COHR DIAMOND C-20 DS 0817 1.pdf

COHR DIAMOND C-20 DS 0817 1.pdf

…ft.)
Humidity Non-condensing
Shipping/Storage Environment -10 to 60°C (14 to 140°F), non-condensing
1 Power measured at 25°C and derated by 1%/C for higher laser head temperatures.
2 Power stability based on ±(Pmax - Pmin)/(2
*Pmax) average power measurement at constant duty cycle…

COHR DIAMOND C-55 DS 0718 1.pdf

COHR DIAMOND C-55 DS 0718 1.pdf

…Pressure
Max. Pressure Differential (at 1.0 gpm)
Coolant Temperature
-
-
-
-
-
1 Power measured at 25°C and derated by 1%/C for higher laser head temperatures.
2 Power stability based on ±(Pmax - Pmin)/(2
*Pmax) average power measurement at constant duty…

COHR DIAMOND C 30 C 30 DS 0619 3.pdf

COHR DIAMOND C 30 C 30 DS 0619 3.pdf

…m (6500 ft.)
Non-Condensing
Shipping/Storage Environment -10 to 60 C (14 to 140 F), Non-Condensing
1 Power measured at 25°C and derated by 1%/C for higher laser head temperatures.
2 Power stability based on ±(Pmax - Pmin)/(2
*Pmax) average power measurement at constant duty cycle…

COHR DIAMOND C 55 C 60 DS 0619 2.pdf

COHR DIAMOND C 55 C 60 DS 0619 2.pdf

…Shipping/Storage Environment -10 to 60 C (14 to 140 F), Non-Condensing
Diamond C-55/C-60+ Series Datasheet
1 Power measured at 25°C and derated by 1%/C for higher laser head temperatures.
2 Power stability based on ±(Pmax - Pmin)/(2
*Pmax) average power measurement at constant duty…

COHR DIAMOND C-30 DS 0817 1.pdf

COHR DIAMOND C-30 DS 0817 1.pdf

…Max. Pressure Differential 1.5 bar (22 psig)
(at 1.0 gpm)
Coolant Temperature 15 to 30°C (59 to 86°F)
1 Power measured at 25°C and derated by 1%/C for higher laser head temperatures.
2 Power stability based on ±(Pmax - Pmin)/(2
*Pmax) average power measurement at constant duty…

COHR DIAMOND C-40 DS 1117 1.pdf

COHR DIAMOND C-40 DS 1117 1.pdf

…Max. Pressure Differential (at 1.0 gpm) - 1.5 bar (22 psig)
Coolant Temperature - 15 to 30°C (59 to 86°F)
1 Power measured at 25°C and derated by 1%/C for higher laser head temperatures.
2 Power stability based on ±(Pmax - Pmin)/(2
*Pmax) average power measurement at constant duty…

COHR DIAMOND C-70 DS 0718 1.pdf

COHR DIAMOND C-70 DS 0718 1.pdf

…Frost
*
>3.8 lpm (1.0 gpm)
7 kg/cm2 (100 psig)
3.2 bar (46 psig)
15 to 30°C (59 to 86°F)
1 Power measured at 25°C and derated by 1%/C for higher laser head temperatures.
2 Power stability based on ±(Pmax - Pmin)/(2
*Pmax) average power measurement at constant duty…

COHR DIAMOND Cx-10 DS 0118 1.pdf

COHR DIAMOND Cx-10 DS 0118 1.pdf

…Max. Pressure Differential (at 1.5 gpm) <206 kPa (30 psig)
Coolant Temperature 15°C - 30°C (59 - 86 oF)
1 Power measured at 25°C and derated by 1%/°C for higher laser head temperature.
2 Power/volume defined as (CW rated power in mW)/(L
*W
*H in cm3).
3 Power stability based on…

Laser Focus World - January 2015

Laser Focus World - January 2015

…arrays of bars. The company's most powerful system produces 10 kW of output
power at 975 nm; internally, it consists
of five bars, each derated to 2 kW to ensure tens of thousands of hours of maintenance-free operation at or above specified power, says Gaebler.
The free-space output…

COHR PowerMax-Pro kW DS 0417 5 FINAL.pdf

COHR PowerMax-Pro kW DS 0417 5 FINAL.pdf

…beams can handle higher powers (~5%) for longer lengths of time, and beams with hot spots or
"super Gaussian" beams the curves must be de-rated by up to 30%. Contacting Coherent LMC applications engineering for more detailed information.
This chart indicates the maximum average power…

COHR WP OPSL Superior Reliability 5.30.18.pdf

COHR WP OPSL Superior Reliability 5.30.18.pdf

…lifetests on 32 random (Coherent Sapphire) OPSLs showing the
extremely long lifetime statistics typical of this technology.
Reliable De-Rated Pump Diodes
A laser is only as reliable and dependable as its components. A key active component in an OPSL
is the pump diode that…

Please Read Before Continuing

Risk factors: Except for the historical information contained here, many of the matters discussed in this Web site are forward-looking statements, based on expectations at the time they were made, that involve risks and uncertainties that could cause our results to differ materially from those expressed or implied by such statements. These risks are detailed in the “Factors That May Affect Future Results” section of our latest 10-K or 10-Q filing. Coherent assumes no obligation to update these forward-looking statements.


I have read the terms and conditions