Search Results

Refine
1 - 12 of 13 Products for 'Detector Pm 3' Page 1 of 2 |

Detector Pm 3

Whitepaper LMC PM-Pro LAM updtd 3 05 19.pdf

Whitepaper LMC PM-Pro LAM updtd 3 05 19.pdf

…density at the precise location the powder layer is being processed, the system
incorporates a Coherent PowerMax-Pro detector. This utilizes a relatively new type of detector
technology called a transverse thermoelectric (Patent #9,059,346), first introduced to the market
in 2014,…

COHR Air-CooledThermopileSensors DB25 DS 1119 3.pdf

COHR Air-CooledThermopileSensors DB25 DS 1119 3.pdf

…nm, 10 ns
Response Time (sec.) 2 2 5
Detector Coating Broadband
Active Area Diameter (mm) 19 19 50
Calibration Uncertainty (%) (k=2) ±1
Calibration Wavelength (nm) 514
Cooling Method Air-cooled
Cable Type PM DB-25
Cable Length (m) 2
Part Number 1098483…

COHR Fan-CooledThermopileSensors DB25 DS 1119 3.pdf

COHR Fan-CooledThermopileSensors DB25 DS 1119 3.pdf

…nm, 10 ns
Response Time (sec.) 2 5 2 5
Detector Coating Broadband
Active Area Diameter (mm) 19 50 19 50
Calibration Uncertainty (%) (k=2) ±1
Calibration Wavelength (nm) 514
Cooling Method Fan-cooled
Cable Type PM DB-25
Cable Length (m) 2
Part Number…

COHERENT LMC 2016-2017 Catalog .pdf

COHERENT LMC 2016-2017 Catalog .pdf

…1W - 100 Broadband 1064 3 PM DB-25
1098506 PM3K-100 0.25 to 11.0 100W 3000W 1W - 100 Broadband 1064 3 PM DB-25
1098461 PM5K-100 0.25 to 11.0 100W 5000W 1W - 100 Broadband 1064 3 PM DB-25
1098505 PM5K-200 0.25 to 11.0 100W 5000W 1W - 200 Broadband 1064 3 PM DB-25
Position-Sensing…

COHR PowerMax BBplus kW Sensors DS 0120 2.pdf

COHR PowerMax BBplus kW Sensors DS 0120 2.pdf

Detector Diameter (mm) 50 50 50
Calibration Uncertainty (%) ±3 ±3 ±3
Power Linearity (%) ±2 ±2 ±2
Spectral Compensation Accuracy (%) ±1.5 ±1.5 ±1.5
Calibration Wavelength (nm) 1070 and 10,600 1070 and 10,600 1070 and 10,600
Cooling Method Water Water Water
Cable Type PM

COHR Air-CooledThermopileSensors DB25 DS 0819 2.pdf

COHR Air-CooledThermopileSensors DB25 DS 0819 2.pdf

…nm, 10 ns
Response Time (sec.) 2 5 5
Detector Coating Broadband
Active Area Diameter (mm) 19 50 50
Calibration Uncertainty (%) (k=2) ±1
Calibration Wavelength (nm) 514
Cooling Method Air-cooled
Cable Type PM DB-25
Cable Length (m) 2
Part Number 1098483…

COHR Fan-CooledThermopileSensors DB25 DS 0719 1.pdf

COHR Fan-CooledThermopileSensors DB25 DS 0719 1.pdf

…nm, 10 ns
Response Time (sec.) 2 5 2 5
Detector Coating Broadband
Active Area Diameter (mm) 19 50 19 50
Calibration Uncertainty (%) (k=2) ±1
Calibration Wavelength (nm) 514
Cooling Method Fan-cooled
Cable Type PM DB-25
Cable Length (m) 2
Part Number…

COHR Fan-CooledThermopileSensors DB25 DS 0919 2.pdf

COHR Fan-CooledThermopileSensors DB25 DS 0919 2.pdf

…nm, 10 ns
Response Time (sec.) 2 5 2 5
Detector Coating Broadband
Active Area Diameter (mm) 19 50 19 50
Calibration Uncertainty (%) (k=2) ±1
Calibration Wavelength (nm) 514
Cooling Method Fan-cooled
Cable Type PM DB-25
Cable Length (m) 2
Part Number…

COHR HighPowerWater-CooledThermopileSensors DB25 DS 0719 1.pdf

COHR HighPowerWater-CooledThermopileSensors DB25 DS 0719 1.pdf

…Density (mJ/cm2) 600
Response Time (sec.) 30
Detector Coating Broadband
Active Area Diameter (mm) 50
Calibration Uncertainty (%) (k=2) ±3
Calibration Wavelength (nm) 1070
Cooling Method Water
Cable Type PM DB-25
Cable Length (m) 2
Part Number 10983923…

COHR HighPowerWater-CooledThermopileSensors DB25 DS 1119 2.pdf

COHR HighPowerWater-CooledThermopileSensors DB25 DS 1119 2.pdf

…Density (mJ/cm2) 600
Response Time (sec.) 30
Detector Coating Broadband
Active Area Diameter (mm) 50
Calibration Uncertainty (%) (k=2) ±3
Calibration Wavelength (nm) 1070
Cooling Method Water
Cable Type PM DB-25
Cable Length (m) 2
Part Number 10983923…

DIAMOND J-5V Series OEM Lasers Preinstallation Manual, Rev. AA

DIAMOND J-5V Series OEM Lasers Preinstallation Manual, Rev. AA

Preliminary: December 18, 2015 12:56 pm Utility Requirements and System Installation
3 - 7
A typical flow diagram is shown in Figure 3-1. The delivery system
and/or laser power detector may be connected in parallel auxiliary
loops as long as they do not reduce the required flow…

Quotation KML QGYYMMDD G  Institute Contact

Quotation KML QGYYMMDD G Institute Contact

…TJ Silva, M Aeschlimann, HC Kapteyn, MM Murnane, CM Schneider, and PM
Oppeneer, "Ultrafast magnetization enhancement in metallic multilayers driven by superdiffusive
spin current," Nature Communications 3, 1037 (2012). dx.doi.org/10.1038/ncomms2029