Search Results

13 - 24 of 51 Products for 'Cooling Chiller' Page 2 of 5 |

Cooling Chiller

Preinstallation Manual Paladin Advanced Mode Locked UV Laser System

Preinstallation Manual Paladin Advanced Mode Locked UV Laser System

…of the Chiller Line Voltage for Paladin 8W/10W ............................. 3-6
Selection of the Chiller Line Voltage for Paladin 16/24/35 W ......................... 3-8
Cooling System.................................................................................................…

00 LMT Pre.book

00 LMT Pre.book

…planning recommendations.
Liquid Cooling
System
The LMC system requires an external, closed loop water cooling
system. This can be satisfied by a commercially available chiller, or
an existing cooling system. Coherent does not supply chillers, but
can recommend a model…

COHR HighLight DD DS 0819.pdf

COHR HighLight DD DS 0819.pdf

…DUAL LOOP CHILLER (DEIONIZED/DISTILLED)
Chiller Cooling Capacity (kW) >10/10 >16/14
Chiller Water Temp. (°C) 25/25 ±1
Chiller Flow Rate (l/min.) 21/21 42/42
Chiller Water Pressure (psi) 65/50
Chiller Operating Voltage (VAC) 400/460 (±10%)
Chiller Operating…

00 E-250 Pre.book

00 E-250 Pre.book


loops as long as they do not reduce the required flow to the laser, or
they may be cooled by a separate chiller.
Coolant Temperature At the laser head, the inlet temperature of the cooling fluid should
always be above the dew point to prevent condensation from developing inside…

DIAMOND J-3 Series OEM Lasers Preinstallation Manual, Rev. AB

DIAMOND J-3 Series OEM Lasers Preinstallation Manual, Rev. AB


loops as long as they do not reduce the required flow to the laser, or
they may be cooled by a separate chiller.
Coolant Temperature At the laser head, the inlet temperature of the cooling fluid should
always be above the dew point to prevent condensation from developing inside…

DIAMOND J-5 Series OEM Lasers Preinstallation Manual Rev AA

DIAMOND J-5 Series OEM Lasers Preinstallation Manual Rev AA


loops as long as they do not reduce the required flow to the laser, or
they may be cooled by a separate chiller.
Coolant Temperature At the laser head, the inlet temperature of the cooling fluid should
always be above the dew point to prevent condensation from developing inside…

Diamond J-2 Series OEM Lasers Preinstallation Manual, Rev. AB


loops as long as they do not reduce the required flow to the laser, or
they may be cooled by a separate chiller.
Coolant Temperature At the laser head, the inlet temperature of the cooling fluid should
always be above the dew point to prevent condensation from
developing…

Diamond J-3 Series OEM Lasers Preinstallation Manual, Rev. AC

Diamond J-3 Series OEM Lasers Preinstallation Manual, Rev. AC

…7
loops as long as they do not reduce the required flow to the laser, or
they may be cooled by a separate chiller.
Coolant Temperature At the laser head, the inlet temperature of the cooling fluid should
always be above the dew point to prevent condensation from developing inside…

Diamond J-3-5 Series OEM Lasers Preinstallation Manual, Rev. AA

Diamond J-3-5 Series OEM Lasers Preinstallation Manual, Rev. AA


loops as long as they do not reduce the required flow to the laser, or
they may be cooled by a separate chiller.
Coolant Temperature At the laser head, the inlet temperature of the cooling fluid should
always be above the dew point to prevent condensation from developing inside…

DIAMOND J-5V Series OEM Lasers Preinstallation Manual, Rev. AA

DIAMOND J-5V Series OEM Lasers Preinstallation Manual, Rev. AA


loops as long as they do not reduce the required flow to the laser, or
they may be cooled by a separate chiller.
Coolant Temperature At the laser head, the inlet temperature of the cooling fluid should
always be above the dew point to prevent condensation from developing inside…

MetaBEAM1000c Pre.book

MetaBEAM1000c Pre.book

chiller temperature should never be set below the ambient
dew point. Operating in this condition can cause condensation
that will permanently damage the laser tube. Damage caused by
condensation is not covered under warranty.
Table 1-4. Chiller Requirements
CHILLER COOLING

COHR FidelityHP DS 0117 2.pdf

COHR FidelityHP DS 0117 2.pdf


UTILITY REQUIREMENTS
Power Supply 19" rack mount
Electrical Requirements (VAC) 100 to 250, 50 to 60 Hz
Cooling Requirements
Air-cooled closed-loop chiller (included)
External Interfaces RS-232, USB, Sync Out
ENVIRONMENTAL SPECIFICATIONS
Operating Temperature…