Diamond J 5 Coolant

DIAMOND J-5 Series OEM Lasers Preinstallation Manual Rev AA

DIAMOND J-5 Series OEM Lasers Preinstallation Manual Rev AA


Protection
The recommended coolant mixture does not provide freeze
protection; therefore the coolant temperature must be maintained
above the freezing point of water. Since lower temperatures may
occur during shipment and storage, the DIAMOND J-5 Series laser
system (or…

COHR DIAMOND J-3-5 COlaser DS 0617 2.pdf

COHR DIAMOND J-3-5 COlaser DS 0617 2.pdf


Coolant Temperature Stability (max.) ±1.0°C (±1.8°F)
Coolant9 Anti-corrosion treated water
Coolant Differential Pressure10 (kPa) 103 (15 psi) at 5.7 l/min. (1.5 gpm)
Coolant Maximum Static Pressure (kPa) 827 (120 psi)
ENVIRONMENTAL CONDITIONS
Ambient Temperature 5 to…

COHR DIAMOND J-5 DS 1117 1.pdf

COHR DIAMOND J-5 DS 1117 1.pdf


Coolant Temperature Stability (max.) ±1.0°C (±1.8°F)
Coolant9 Anti-corrosion treated water
Coolant Differential Pressure10 (kPa) 241 (35 psi) at 9.5 l/min. (2.5 gpm)
Coolant Maximum Static Pressure (kPa) 827 (120 psi)
ENVIRONMENTAL CONDITIONS
Ambient Temperature 5 to…

COHR DIAMOND J-3 DS 0617 1.pdf

COHR DIAMOND J-3 DS 0617 1.pdf


Coolant Temperature Stability (max.) ±1.0°C (±1.8°F)
Coolant9 Anti-corrosion treated water
Coolant Differential Pressure10 (kPa) 103 (15 psi) at 5.7 l/min. (1.5 gpm)
Coolant Maximum Static Pressure (kPa) 827 (120 psi)
ENVIRONMENTAL CONDITIONS
Ambient Temperature 5 to…

Diamond J-3-5 Series OEM Lasers Preinstallation Manual, Rev. AA

Diamond J-3-5 Series OEM Lasers Preinstallation Manual, Rev. AA

…of the recommended coolant mixture do not provide freeze
protection; therefore the coolant temperature must be maintained
above the freezing point of water for those coolant mixtures. Since
lower temperatures may occur during shipment and storage, the
DIAMOND J-3-5 Series laser…

Diamond J-5 Series OEM Lasers Preinstallation Manual, Rev. AC

DIAMOND J-5 Series OEM Laser Operator's Manual
3 - 8
Figure 3-2 shows system components from water circuits treated
with inhibitor and a water circuit without inhibitor.
Freeze/Burst
Protection
The recommended coolant mixture does not provide freeze
protection;…

Diamond J-2 Series OEM Lasers Preinstallation Manual, Rev. AB

DIAMOND J-2 Series OEM Lasers Preinstallation Manual
1 - 10
4 - High Current Hazard Warning Label
5 - Drainage Warning Label
6 - Coolant Requirement Warning Label
7 - Tipping Warning Label
Figure 1-3. Labels (Continued)
WARNING
HIGH CURRENT
HAZARD.

Diamond J-3 Series OEM Lasers Preinstallation Manual, Rev. AC

Diamond J-3 Series OEM Lasers Preinstallation Manual, Rev. AC

…Purge Gas" on page 3-11 for
additional information on purging the laser head.
Coolant Inlet Connection for the cooling fluid hose that supplies coolant from the coolant
source.
Coolant Outlet Connection for the cooling fluid hose. Cooling fluid travels from the laser head

DIAMOND J-3 Series OEM Lasers Preinstallation Manual, Rev. AB

DIAMOND J-3 Series OEM Lasers Preinstallation Manual, Rev. AB

…Purge Gas" on page 3-10 for
additional information on purging the laser head.
Coolant Inlet Connection for the cooling fluid hose that supplies coolant from the coolant
source.
Coolant Outlet Connection for the cooling fluid hose. Cooling fluid travels from the laser head

DIAMOND J-5V Series OEM Lasers Preinstallation Manual, Rev. AA

DIAMOND J-5V Series OEM Lasers Preinstallation Manual, Rev. AA


SPATIAL FILTER
CORRECTING LENS
BEAM TURNING
MIRRORS
COOLANT
MANIFOLDS
PURGE INPUT
COOLANT OUT
+ 48 VDC
CONTROL/DIAGNOSTIC
MODULE
RF POWER MODULE
COOLANT IN
OPTICAL SHUTTER MODULE
MATCHING
NETWORK
ACCESS COVER

COHR DiamondJ-5 DS 0119 1.pdf

COHR DiamondJ-5 DS 0119 1.pdf


Coolant Temperature Stability (max.) ±1.0°C (±1.8°F)
Coolant9 Anti-corrosion treated water
Coolant Differential Pressure10 (kPa) 241 (35 psi) at 9.5 l/min. (2.5 gpm)
Coolant Maximum Static Pressure (kPa) 827 (120 psi)
ENVIRONMENTAL CONDITIONS
Ambient Temperature 5 to…

COHR DiamondJ-2 DS 0518 2.pdf

COHR DiamondJ-2 DS 0518 2.pdf


Coolant Temperature Stability (max.) ±1.0°C (±1.8°F)
Coolant9 Anti-corrosion treated water
Coolant Differential Pressure10 (kPa) 103 (15 psi) at 5.7 l/min. (1.5 gpm)
Coolant Maximum Static Pressure (kPa) 827 (120 psi)
ENVIRONMENTAL CONDITIONS
Ambient Temperature 5 to…