Ask a Question
Coherent

Search Results

1 - 12 of 346 Products for 'Cooling Chiller' Page 1 of 29 |
Related Categories: Heat Exchanger | Water Circulator

Cooling Chiller

00 Laser Cooling.book

00 Laser Cooling.book

…heat exchanger systems, designed to match the operating requirements of ion lasers. Details are given in Appendix A: Coherent Cooling Options. Closed-Loop Chiller Chillers have many of the same advantages of heat exchangers insofar as a fixed volume of water is recirculated through the laser. Unlike…

00 Laser Cooling.book

00 Laser Cooling.book

…in the heat exchanger, which must itself be cooled by either liquid or air. · Closed-loop chiller: The cooling water circulates around a closed path that includes the laser and a chiller. The heat generated by the laser is removed in the chiller, typically a refrigeration unit which discharges…

LDP-100MQ

LDP-100MQ

…+/- 10% VAC, 1-phase, 50/60 Hz, 20A Average Consumption 2 kW, maximum with water / water cooler Cooling - Water City water, 16 1/m @ 15 C max. temp. Optional city-water cooled refrigerated chiller requires city water, 8 1/m @ 25 C max. temp Temperature Operating 18 - 33 C Humidity 10 - 90%,…

LDP-100TQ

LDP-100TQ

…+/- 10% VAC, 1-phase, 50/60 Hz, 20A Average Consumption 2 kW, maximum with water / water cooler Cooling - Water City water, 16 1/m @ 15 C max. temp. Optional city-water cooled refrigerated chiller requires city water, 8 1/m @ 25 C max. temp Temperature Operating 18 – 33 C Humidity 10 - 90%,…

LDP-100MQG

LDP-100MQG

…+/- 10% VAC, 1-phase, 50/60 Hz, 30A Average Consumption 2 kW, maximum with water / water cooler Cooling - Water City water, 16 l/m @ 15° C max. temp. Optional city-water cooled refrigerated chiller requires city water, 8 1/m @ 25 C max. temp Temperature Operating 18 – 30° C Humidity 10 - 90%,…

LDP-100TQG-DP

LDP-100TQG-DP

…+/- 10% VAC, 1-phase, 50/60 Hz, 20A Average Consumption 2 kW, maximum with water / water cooler Cooling - Water City water, 16 1/m @ 15 C max. temp. Optional city-water cooled refrigerated chiller requires city water, 8 1/m @ 25 C max. temp Temperature Operating 18 – 30 C Humidity 10 - 90%,…

RAPID

RAPID

…depth control). The RAPID consists of a sealed, compact laser head and a power supply. It only requires an ordinary main connection. The internal cooling system makes it independent from environmental conditions. The included intuitive software controls all laser functions via internal industrial…

laser cutting and machining tool

laser cutting and machining tool

…module (oscillating table configuration only)
* Digital readout, motorized or programmable upgrade of Z-Axis
* Refrigerated recirculating water chiller for all LME-RM versions (laser dependent)
* Automated Pick ‘N Place parts handling
* Custom Motion Control ability
* Fume extractor, available for…

00 Laser Cooling.book

00 Laser Cooling.book

…heat exchanger systems, designed to match the operating requirements of ion lasers. Details are given in Appendix A: Coherent Cooling Options. Closed-Loop Chiller Chillers have many of the same advantages of heat exchangers insofar as a fixed volume of water is recirculated through the laser. Unlike…

00 Laser Cooling.book

00 Laser Cooling.book

…heat exchanger systems, designed to match the operating requirements of ion lasers. Details are given in Appendix A: Coherent Cooling Options. Closed-Loop Chiller Chillers have many of the same advantages of heat exchangers insofar as a fixed volume of water is recirculated through the laser. Unlike…

00 Laser Cooling.book

00 Laser Cooling.book

…Flow-Through Cooling Systems.....................................................................................10 Closed-Loop Heat Exchanger.........................................................................................11 Closed-Loop Chiller

00 Laser Cooling.book

00 Laser Cooling.book

…Flow-Through Cooling Systems.....................................................................................10 Closed-Loop Heat Exchanger.........................................................................................11 Closed-Loop Chiller

Powered by Site Search powered by SLI Systems

Please Read Before Continuing

Risk factors: Except for the historical information contained here, many of the matters discussed in this Web site are forward-looking statements, based on expectations at the time they were made, that involve risks and uncertainties that could cause our results to differ materially from those expressed or implied by such statements. These risks are detailed in the “Factors That May Affect Future Results” section of our latest 10-K or 10-Q filing. Coherent assumes no obligation to update these forward-looking statements.