Search Results

1 - 12 of 14 Products for 'Discovery Tpc' Page 1 of 2 |

Discovery Tpc

Chameleon Discovery NX w/ Total Power Control

Chameleon Discovery NX w/ Total Power Control

…> Visit the MPE OASIS page Datasheet Chameleon Discovery NX Datasheet Chameleon Discovery NX TPC Datasheet Chameleon Discovery VUE Harmonics Datasheet Levante IR OPO Drawing Chameleon Discovery NX and Discovery NX with TPC Chameleon Discovery (CN) Applications Application Process Life Sciences…

COHR ChameleonDiscoveryNX DS 1019 4.pdf

COHR ChameleonDiscoveryNX DS 1019 4.pdf

Chameleon Discovery NX Datasheet
UTILITY REQUIREMENTS Chameleon Discovery NX
Operating Voltage (VAC) 90 to 250 (auto ranging)
Maximum Operating Current (A)
Power Supply
Chiller
MRU
<8 at 90 VAC
<14 at 90 VAC
<2 at 90 VAC
System Power…

COHR ChameleonDiscovery TPC DS 1117 5.pdf

COHR ChameleonDiscovery TPC DS 1117 5.pdf

…Chameleon Discovery Datasheet
Chameleon Discovery with TPC: Typical Tuning and Power
Average Power (mW)
0
500
1000
1500
2000
650
Wavelength (nm)
750 850 950 1050 1150 1250 1350
MECHANICAL SPECIFICATIONS
Chameleon Discovery
with Total…

COHR ChameleonDiscoveryNX TPC DS 1019 4.pdf

COHR ChameleonDiscoveryNX TPC DS 1019 4.pdf


3000
650
Wavelength (nm)
750 850 950 1050 1150 1250 1350
Chameleon Discovery NX TPC:
Typical Tuning and Power
Chameleon Discovery NX TPC:
Beam Profile at 1000 nm
TYPICAL PERFORMANCE DATA
Chameleon Discovery NX with Total Power Control Datasheet

COHR ChameleonDiscoveryNX TPC DS 1019 5.pdf

COHR ChameleonDiscoveryNX TPC DS 1019 5.pdf


3000
650
Wavelength (nm)
750 850 950 1050 1150 1250 1350
Chameleon Discovery NX TPC:
Typical Tuning and Power
Chameleon Discovery NX TPC:
Beam Profile at 1000 nm
TYPICAL PERFORMANCE DATA
Chameleon Discovery NX with Total Power Control Datasheet

COHR ChameleonDiscoveryNX TPC DS 0120 6.pdf

COHR ChameleonDiscoveryNX TPC DS 0120 6.pdf


3000
650
Wavelength (nm)
750 850 950 1050 1150 1250 1350
Chameleon Discovery NX TPC:
Typical Tuning and Power
Chameleon Discovery NX TPC:
Beam Profile at 1000 nm
TYPICAL PERFORMANCE DATA
Chameleon Discovery NX with Total Power Control Datasheet

COHR ChameleonDiscovery TPC DS 1218 2.pdf

COHR ChameleonDiscovery TPC DS 1218 2.pdf

Chameleon Discovery with Total Power Control Datasheet
MECHANICAL SPECIFICATIONS
Chameleon Discovery
with Total Power Control
Chameleon Discovery with TPC:
Typical Tuning and Power
TYPICAL PERFORMANCE DATA
120.8 mm
(4.76 in.)
286.7 mm
(11.29 in.)…

Chameleon and TPC Drawings 11 09 17

Chameleon and TPC Drawings 11 09 17

Chameleon Discovery 120.8 mm (4.76 in.) 286.7 mm (11.29 in.) 445.2 mm (17.53 in.) 820.8 mm (32.31 in.) 259.9 mm (10.23 in.) 329.3 mm (12.96 in.) Top View Side View Front View

COHR ChameleonDiscoveryVUE DS 0518 5.pdf

COHR ChameleonDiscoveryVUE DS 0518 5.pdf

…AVERAGE POWER: 10W
EMITTED WAVELENGTH: 200-600 nm
PULSE DURATION: 10 fs - CW
Chameleon Discovery VUE Harmonics Datasheet
SPECIFICATIONS Chameleon Discovery Chameleon Discovery TPC
Tuning Range (nm) 330 to 660 340 to 650
Conversion Efficiency1 (%) >35
MECHANICAL…

Higher Power Nanosecond Lasers Cut Thicker Films, PCBs, and Flex Substrates

Higher Power Nanosecond Lasers Cut Thicker Films, PCBs, and Flex Substrates

…maximize image depth. Chameleon Discovery NX provides several other industry-leading benefits: It boasts tuning from 660 nm to 1320 nm, while simultaneously producing a high-power fixed wavelength output at 1040 nm. It is also available with Total Power Control (TPC), enabling built-in high-speed…

COHR ChameleonDiscoveryNX DS 1019 5.pdf

COHR ChameleonDiscoveryNX DS 1019 5.pdf

Chameleon Discovery NX Datasheet
UTILITY REQUIREMENTS Chameleon Discovery NX
Operating Voltage (VAC) 90 to 250 (auto ranging)
Maximum Operating Current (A)
Power Supply
Chiller
MRU
<8 at 90 VAC
<14 at 90 VAC
<2 at 90 VAC
System Power…