Ccd Detector

Polymorph-Characterization-of-Active-Pharmaceutical-Ingredients-Using-Low-Frequency-Raman-Spectroscopy-Web.pdf

Polymorph-Characterization-of-Active-Pharmaceutical-Ingredients-Using-Low-Frequency-Raman-Spectroscopy-Web.pdf

…Instruments, Acton, MA) with a 1200 grooves/mm
holographic visible grating and a Pixis 2048 3 2048 backilluminated charge-coupled device (CCD) camera (Princeton Instruments, Trenton, NJ) thermoelectrically cooled to
À55 8 C. The single-stage spectrograph was interfaced via
a…

SurfaceCatalystStructure AstrellaProfXiong2D Case Study FINAL.pdf

SurfaceCatalystStructure AstrellaProfXiong2D Case Study FINAL.pdf

…Research Group8,9. The Xiong group's spectrometer also includes a
low noise CCD camera to simultaneously record dispersed SFG spectra at 1024 wavelength
channels centered around 690 nm. Prior to reaching the detector array, the SFG signal is
boosted by a local oscillator and combined…

Quotation KML QGYYMMDD G  Institute Contact

Quotation KML QGYYMMDD G Institute Contact

…subsequently dispersed onto a
CCD to allow for the flux per
harmonic order to be determined.
In this set of measurements, the CCD detector was cross-calibrated at KMLabs with the NISTcalibrated diode, with flux measurements determined using the CCD. Different spectral regions
are…

Laser Focus World - September 2015

Laser Focus World - September 2015

…× 15 × 11.5 mm and contains a 5 Mpixel detector with a 2.2 µm pixel size (see Fig. 5).
"Cinogy's beam profilers are all based on 2D detectors associated with software that provides uniquely fast measurement,"
he adds. "CMOS, CCD, or SWIR detectors types are used for
the beam profilers…

COHR Femtosecond Amplifier Provides Turnkey Access to Extreme Operating Regimes WP.pdf

COHR Femtosecond Amplifier Provides Turnkey Access to Extreme Operating Regimes WP.pdf

…the main components used in this successful HHG demonstration. The HHG was
analyzed using an EUV imaging spectrometer followed by a EUV CCD array detector. When argon
is used as the fill gas, the output consists of several harmonics centered in the "near-EUV" at 35
nm. When helium is…

Chameleon Reliability Antarctia Final WP.pdf

Chameleon Reliability Antarctia Final WP.pdf

…air of the
laser pulses is ~10 km, resulting in a signal level
sufficient for spectral analysis with a dispersive grating
and a CCD detector. However, this technique requires
a very stable coupling between the laser and
measurement cavity length and superb pointing stability…

Microsoft Word - Understand Different Laser Beam  Rev 1 Final.doc

Microsoft Word - Understand Different Laser Beam Rev 1 Final.doc

…Wavelength
The wavelength being measured largely determines the type of
detector device needed. For the wavelength range from 190 nm to
1100 nm, CCD and CMOS cameras or Si-sensor based knife-edge
detectors should be the choice technology. For the near infrared,
from 800 nm…

untitled

untitled

…Inc.) with an entrance slit width of 50 lm
(SLIT-50) and a thermoelectrically cooled 1024 3 256
element charge-coupled device (CCD) detector (Andor
CC-001). The single-stage spectrograph was interfaced
via a 25 lm diameter 0.1 numerical aperture (NA) step
index (HJPSC25,…

MerMAIDs: a family of metagenomically discovered marine anion-conducting and intensely desensitizing channelrhodopsins

MerMAIDs: a family of metagenomically discovered marine anion-conducting and intensely desensitizing channelrhodopsins

…configuration (180°) using a confocal LabRamHR
spectrometer (Horiba, Villeneuve, France) equipped with a liquid nitrogen-cooled
CCD detector. Data was collected with the LabSpec Spectroscopy Suite software
(Horiba). The spectral resolution was approximately 2 cm-1. Typical total…

LIT Lasers-LED NO3-Cost-Issues 1114.pdf

LIT Lasers-LED NO3-Cost-Issues 1114.pdf

…excitation, but may need a photomultiplier tube or a CCD array when used with a LED source. For instances where a laser-based instrument uses a room- temperature CCD array, the LED version of the same instrument might need an actively-cooled CCD array. Unit-to-Unit Variability - Supply Chain…

Microsoft Word - 5694-20 submitted.doc

Microsoft Word - 5694-20 submitted.doc

…The Bragg-matched incident angle is 450 at 632nm. A commercially
available, scientific grade, CCD camera was used with a local computer for all data recording. It had a 1024x1024
detector array and 10-bit digitization. The camera provided low noise imaging, fast response time and fine…