Search Results

49 - 60 of 195 Products for 'Density' Page 5 of 17 |
Related Categories: 340 Nm | Ondax

Density

COHR VarioLas DS 1219 2.pdf

COHR VarioLas DS 1219 2.pdf

…x 2 50 x 0.6
Optical Resolution (µm) 30 5 -
Working Distance (mm) 50 50 150
Max. Repetition Rate (Hz) 100 100 100
Max. Energy Density (J/cm2)
at 193 nm
at 248 nm
at 308 nm
2.5
7.5
6.0
2.5
7.5
6.0
0.5
1.3
1.0
Energy…

COHR UVblade DS 0120 3.pdf

COHR UVblade DS 0120 3.pdf

…solutions for Laser Lift-Off (LLO) separation · Pulse on Demand (POD) · Unmatched beam utilization · Scalability in line lengths and energy density · Felxible system footprint APPLICATIONS · Laser Lift-Off Separation of Wafers and Displays · Unique Lift-Off Solution for Transparent and Colorless…

COHR ExcimerCatalog2020 final lr.pdf

COHR ExcimerCatalog2020 final lr.pdf

…Laser Lift-Off (LLO) separation
· Pulse on Demand (POD)
· Unmatched beam utilization
· Scalability in line lengths and
energy density
· Felxible system footprint
APPLICATIONS
· Laser Lift-Off Separation
of Wafers and Displays
· Unique Lift-Off Solution…

COHR ExcimerCatalog2020 int 0320.pdf

COHR ExcimerCatalog2020 int 0320.pdf

…Laser Lift-Off (LLO) separation
· Pulse on Demand (POD)
· Unmatched beam utilization
· Scalability in line lengths and
energy density
· Flexible system footprint
APPLICATIONS
· Laser Lift-Off Separation
of Wafers and Displays
· Unique Lift-Off Solution…

Industrial Photonics - July 2014

Industrial Photonics - July 2014

…manufacturing challenge. Polymers may be best processed with light of a particular wavelength, while metals may respond best to a specific power density. No matter the material, manufacturing fine features can often be improved with the use of sufficiently short pulses. A look at several examples…

FieldMaxII-TOP User Manual

FieldMaxII-TOP User Manual

…This mode allows the measurement of laser energy in terms of
fluence, and laser power in terms of average power density.
Area calculation returns an average power density reading for
both Flat and Gaussian profiles.
The parameter is entered as a diameter and assumes a circular…

PowerMax-USB-RS-Sensors-Product-Guide.pdf

PowerMax-USB-RS-Sensors-Product-Guide.pdf

…Range (J) 1 to 300
Max. Intermittent Power (<5 min.)(W) 450
Noise Equivalent Power (mW) 20
Maximum Power Density (kW/cm2) 6
Maximum Energy Density (mJ/cm2) 600 (1064 nm, 10 ns)
Response Time (sec.)(o% to 95%)
Speed-up On 2.9
Speed-up Off 11.9
Detector…

Manuscript

Manuscript

…43, 2004.
3. G. J. Steckman, A. Pu, and D. Psaltis, ì Storage density of shift-multiplexed holographic memory,î Applied
Optics, 40, 3387-3394, 2001.
4. G. J. Steckman, A. Pu, and D. Psaltis, ì Storage density of shift-multiplexed holographic memory,î Applied
Optics, 40,…

SureBlock NotchFilter DS.pdf

SureBlock NotchFilter DS.pdf

…selective wavelength applications like low
frequency/THz-Raman spectroscopy. With laser line attenuation
greater than 99.99% (optical density: OD 4) and spectral transition
width of <10 cm-1, SureBlockTM filters can dramatically improve
the ability of any Raman system to…

COHR Fan-CooledThermopileSensors DB25 DS 0719 1.pdf

COHR Fan-CooledThermopileSensors DB25 DS 0719 1.pdf

…Range (J) 1 to 200 1 to 300
Maximum Intermittent Power (<5 min.) (W) 300 450
Resolution (W) 100
Maximum Power Density (kW/cm2) 6
Maximum Energy Density (mJ/cm2) 600, 1064 nm, 10 ns
Response Time (sec.) 2 5 2 5
Detector Coating Broadband
Active Area Diameter (mm)…

COHR Air-CooledThermopileSensors DB25 DS 0819 2.pdf

COHR Air-CooledThermopileSensors DB25 DS 0819 2.pdf

…100 1 to 150 1 to 150
Maximum Intermittent Power (<5 min.) (W) 100 300 300
Resolution (mW) 30
Maximum Power Density (kW/cm2) 6
Maximum Energy Density (mJ/cm2) 600, 1064 nm, 10 ns
Response Time (sec.) 2 5 5
Detector Coating Broadband
Active Area Diameter (mm) 19…

COHR HighPowerWater-CooledThermopileSensors DB25 DS 0719 1.pdf

COHR HighPowerWater-CooledThermopileSensors DB25 DS 0719 1.pdf

…Intermittent Power1 (<5 min.) (W) 3000 5000 10,000
Resolution (W) 1
Maximum Power Density2 (kW/cm2) 1 to 2.5
Maximum Energy Density (mJ/cm2) 600
Response Time (sec.) 30
Detector Coating Broadband
Active Area Diameter (mm) 50
Calibration Uncertainty (%) (k=2)…