COHR AzureNX 266 1000 DS 0618 3.pdf

COHR AzureNX 266 1000 DS 0618 3.pdf

…Laser Head
Power Supply
Chiller
Reciruclator Unit
25
10
20
10
Laser Head Cable Length (m) 5
Operating Thermal Requirements 20 to 33°C
COOLING REQUIREMENTS
Laser Head Water-cooled, closed loop chiller for laser head
Power Supply Air-cooled…

DIAMOND C-20 and C-30 Liquid-Cooled OEM Lasers Preinstallation Manual, Rev. AF

DIAMOND C-20 and C-30 Liquid-Cooled OEM Lasers Preinstallation Manual, Rev. AF

Cooling
The C-20 and C-30 liquid-cooled lasers are cooled by means of liquid
coolant. The cooling system, external to the laser head and the RF power
module, is the responsibility of and must be supplied by the user. A
schematic of the recommended configuration of the cooling

Avia preinstall.book

Avia preinstall.book

…fault protection.
Installing the
Water Chiller
If the water chiller to be used is provided by Coherent (water chiller
available separately) it will have a separate operation manual with
the installation instructions. The chiller will be shipped with plastic
tubing and…

Flyer SLS 200 EN 2017.pdf

Flyer SLS 200 EN 2017.pdf

…kVA 4 kVA 11 kVA 11 kVA Line frequency 50 Hz or 60 Hz Cooling Type of chiller built-in water to air chiller external chiller needed Water inlet max. n/a n/a 20°C / 8 bar 20°C / 8 bar Pressure drop to outlet, min. n/a n/a 4 bar 4 bar Cooling power max. n/a n/a 8.5 kW 8.5 kW Weight / Laser unit 140…

Chameleon Ultra Vision COPO MPX ShutDown PowerUp Procedure.pdf

Chameleon Ultra Vision COPO MPX ShutDown PowerUp Procedure.pdf

…(`6' on figure 5).
Chiller Coolant Drain and Switch off
1.) Switch chiller off using on/off button switch (figure 2).
2.) Connect open ended hose connector to the laser head connector labelled `Cooling Out' as `6' in
figure 4 or Connector labelled `Cooling Out' as `2a' in figure…

COHR Genesis CX SLM-Series DS 0120 3.pdf

COHR Genesis CX SLM-Series DS 0120 3.pdf

…Operating Voltage (VAC) 100 to 240
Frequency (Hz) 50 to 60
Power Consumption (W) 500
Cooling Requirements Heat sink required
Genesis CX Water-Cooled Riser and Chiller, or equivalent
ENVIRONMENTAL CONDITIONS
Ambient Temperature
Operating Condition
Non-Operating…

COHR HighLightDL HPS DS 0819.pdf

COHR HighLightDL HPS DS 0819.pdf

…with integrated water/air chiller that offers unmatched convenience and economy for metal processing applications such as cladding, heat treating, brazing and welding. Also, the HighLightTM DL HPS series uses conduction-cooled diodes which do not require deionized cooling water. Finally, its very…

Biosafety Level 3 setup for multiphoton microscopy in vivo

Biosafety Level 3 setup for multiphoton microscopy in vivo

…piloting the MPM setup by a serial port; and iii/the laser
head to a spectrometer by a USB port. Finally, the recirculation of the cooling fluid from the chiller within the
laser head is made possible by a push-to-connect fitting housed within an airtight thermo-retractable cable gland.…

Discovery ShutDown PowerUp Procedures.pdf

Discovery ShutDown PowerUp Procedures.pdf

…Operators Manual.) In cases where the laser will be switched off for at least 2 weeks,
or it is not practical to leave the chiller and MRU running, the chiller and laser head must also then be
drained. Note that the environmental storage limits should be adhered to during this time.…

COHR PowerLinePico10 DS 1019.pdf

COHR PowerLinePico10 DS 1019.pdf

…6.5 mm
(0.26 in.)
168.0 mm
(6.61 in.)
128.5 mm
(5.06 in.)
139.15 mm
(5.48 in.)
267.0 mm (10.51 in.)
Cooling Air
Z
Z (1:2.5)
PowerLine Pico 10 Datasheet
SPECIFICATIONS PowerLine Pico 10-1064 PowerLine Pico 10-532
Wavelength (nm)…

COHERENT LaserPowerSensors FlowRequirements FittingSpecs PinAssignments 04-2017mp.pdf

COHERENT LaserPowerSensors FlowRequirements FittingSpecs PinAssignments 04-2017mp.pdf

…This can change the flow rate in the sensor and cause erroneous measurements. Adding a sensor head to a laser cooling supply can also cause problems with thermal strain on the cooling system. Fitting and Water Flow Specifications The following flow rates are minimums for proper heat transfer from…

COHR PowerLinePico50 DS 1019.pdf

COHR PowerLinePico50 DS 1019.pdf

…160 100
Pulse Width (ns) 0.5
M2 <1.5
Beam Waist (mm) 3.0 2.0
Controller RCU - ITX
Software VLM 5.2 , Windows 10
Chiller Water/Air-cooling
Dimensions (L x W x H) 360 x 193 x 600 mm (18.53 x 6.61 x 9.57 in.)
Environmental Temperature 15 to 35°C (59 to 95°F)…