Search Results

Refine
1 - 12 of 143 Products for 'Dc 010' Page 1 of 12 |

Dc 010

COHR DC Series DS 0619web.pdf

COHR DC Series DS 0619web.pdf

DC Series Datasheet
MECHANICAL SPECIFICATIONS
DC 010 - DC 025 Standard
Laser Head
9931 00552 -
200 000 166 239 SED 000
20.05.2014 13:45:57
J.PARADOWSKI
17.10.2013
B
C
D
E
F
A
2
1 3 4 5 6 7 8
1 2 3 4 5 6 7 8
B…

UV Optical Components

UV Optical Components

…and many years of experience to deliver the exact solutions you need. Specifications Homogenizer 5 x 5 Homogenizer 10 x 10 Homogenized Field Size (mm) 5 x 5 10 x 10 Zoom (%) ±10 ±10 Homogeneity (%) 80% >80% >80% - - Part No. 157 nm 1116211 1116216 Part No. 193 nm 9680011 1116212 1116217 Part No. 248…

OBIS Laser Cable (0.3 meter)

OBIS Laser Cable (0.3 meter)

…Name Pin System Ground 2, 3, 15, 16 Laser Diode Power (Interlock) 4, 5, 17 +12V DC System Power 6, 18, 19 No Connect 7 Laser Ready Output Signal 8 Baseplate Temperature Output Signal 9 RS-485 Communications 1, 10, 23 Analog Modulation Input 11, 24 Digital Modulation Input 12, 25 SDR In-Use Logic…

OBIS Laser Cable (1 meter)

OBIS Laser Cable (1 meter)

…Name Pin System Ground 2, 3, 15, 16 Laser Diode Power (Interlock) 4, 5, 17 +12V DC System Power 6, 18, 19 No Connect 7 Laser Ready Output Signal 8 Baseplate Temperature Output Signal 9 RS-485 Communications 1, 10, 23 Analog Modulation Input 11, 24 Digital Modulation Input 12, 25 SDR In-Use Logic…

EnergyMax-RS Sensors

EnergyMax-RS Sensors

…operation, for applications such as pulse-to-pulse “A/B” ratiometry. EnergyMax-RS Sensor Model Accessory EnergyMax-RS must be powered with a 5V DC input. This power must be supplied through an external power supply plugged into the external power input plug, or for embedded applications with…

FieldMate

FieldMate

…Measurable Power (with optical sensor) 99.9 mW Min. Measureable Power (with thermopile sensor) 100 µW Min. Measurable Power (with optical sensor) 10 nW Displayable Full-Scale Power Ranges (with thermopile sensor) 29.9 mW to 29.9 kW (auto or manual ranging, selectable) Displayable Full-Scale Power…

COHR DC Series DS 0420.pdf

COHR DC Series DS 0420.pdf

DC Series Datasheet
MECHANICAL SPECIFICATIONS
DC 010 - DC 025 Standard
Laser Head
9931 00552 -
200 000 166 239 SED 000
20.05.2014 13:45:57
J.PARADOWSKI
17.10.2013
B
C
D
E
F
A
2
1 3 4 5 6 7 8
1 2 3 4 5 6 7 8
B…

COHR DiamondCx-10 DS 1119 3.pdf

COHR DiamondCx-10 DS 1119 3.pdf

…stability based on ±(Pmax-Pmin)/(2
*Pmax) measured from cold start for 5 minutes at 25 kHz 99% DC.
4 Power stability based on ±(Pmax-Pmin)/(2
*Pmax) measured for 10 minutes at 25 kHz 99% DC.
5 10% and 90% of peak power fall points measured at 1.5 kHz PRF, 350 µs pulse width, after 5 minutes.…

COHR DIAMOND Cx-10 DS 0118 1.pdf

COHR DIAMOND Cx-10 DS 0118 1.pdf

…stability based on ±(Pmax - Pmin)/(2
*Pmax) measured from cold start for 5 minutes at 25 kHz 99% DC.
4 Power stability based on ±(Pmax - Pmin)/(2
*Pmax) measured for 10 minutes at 25 kHz 99% DC.
5 10% and 90% of peak power fall points measured at 1.5 kHz PRF, 350 µs pulse width, after 5…

DIAMOND Cx-10 Series OEM Laser Preinstallation Manual, Rev. AB

DIAMOND Cx-10 Series OEM Laser Preinstallation Manual, Rev. AB

…< 206 kPa (30 psig)
Coolant Temperature 15ºC - 30°C (59 to 86°F)
Recommended DC Power Cables (2 Red and 2 Black)
DC Cable Length (each) 3 m (10 ft.)
DC Cable Wire Gauge (each) AWG 10
The above values subject to change without notice. Please refer to the data sheet…

COHR Mini DS 1017 3.pdf

COHR Mini DS 1017 3.pdf

…Temperature 10 to 50°C
Storage Temperature -20 to 60°C
MODULATION (sold only with separate driver option)
S (synchro) or RS (reverse synchro)
DC to 10 kHz
Linear for amplitude 1.0 V to 4.0 V
Rise/Fall Time: <10 µs
T (TTL) or RT (Reverse TTL)
DC to 10 kHz…

COHR MagnumII DS 1017 3.pdf

COHR MagnumII DS 1017 3.pdf


MODULATION OPTIONS
S (synchro) or RS (reverse synchro)
DC to 10 kHz
Linear for amplitude 1.0 V to 4.0 V
Rise/Fall Time: <10 µs
T (TTL) or RT (Reverse TTL)
DC to 10 kHz
Rise/Fall Time: <10 µs
Reverse
TTL
Modulation
Vmod (V)