1 - 12 of 78 Products for 'Chiller' Page 1 of 7 |

Chiller

00 Laser Cooling.book

00 Laser Cooling.book

…match the operating requirements of
ion lasers. Details are given in Appendix A: Coherent Cooling
Options.
Closed-Loop
Chiller
Chillers have many of the same advantages of heat exchangers
insofar as a fixed volume of water is recirculated through the laser.
Unlike…

Preinstallation Manual Astrella Ultrafast Amplifier Laser System

Preinstallation Manual Astrella Ultrafast Amplifier Laser System

…3-4
Utility Requirements.................................................................................................. 3-4
Chiller Fluid Requirements........................................................................................ 3-5
Facility Water Requirement…

Verdi preinstall.book

Verdi preinstall.book

…fault protection.
4. Proceed to the paragraph titled, "Installing the Chiller".
Installing the
Chiller
Install and setup the chiller in accordance with the user's manual
furnished with the chiller
Final Installation
and Initial
Turn-On
Procedures

HyperRapid NX/NXT - Industrial Picosecond Laser

HyperRapid NX/NXT - Industrial Picosecond Laser

…head is a self-contained system where all optical elements, control electronics, and thermo-mechanical management are integrated. It complies with state-of-the-art safety regulation and it is complemented by a selection of off-the-shelf chillers and power supplies to offer the greatest flexibility.

00 E-1000 PreInst.book

00 E-1000 PreInst.book

…come after the laser system.
Chiller Electrical
Supply
A large industrial chiller normally requires a 230 or 480 VAC,
3-phase electrical supply with its own circuit breaker or fuse protection and an electrical disconnect. Refer to the chiller manufacturer's
installation…

00 E-400 E-1000 Series Preinstall.book

00 E-400 E-1000 Series Preinstall.book

…come after the laser system.
Chiller Electrical
Supply
A large industrial chiller normally requires a 230 or 480 VAC,
3-phase electrical supply with its own circuit breaker or fuse protection and an electrical disconnect. Refer to the chiller manufacturer's
installation…

Paladin Advanced Preinstallation.book

Paladin Advanced Preinstallation.book

…from the chiller. Figure 3-16 shows the connections on the back of
the laser head and chiller. Activate the chiller query with the service
command "CH=1" (see Table 6-3 on page 6-5)
Active Chiller Control The Paladin chiller is preset for "active chiller". "Active chiller"

Quick Setup.fm

Quick Setup.fm


1. Hook the laser head to the chiller using the provided hardware, see Figures 1 - 3.
Note, for increased visibility the umbilical has been removed from the laser head in Figure 3.
2. Fill the chiller reservoir with distilled water, start the chiller (see Figure 4), and inspect all…

Laser Marking Workstations

Laser Marking Workstations

…module (oscillating table configuration only)
* Digital readout, motorized or programmable upgrade of Z-Axis
* Refrigerated recirculating water chiller for all LME-RM versions (laser dependent)
* Automated Pick ‘N Place parts handling
* Custom Motion Control ability
* Fume extractor, available for…

DIAMOND J-3 Series OEM Lasers Preinstallation Manual, Rev. AB

DIAMOND J-3 Series OEM Lasers Preinstallation Manual, Rev. AB

…come after the laser system.
Chiller Electrical
Supply
A large industrial chiller normally requires a 230 or 480 VAC,
3-phase electrical supply with its own circuit breaker or fuse
protection and an electrical disconnect. Refer to the chiller
manufacturer's installation…

2016-Ultrafast-Laser-Systems-Catalog.pdf

2016-Ultrafast-Laser-Systems-Catalog.pdf

…Utility Requirements
Operating Voltage (VAC) 90 to 250 (auto ranging)
Maximum Operating Current (A)
Power Supply <8 at 90 VAC
Chiller <14 at 90 VAC
MRU <2 at 90 VAC
System Power Consumption (W) 2300
Line Frequency (Hz) 47 to 63
Communications/Control…

Preinstallation Manual Paladin Advanced Mode Locked UV Laser System

Preinstallation Manual Paladin Advanced Mode Locked UV Laser System

Description and Specifications
2 - 13
Figure 2-4. Termotek Chiller P307-16273 (for 16W-35W Systems) (Continued)
440

Please Read Before Continuing

Risk factors: Except for the historical information contained here, many of the matters discussed in this Web site are forward-looking statements, based on expectations at the time they were made, that involve risks and uncertainties that could cause our results to differ materially from those expressed or implied by such statements. These risks are detailed in the “Factors That May Affect Future Results” section of our latest 10-K or 10-Q filing. Coherent assumes no obligation to update these forward-looking statements.