Refine
1 - 12 of 24 Products for 'Cleaning Chiller' Page 1 of 2 |

Cleaning Chiller

Picosecond laser

Picosecond laser

1 Pre-Installation Guide May 2016
Maintenance l
Exchanging cooling liquid, cleaning or exchanging filter
(inside the chiller)
l
Exchanging desiccant cartridges inside the laser head
l
The laser system offers software supported maintenance to
sustain the laser…

Preinstallation Manual Astrella Ultrafast Amplifier Laser System

Preinstallation Manual Astrella Ultrafast Amplifier Laser System

Area is clean and large enough to uncrate the laser, power
supplies and chiller.
"Receiving and Inspection" on page 3-1
Utility
Requirements

Seed Laser

Pump Laser

Synchronization & Delay Generator (SDG Elite)

Laptop Computer

Chiller, Pump Laser

RAPID FX

RAPID FX

…suited for applications that benefit from even shorter pulses: Femtosecond pulses allow for true nonthermal material processing, allowing for very clean processing results. The RAPID FX is designed for industrial micromachining and offers femtosecond machining capability at an unprecedented price…

Astrella Ultrafast Amplifier Laser System Preinstallation Manual

Astrella Ultrafast Amplifier Laser System Preinstallation Manual

Area is clean and large enough to uncrate the laser, power
supplies and chiller.
"Receiving and Inspection" on page 3-1
Utility
Requirements

Seed Laser

Pump Laser

Synchronization & Delay Generator (SDG Elite)

Laptop Computer

Chiller, Pump Laser

00 Legend Elite Preinstallation.book

00 Legend Elite Preinstallation.book

…and
Inspect

Area is clean and large enough to uncrate the laser, power
supplies and chiller.
"Unpacking and
Inspection" on
page 3-1
Utility
Requirements

Seed Laser

Chiller, Seed Laser

Pump Laser

Chiller, Pump Laser

Signal Delay Generator…

Diamond J-3-5 Series OEM Lasers Preinstallation Manual, Rev. AA

Diamond J-3-5 Series OEM Lasers Preinstallation Manual, Rev. AA

…in this table.
(4) Measured from system inlet to outlet ports and does not include the pressure drop from chiller fittings or the
supply and return hose.
(5) Clean dry air or nitrogen are acceptable as purge gases. Coherent can recommend suitable commercial gas
filter/dryers.…

Vitara Preinstall.book

Vitara Preinstall.book

…dimensions.
See "Utility and Environmental Requirements" on page 3-2.
Receive and
Inspect
[ ] Area is clean and large enough to uncrate the laser and chiller.
See "Receiving and
Inspection" on page 3-1
Utility
Requirements
[ ] Utility outlets (115V/20A,…

UCLD Catalog.book

UCLD Catalog.book

…laser head, power supply, and chiller layout; FAP
assembly replacement; performing output power calibration; limited troubleshooting techniques; desiccant
chamber(s) removal and replacement; Brewster window cleaning; head, power supply, and chiller swaps; RS-232
operation; modem…

Libra PreInstallation.book

Libra PreInstallation.book


See "Utility and Environmental Requirements" on page 3-2.
Receive and
Inspect

Area is clean and large enough to uncrate the laser, power
supplies and chiller.
See "Receiving and
Inspection" on page 3-1
Utility
Requirements

Utility outlets (115V/20A,…

00 LMT Pre.book

00 LMT Pre.book

chiller. Cut the tubing in half.
The included filter is installed in-line before the input to the LMC.
Also included are two ½" (12.7mm) chiller outlet fittings with ¾"
NPT threads.
Install the filter, then connect:
· Outlet of chiller to input of LMC
· Inlet of chiller

Paladin Advanced Preinstallation.book

Paladin Advanced Preinstallation.book

…surface.
[ ] Put the power supply on a stable surface.
[ ] Put the chiller on a stable surface.
[ ] Connect the chiller to the laser head.
[ ] Fill the chiller with NALCOTM.
[ ] Connect chiller to the power line.
[ ] Open the front panel of the master (and slave) power…

Preinstallation Manual Paladin Advanced Mode Locked UV Laser System

Preinstallation Manual Paladin Advanced Mode Locked UV Laser System

…secure the slave cable between slave power
supply and laser head (16/24/35 W System).
[ ] Connect serial cable between laser head and chiller.
[ ] Connect and secure slave power cable and slave control
cable between both slave power supplies (35 W).
[ ] Connect the power…

Please Read Before Continuing

Risk factors: Except for the historical information contained here, many of the matters discussed in this Web site are forward-looking statements, based on expectations at the time they were made, that involve risks and uncertainties that could cause our results to differ materially from those expressed or implied by such statements. These risks are detailed in the “Factors That May Affect Future Results” section of our latest 10-K or 10-Q filing. Coherent assumes no obligation to update these forward-looking statements.