Search Results

Refine

Result Type

1 - 12 of 12 Products for 'Ccu' Page 1 of 1 |
  • 1

Ccu

COHR HighLightFL Compact SingleMode DS 0818.pdf

COHR HighLightFL Compact SingleMode DS 0818.pdf

…V (A) 3.7; CCU: 4.2 4.9; CCU: 5.4 6.2; CCU: 6.7 8.7; CCU: 9.2 11.4; CCU: 1.9 12.5; CCU: 13
Fuses Type NH (A) 16 32
COOLING
Recommended Cooling Capacity
* (kW) 2.4 3.2 4 5.6 7.3 8.1
Flow Rate (l/h) 1000; CCU Laser: 850; Optic: 150
Temperature (°C) 25; CCU Laser: 25; Optics:…

COHR HighLightFL Compact MultiMode DS 0818.pdf

COHR HighLightFL Compact MultiMode DS 0818.pdf

…V (A) 3.7; CCU: 4.2 4,9; CCU: 5.4 6.2; CCU: 6.7 8.7; CCU: 9.2 11.4; CCU: 11.9 12.5; CCU: 13
Fuses Type NH (A) 16 32
COOLING
Recommended Cooling Capacity
* (kW) 2.4 3.2 4 5.6 7.3 8.1
Flow Rate (l/h) 1000; CCU Laser: 850; Optic: 150
Temperature (°C) 25; CCU Laser: 25; Optic:…

COHR HighLightFL Standard FFC DS 0818.pdf

COHR HighLightFL Standard FFC DS 0818.pdf

…(A) 12.5; CCU: 13 17; CCU: 17.5 22; CCU: 22.5 25.1; CCU: 25.6
Fuses Type NH (A) 25 40 50
COOLING
Recommended Cooling Capacity
* (kW) 8.1 10.9 14.2 16.2
Flow Rate
*
* (l/h) 1600 ; CCU Laser: 950;
Optic: 400
2700 ; CCU Laser: 2150;
Optic: 400
2700 ; CCU Laser:…

COHR HighLightFL Standard FFS DS 0818.pdf

COHR HighLightFL Standard FFS DS 0818.pdf

…3.2;
CCU: 3.7
5;
CCU: 5.5
6.3;
CCU: 6.8
9.4;
CCU: 9.9
11.9;
CCU: 12.4
12.5;
CCU: 13
Fuses Type NH (A) 16 25
COOLING
Recommended Cooling Capacity
* (kW) 2.4 3.2 4 6.1 7.7 8.1
Flow Rate 2 fibers
*
* (l/h) 2200 ; CCU: Laser: 950;…

COHR HighLightFL Standard FFC DS 0619web.pdf

COHR HighLightFL Standard FFC DS 0619web.pdf

…(A) 12.5; CCU: 13 17; CCU: 17.5 22; CCU: 22.5 25.1; CCU: 25.6
Fuses Type NH (A) 25 40 50
COOLING
Recommended Cooling Capacity
* (kW) 8.1 10.9 14.2 16.2
Flow Rate
*
* (l/h) 1600 ; CCU Laser: 950;
Optic: 400
2700 ; CCU Laser: 2150;
Optic: 400
2700 ; CCU Laser:…

COHR HighLightFL Standard FFS DS 0619web.pdf

COHR HighLightFL Standard FFS DS 0619web.pdf

…33.3; CCU: 33.8 44.3; CCU: 44.8 45; CCU: 45.5
Fuses Type NH (A) 50
COOLING
Recommended Cooling Capacity
* (kW) 21.5 28.5 29
Flow Rate 2 fibers
*
* (l/h) 4500 ; CCU: Laser: 2900;
Optic: 1150
5300 ; CCU: Laser: 3600 ; Optic: 1150
Flow Rate 4 fibers
*
* (l/h) 4800 ; CCU:

COHR HighLightFL Compact MultiMode DS 0619web.pdf

COHR HighLightFL Compact MultiMode DS 0619web.pdf

…Consumption at 400 V (A) 6.2; CCU: 6.7 8.7; CCU: 9.2 11.4; CCU: 11.9 12.5; CCU: 13
Fuses Type NH (A) 16 32
COOLING
Recommended Cooling Capacity
* (kW) 4 5.6 7.3 8.1
Flow Rate (l/h) 1000; CCU Laser: 850; Optic: 150
Temperature (°C) 25; CCU Laser: 25; Optic: 34
Temperature…

COHR HighLightFL Compact SingleMode DS 0619web.pdf

COHR HighLightFL Compact SingleMode DS 0619web.pdf

…Consumption at 400 V (A) 6.2; CCU: 6.7 8.7; CCU: 9.2 11.4; CCU: 1.9 12.5; CCU: 13
Fuses Type NH (A) 16 32
COOLING
Recommended Cooling Capacity
* (kW) 4 5.6 7.3 8.1
Flow Rate (l/h) 1000; CCU Laser: 850; Optic: 150
Temperature (°C) 25; CCU Laser: 25; Optics: 34
Temperature…

COHR HighLight DL-HP DS 0918.pdf

COHR HighLight DL-HP DS 0918.pdf

…Temperature (°C) 22; CCU Laser: 22; Optic: 35
Temperature Tolerance Range (°C) ± 1
Flow rate (l/min) 45; CCU
*
*
Laser:
20; Optics: 25
47; CCU
*
*
Laser:
22; Optics: 25
55; CCU
*
*
Laser:
25; Optics: 30
60; CCU
*
*
Laser:
30; Optics: 30
65; CCU
*
*
Laser:

COHR HighLight DL-HQ DS 0918.pdf

COHR HighLight DL-HQ DS 0918.pdf

…Temperature (°C) 22; CCU
*
*
Laser: 22; Optic: 35
Temperature Tolerance Range (°C) ± 1
Flow Rate (l/min) 28; CCU
*
*
Laser: 20; Optics: 8 55; CCU
*
*
Laser: 30; Optics: 20 55; CCU
*
*
Laser: 35; Optics: 35
Max. Pressure (bar) <6
Pressure Drop (bar) <2; CCU
*
*
Laser: <2.5; Optic:…

COHR HighLightDL HPS DS 0819.pdf

COHR HighLightDL HPS DS 0819.pdf

…~1050 x ~1760
Laser Weight; w/o cooling water and CCU
*
*
*
*
(kg) 380
ENVIRONMENTAL CONDITIONS
Ambient Temperature (°C) +10 to +40
Humidity Non-condensing environment
Dew Point Temperature (°C) 19 w/o CCU
*
*
*
* / 32 with CCU
*
*
*
*

Storage (°C) 5 to 50
CUSTOMER INTERFACE…

COHR HighLightFL1000P DS 0617.pdf

COHR HighLightFL1000P DS 0617.pdf

…900 x 600
Laser Weight (kg) <200
ENVIRONMENTAL CONDITIONS
Ambient Temperature (°C) 5 to 40
Humidity 10% to 90% non-condensing; CCU or dry air kit
CUSTOMER INTERFACE
Digital Signals (V DC) 24
Power Control (V DC) 0 to 10
Trigger Control (V) Gate 24,15, or 5;…