Search Results

Refine
1 - 12 of 39 Products for 'Calibration Uncertainty' Page 1 of 4 |

Calibration Uncertainty

Understanding-ISO-17025-for-Laser-Power-and-Energy-Measurement FORMFIRST.pdf

Understanding-ISO-17025-for-Laser-Power-and-Energy-Measurement FORMFIRST.pdf

…to specify calibration
capability is uncertainty. Calibration uncertainty defines
how far away readings from a given instrument should
be to the actual, true value of the parameter being
measured. This uncertainty takes into account the
combined uncertainties from all stages…

kW PowerMax Pro Sensor

kW PowerMax Pro Sensor

…Beam Size (mm) 10 at 1 kW avg. power 20 at 3 kW avg. power Calibration Uncertainty (&%) (k=2) ±2.5 Power Linearity (%) ±3 Back Reflection (%) <1 when used with QBH Adapter 0 Wavelength Range (%) Fixed calibration point ±50 Calibration Wavelength² 810 nm, 1070 nm, 10.6 μm Cooling Method³ Water…

PowerMax-Pro USB/RS Sensors

PowerMax-Pro USB/RS Sensors

…Set by damage threshold Calibration Uncertainty (%) (k=2) ±2 ±2 ±2 ±2 ±2 ±2 ±2 Power Linearity (%) ±5 ±5 ±5 ±5 ±5 ±5 ±2 Spectral Compensation Accuracy (%) ±3 ±3 ±3 ±3 ±3 ±3 ±5 Spatial Uniformity (%) ±5 ±5 ±5 ±5 ±5 ±5 ±5 (center 75% of aperture; 2.5 mm beam) Calibration Wavelength (nm) 801 801 801…

Understanding ISO 17025 for Laser Power and Energy Measurement Whitepaper FINAL 04-27-12 .pdf

Understanding ISO 17025 for Laser Power and Energy Measurement Whitepaper FINAL 04-27-12 .pdf

…to specify calibration
capability is uncertainty. Calibration uncertainty defines
how far away readings from a given instrument should
be to the actual, true value of the parameter being
measured. This uncertainty takes into account the
combined uncertainties from all stages…

EnergyMax-USB/RS User Manual

EnergyMax-USB/RS User Manual

…Power (mW) 60
Max. Pulse Width (µs) 1
Max. Rep. Rate (pps) 10000
Sensor Silicon
Diffuser ND2
Calibration Wavelength (nm) 532
Calibration Uncertainty (%) ± 3
Linearity (%) ± 3
Cable Length (m)
3 (sensor cable)
1 (USB/RS cable)
Cable Type USB and…

COHERENT LMC 2016-2017 Catalog .pdf

COHERENT LMC 2016-2017 Catalog .pdf

…Max. Pulse Width (µs) 200
Detector Coating Black
Detector Diameter (mm) 95
Dimensions (mm) Ø 153 x 65
Calibration Uncertainty (%)(k=2) ±2
Calibration Wavelength (nm) 1064
Connector Type BNC
Cable Length (m) 1.5 (separate)
Part Number 0011-6100
Features…

EnergyMax-USB-RS-Sensors-Guide FORMFIRST.pdf

EnergyMax-USB-RS-Sensors-Guide FORMFIRST.pdf

7
· Toll Free: (800) 343-4912 · Tel: (408) 764-4042 · Fax: (503) 454-5727
Overall measurement accuracy is a combination of calibration uncertainty
(found in the sensor specification tables) and the wavelength compensation
accuracy (found in the"Wavelength Compensation Accuracy"…

COHR Fan-CooledThermopileSensors DB25 DS 0719 1.pdf

COHR Fan-CooledThermopileSensors DB25 DS 0719 1.pdf

…10 ns
Response Time (sec.) 2 5 2 5
Detector Coating Broadband
Active Area Diameter (mm) 19 50 19 50
Calibration Uncertainty (%) (k=2) ±1
Calibration Wavelength (nm) 514
Cooling Method Fan-cooled
Cable Type PM DB-25
Cable Length (m) 2
Part Number 1098480…

COHR Air-CooledThermopileSensors DB25 DS 0819 2.pdf

COHR Air-CooledThermopileSensors DB25 DS 0819 2.pdf

…nm, 10 ns
Response Time (sec.) 2 5 5
Detector Coating Broadband
Active Area Diameter (mm) 19 50 50
Calibration Uncertainty (%) (k=2) ±1
Calibration Wavelength (nm) 514
Cooling Method Air-cooled
Cable Type PM DB-25
Cable Length (m) 2
Part Number 1098483…

COHR HighPowerWater-CooledThermopileSensors DB25 DS 0719 1.pdf

COHR HighPowerWater-CooledThermopileSensors DB25 DS 0719 1.pdf

…Density (mJ/cm2) 600
Response Time (sec.) 30
Detector Coating Broadband
Active Area Diameter (mm) 50
Calibration Uncertainty (%) (k=2) ±3
Calibration Wavelength (nm) 1070
Cooling Method Water
Cable Type PM DB-25
Cable Length (m) 2
Part Number 10983923…

COHR Fan-CooledThermopileSensors DB25 DS 0919 2.pdf

COHR Fan-CooledThermopileSensors DB25 DS 0919 2.pdf

…10 ns
Response Time (sec.) 2 5 2 5
Detector Coating Broadband
Active Area Diameter (mm) 19 50 19 50
Calibration Uncertainty (%) (k=2) ±1
Calibration Wavelength (nm) 514
Cooling Method Fan-cooled
Cable Type PM DB-25
Cable Length (m) 2
Part Number 1098480…

COHR Fan-CooledThermopileSensors DB25 DS 1119 3.pdf

COHR Fan-CooledThermopileSensors DB25 DS 1119 3.pdf

…10 ns
Response Time (sec.) 2 5 2 5
Detector Coating Broadband
Active Area Diameter (mm) 19 50 19 50
Calibration Uncertainty (%) (k=2) ±1
Calibration Wavelength (nm) 514
Cooling Method Fan-cooled
Cable Type PM DB-25
Cable Length (m) 2
Part Number 1098480…