Search Results

1 - 12 of 96 Products for 'Fall Time' Page 1 of 8 |
Related Categories: Cx 10 | C70 | Low Power Co2 Laser | C55 | Diamond Co2

Fall Time

DIAMOND C-Series

DIAMOND C-Series

…These lasers include an integrated acoustic optical modulator providing superior pulse control and extremely fast pulse fall times. The Cx-10LDE+ provides <1 µs fall times and the Cx-10LQS delivers high peak power with ≤200 ns pulse widths. The C-55 and C-70 lasers, are specified at 55W and 70W…

Book.book

Book.book


Rise and Fall Time (10 to 90%)
Modulation Depth at 0 Hz
Modulation Depth at 150 MHz
Input Impedance
150 MHz
< 2 nsec
*
> 1,000,000:1 (106:1)
> 250:1
50 ohms
Analog Modulation
Maximum Bandwidth
Rise and Fall Time (10 to 90%)

Lasers | Photonics Handbook®

Lasers | Photonics Handbook®

…trip; a
fraction of them (~20-40%) get coupled by the partly transmissive mirror. The result is a pulse with a very sharp raising time and a slower falling time, with a
typical duration of 1 to 200 ns. The pulse duration depends on several parameters: the type of gain medium and how much…

DIAMOND E-Series

DIAMOND E-Series

…And the E-1000 Series can be operated with pulse repetition rates up to 200 kHz with fast pulse rise and fall times. This combination of high peak power and fast rise and fall time times, together with power on demand and excellent beam quality makes the E-1000 Series an ideal laser for a wide…

kW PowerMax Pro Sensor

kW PowerMax Pro Sensor

…Speed Mode (20 kHz) <0.5W Snapshot Mode (625 kHz) <1.5W Maximum Power Density (kW/cm²) 5.0 at 1 kW avg. power 2.4 at 3 kW avg. power Rise Time (μs) ≤20 Fall Time (μs) ≤20 Protective Front Window Available for 1070 nm model (see part number below) Active Area (mm) Axis 30 (element is 57 mm from front…

PowerMax-Pro USB/RS Sensors

PowerMax-Pro USB/RS Sensors

…Density (J/cm²) 33 (10 ns; 1064 nm) 33 (10 ns; 1064 nm) 33 (10 ns; 1064 nm) 33 (10 ns; 1064 nm) 33 (10 ns; 1064 nm) 33 (10 ns; 1064 nm) Rise & Fall Time (μs) ≤10 ≤350 ≤10 ≤350 ≤50 ≤50 Detector Coating HD HD HD HD BB BB Active Area (mm) 30 x 30 30 x 30 30 x 30 30 x 30 30 x 30 30 x 30 Minimum Beam…

Life Sciences and Medical Applications

Life Sciences and Medical Applications

…maximum read length, and cost-effectiveness. These methods feature incredible parallelism that has enabled the cost of genome sequencing to fall by several orders of agnitude in less than 25 years. At present, the most popular of these techniques all rely on laser illumination of fluorescently…

LabMax-Pro Mobile for Android User Guide

LabMax-Pro Mobile for Android User Guide

LabMax-Pro Mobile for Android User Guide
14
Pulse Analysis Settings: Defines the reference levels for
the pulse analytics (for example, rise time, fall time, and
pulse width). Rise time is usually measured from 10 to
90%.
Global
Settings
Menu

LabMax-Pro Mobile for iOS User Guide

LabMax-Pro Mobile for iOS User Guide

Setting Software Options
13
Pulse Analysis Settings: Defines the reference levels for
the pulse analytics (for example, rise time, fall time, and
pulse width). Rise time is usually measured from 10 to
90%.
Global
Settings
Menu

book.book

book.book

…Digital TTL(RT)
Maximum bandwidth 100 KHz
Rise time (10% to 90%) <1 msec
Fall time (90% to 10%) <1 msec
Reverse Fast Digital TTL(RFT)
Maximum bandwidth 2 MHz
Rise time (10% to 90%) <150 nsec
Fall time (90% to 10%) <150 nsec
Figure 3-7. Reverse…

COHR StingRay BioRay DS 0618 3.pdf

COHR StingRay BioRay DS 0618 3.pdf

…to 5V is 100% output power
Maximum bandwidth of 100 KHz
Rise time (10% to 90%) <1 msec
Fall time (90% to 10%) <1 msec
Maximum bandwidth of 2 MHz
Rise time (10% to 90%) <150 nsec
Fall time (90% to 10%) <150 nsec
Reverse Digital TTL (RT)
Reverse Fast…

COHR StingRay BioRay DS 0119 3.pdf

COHR StingRay BioRay DS 0119 3.pdf

…to 5V is 100% output power
Maximum bandwidth of 100 KHz
Rise time (10% to 90%) <1 msec
Fall time (90% to 10%) <1 msec
Maximum bandwidth of 2 MHz
Rise time (10% to 90%) <150 nsec
Fall time (90% to 10%) <150 nsec
Reverse Digital TTL (RT)
Reverse Fast…