Search Results

Refine

Result Type

1 - 12 of 14 Products for 'Diamond Shutter' Page 1 of 2 |
Related Categories: J5 | Co2 Laser J5 | J-5-9.4 | Co2 J5 | Rf Excited Co2 Laser

Diamond Shutter

COHR DIAMOND J-5 DS 1117 1.pdf

COHR DIAMOND J-5 DS 1117 1.pdf

Diamond J-5 Series Datasheet
SPECIFICATIONS Diamond Diamond Diamond Diamond
J-5-9.4 J-5-10.2 J-5-10.6 J-5-10.6NB
Wavelength (m) 9.36 ±0.05 10.25 ±0.5 10.2 to 10.8 10.6 ±0.05
Output Power2 (W) 400 400 450 450
Power Range3 (W) 40 to 400 40 to 400 45 to 450 45 to 450

Diamond g50 100 Quiksetup.pdf

Diamond g50 100 Quiksetup.pdf

…ein und
geben Sie dieses Signal an den TTL-Pulseingang.
6. Stellen Sie sicher, daß am Laserstrahlaustritt ein Leistungsmeßgerät oder ein Shutter installiert ist.
7. Legen Sie das Modulationssignal an und beobachten
Sie die Pulse.
ABMESSUNGEN
171.5 mm
(6.75 in)

DIAMOND J-5 Series OEM Lasers Preinstallation Manual Rev AA

DIAMOND J-5 Series OEM Lasers Preinstallation Manual Rev AA

…Required
Shutter Interlock Enables shutter operation Required
*
OUTPUT SIGNALS
Shutter Closed Status Signals that shutter is closed Recommended
*
Shutter Open Status Signals that shutter is open Recommended
*
Shutter Latching Fault Indicates a shutter fault Recommended
*…

COHR DiamondFLC DS 0318 4.pdf

COHR DiamondFLC DS 0318 4.pdf

Diamond FLC-Series Datasheet
SPECIFICATIONS Diamond FLC-100 Diamond FLC-200
Wavelength1 (nm) 1070 1070
Output Power (W) (maximum) 100 200
Modulation Frequency (kHz) 0 to 170 0 to 170
Mode of Operation CW/Modulated CW/Modulated
Beam Diameter2 (mm) (1/e2) 5 ±0.5 5 ±0.5…

Diamond J-2 Series OEM Lasers Preinstallation Manual, Rev. AB

DIAMOND J-2 Series OEM Lasers Preinstallation Manual
4 - 20
Extended
Interface Signal
Descriptions
NOTICE!
The optional shutter is provided for laser safety purpose only.
This shutter is not to be used for beam modulation (as a `process
shutter').
Table…

DIAMOND J-5V Series OEM Lasers Preinstallation Manual, Rev. AA

DIAMOND J-5V Series OEM Lasers Preinstallation Manual, Rev. AA

DIAMOND J-5V Series OEM Lasers Preinstallation Manual Preliminary: December 18, 2015
4 - 20
Extended
Interface Signal
Descriptions
NOTICE!
The optional shutter is provided for laser safety purpose only.
This shutter is not to be used for beam modulation (as a…

DIAMOND J-3 Series OEM Lasers Preinstallation Manual, Rev. AB

DIAMOND J-3 Series OEM Lasers Preinstallation Manual, Rev. AB

…Required
Shutter Interlock Enables shutter operation Required
*
OUTPUT SIGNALS
Shutter Closed Status Signals that shutter is closed Recommended
*
Shutter Open Status Signals that shutter is open Recommended
*
Shutter Latching Fault Indicates a shutter fault Recommended
*…

Diamond J-3 Series OEM Lasers Preinstallation Manual, Rev. AC

Diamond J-3 Series OEM Lasers Preinstallation Manual, Rev. AC

…Required
Shutter Interlock Enables shutter operation Required
*
OUTPUT SIGNALS
Shutter Closed Status Signals that shutter is closed Recommended
*
Shutter Open Status Signals that shutter is open Recommended
*
Shutter Latching Fault Indicates a shutter fault Recommended
*…

Diamond J-3-5 Series OEM Lasers Preinstallation Manual, Rev. AA

Diamond J-3-5 Series OEM Lasers Preinstallation Manual, Rev. AA

…Required
Shutter Interlock Enables shutter operation Required
*
OUTPUT SIGNALS
Shutter Closed Status Signals that shutter is closed Recommended
*
Shutter Open Status Signals that shutter is open Recommended
*
Shutter Latching Fault Indicates a shutter fault Recommended
*…

Diamond J-5 Series OEM Lasers Preinstallation Manual, Rev. AC

…Required
Shutter Interlock Enables shutter operation Required
*
OUTPUT SIGNALS
Shutter Closed Status Signals that shutter is closed Recommended
*
Shutter Open Status Signals that shutter is open Recommended
*
Shutter Latching Fault Indicates a shutter fault Recommended
*…

00 E-250 Pre.book

00 E-250 Pre.book

DIAMOND E-250 Series OEM Lasers Preinstallation Manual
4 - 18
Extended
Interface Signal
Descriptions
NOTICE!
The optional shutter is provided for laser safety purpose only.
This shutter is not to be used for beam modulation (as a `process
shutter').
Table…

00 E-1000 PreInst.book

00 E-1000 PreInst.book

…Detected - Reset Faults State
NODE FAULTS (0X01-0X7F)
RFPS SWR 0x01 RF SWR exceeds maximum
Shutter Interlock 0x02 Shutter Interlock Open
Shutter Transition 0x03 Shutter Transition Failure
Node Temperature 0x04 Node Temperature Out of Range
Node Dew Point 0x05 Node Dew…

Please Read Before Continuing

Risk factors: Except for the historical information contained here, many of the matters discussed in this Web site are forward-looking statements, based on expectations at the time they were made, that involve risks and uncertainties that could cause our results to differ materially from those expressed or implied by such statements. These risks are detailed in the “Factors That May Affect Future Results” section of our latest 10-K or 10-Q filing. Coherent assumes no obligation to update these forward-looking statements.


I have read the terms and conditions