10 at 1 kW avg. power 20 at 3 kW avg. power Calibration Uncertainty (&%) (k=2) ±2.5 Power Linearity (%) ±3 Back Reflection (%) <1 when used with QBH Adapter 0 Wavelength Range (%) Fixed calibration point ±50 Calibration Wavelength² 810 nm, 1070 nm, 10.6 μm Cooling Method³ Water…

PowerMax-Pro USB/RS Sensors

PowerMax-Pro USB/RS Sensors

…2.0 (1.0 mm - up to 3% error) Calibration Uncertainty (%) (k=2) ±2 ±2 ±2 ±2 ±2 ±2 Power Linearity (%) ±5 ±5 ±5 ±5 ±5 ±5 Spectral Compensation Accuracy (%) ±3 ±3 ±3 ±3 ±3 ±3 Spatial Uniformity (%) ±5 ±5 ±5 ±5 ±5 ±5 (center 75% of aperture; 2.5 mm beam) Calibration Wavelength (nm) 810 810 810 810…

ISO 17025 Accreditation

ISO 17025 Accreditation

…accredited calibrations has itself received ISO 17025 accredited calibrations
* has a traceable path of calibration to independently maintained national or international standards
* provides both as received and outgoing testing data to customers in an approved format
* ensures the calibration

EnergyMax-USB/RS Sensors

EnergyMax-USB/RS Sensors

…OEM embedded applications
* Low Cost of Ownership
* Lower initial cost compared to traditional meter + sensor systems
* Lower calibration cost (no separate meter to calibrate)
* Simple integration lowers implementation costs
* Fast 14-bit A/D converter supports measurement accuracy similar to that…

WaveMaster Wavelength Meter

WaveMaster Wavelength Meter

…easy-to-read 3 Hz rate. In the pulse mode, the display is updated at 3 Hz, and maintained for 5 seconds after a pulse for reading single events. Calibration is maintained by sophisticated algorithms that monitor the WaveMaster’s response. Periodically, and upon indication from the algorithms, the…

1000-1Attentuator

1000-1Attentuator

…in place of the light shield, and provides from 1100:1 to 950:1 attenuation. Each attenuator is calibrated for 1000:1 ±5% at 647 nm in our laboratory and supplied with a certificate of calibration. The useful spectral range of the attenuator is 400-1800 nm. The attenuator can be used with power…

J-Power Pro Energy Sensor DB-25-to-BNC Adapter

J-Power Pro Energy Sensor DB-25-to-BNC Adapter

…of the output (as referenced from baseline voltage) can then be measured using an oscilloscope or another analog-to-digital input device. The calibrated peak voltage represents the integrated energy of the laser pulse. Name J-Power Pro sensor Adapter Description DB-25 to BNC Sensor Adapter Part…

Laser Check

Laser Check

…Features:
* Hand-held laser power meter
* Integrated sensor
* Auto-ranging with peak sample-and-hold
* Power measurement from 10 µW-10 mW
* ±8% calibrated accuracy from 400-1064 nm
* RoHS Compliant Contact Us About This Product PRICE HERE Close More Information LaserCheck is supplied ready to use,…

Understanding ISO 17025 for Laser Power and Energy Measurement Whitepaper FINAL 04-27-12 .pdf

Understanding ISO 17025 for Laser Power and Energy Measurement Whitepaper FINAL 04-27-12 .pdf

…to specify calibration
capability is uncertainty. Calibration uncertainty defines
how far away readings from a given instrument should
be to the actual, true value of the parameter being
measured. This uncertainty takes into account the
combined uncertainties from all stages…

EnergyMax-USB/RS User Manual

EnergyMax-USB/RS User Manual

…Power (mW) 60
Max. Pulse Width (µs) 1
Max. Rep. Rate (pps) 10000
Sensor Silicon
Diffuser ND2
Calibration Wavelength (nm) 532
Calibration Uncertainty (%) ± 3
Linearity (%) ± 3
Cable Length (m)
3 (sensor cable)
1 (USB/RS cable)
Cable Type USB and…

COHERENT LMC 2016-2017 Catalog .pdf

COHERENT LMC 2016-2017 Catalog .pdf

…Max. Pulse Width (µs) 200
Detector Coating Black
Detector Diameter (mm) 95
Dimensions (mm) Ø 153 x 65
Calibration Uncertainty (%)(k=2) ±2
Calibration Wavelength (nm) 1064
Connector Type BNC
Cable Length (m) 1.5 (separate)
Part Number 0011-6100
Features…

Please Read Before Continuing

Risk factors: Except for the historical information contained here, many of the matters discussed in this Web site are forward-looking statements, based on expectations at the time they were made, that involve risks and uncertainties that could cause our results to differ materially from those expressed or implied by such statements. These risks are detailed in the “Factors That May Affect Future Results” section of our latest 10-K or 10-Q filing. Coherent assumes no obligation to update these forward-looking statements.


I have read the terms and conditions