Search Results

Refine

Result Type

1 - 12 of 24 Products for 'Chiller Coolant' Page 1 of 2 |
Related Categories: Termotek | 460 Nalco | P307 | Fin Lase | Paladin Manual

Chiller Coolant

Preinstallation Manual Paladin Advanced Mode Locked UV Laser System

Preinstallation Manual Paladin Advanced Mode Locked UV Laser System

…When the coolant level has reached the "Max." line, connect
the chiller to a power source. The chiller moves the coolant
through the laser head and the coolant level will fall. Add more
coolant to reach the "Max." line.
· Paladin 8W/10W: if the amount of coolant is not…

Diamond J-5 Series OEM Lasers Preinstallation Manual, Rev. AC

…at all times.
A closed-loop cooling system (chiller) should be used to obtain
consistent and stable laser performance. The chiller must be able to
remove up to 9.5 kW of heat. The coolant composition for the
closed-loop chiller is described in the following section.
A…

00 E-250 Pre.book

00 E-250 Pre.book

…they may be cooled by a separate chiller.
Coolant Temperature At the laser head, the inlet temperature of the cooling fluid should
always be above the dew point to prevent condensation from developing inside the laser head or RF power module.
Coolant Filtering To prevent accumulation…

DIAMOND J-3 Series OEM Lasers Preinstallation Manual, Rev. AB

DIAMOND J-3 Series OEM Lasers Preinstallation Manual, Rev. AB

…they may be cooled by a separate chiller.
Coolant Temperature At the laser head, the inlet temperature of the cooling fluid should
always be above the dew point to prevent condensation from developing inside the laser head or RF power module.
Coolant Filtering To prevent accumulation…

DIAMOND J-5 Series OEM Lasers Preinstallation Manual Rev AA

DIAMOND J-5 Series OEM Lasers Preinstallation Manual Rev AA

…they may be cooled by a separate chiller.
Coolant Temperature At the laser head, the inlet temperature of the cooling fluid should
always be above the dew point to prevent condensation from developing inside the laser head or RF power module.
Coolant Filtering To prevent accumulation…

Diamond J-2 Series OEM Lasers Preinstallation Manual, Rev. AB

…may be cooled by a separate chiller.
Coolant Temperature At the laser head, the inlet temperature of the cooling fluid should
always be above the dew point to prevent condensation from
developing inside the laser head or RF power module.
Coolant Filtering To prevent accumulation…

Diamond J-3 Series OEM Lasers Preinstallation Manual, Rev. AC

Diamond J-3 Series OEM Lasers Preinstallation Manual, Rev. AC

…they may be cooled by a separate chiller.
Coolant Temperature At the laser head, the inlet temperature of the cooling fluid should
always be above the dew point to prevent condensation from developing inside the laser head or RF power module.
Coolant Filtering To prevent accumulation…

Diamond J-3-5 Series OEM Lasers Preinstallation Manual, Rev. AA

Diamond J-3-5 Series OEM Lasers Preinstallation Manual, Rev. AA

…they may be cooled by a separate chiller.
Coolant Temperature At the laser head, the inlet temperature of the cooling fluid should
always be above the dew point to prevent condensation from developing inside the laser head or RF power module.
Coolant Filtering To prevent accumulation…

DIAMOND J-5V Series OEM Lasers Preinstallation Manual, Rev. AA

DIAMOND J-5V Series OEM Lasers Preinstallation Manual, Rev. AA

…they may be cooled by a separate chiller.
Coolant Temperature At the laser head, the inlet temperature of the cooling fluid should
always be above the dew point to prevent condensation from developing inside the laser head or RF power module.
Coolant Filtering To prevent accumulation…

Paladin Advanced Preinstallation.book

Paladin Advanced Preinstallation.book

…into the funnel.
5. When the coolant level has reached the Max. line, connect the
chiller to a power source. The chiller moves the coolant
through the laser head. The coolant level will fall. Add more
coolant to reach the Max, line.If coolant level is not sufficient,
two…

00 E-400 E-1000 Series Preinstall.book

00 E-400 E-1000 Series Preinstall.book

…parallel circuits at the laser system. Refer to
Figure 2.
Figure 2. Coolant Flow to Laser System
OK Chiller
SUPPLY
RETURN
SUPPLY
SUPPLY
RETURN
RETURN
Chiller
Chiller
Laser Head
RF Power Module
Laser Head
Laser Head
RF…

00 E-1000 PreInst.book

00 E-1000 PreInst.book


Coolant Filtering To prevent accumulation of debris in the cooling system, the coolant
should be filtered at the inlet to the laser system. Coherent recommends the use of a particle filter that traps particles larger than
30 µm in diameter, unless specified by the chiller manufacturer…