Search Results

1 - 12 of 46 Products for 'Ghz' Page 1 of 4 |

Ghz

EnergyMax-USB/RS User Manual

EnergyMax-USB/RS User Manual

…can capture and measure every single pulse, as well as send data to
the computer. Most dual-core and quad-core computers faster than 2
GHz can process the data and analyze every pulse--even at high
repetition rates--using the full graphical and statistical features of
the…

Mephisto/Mephisto-S

Mephisto/Mephisto-S

…Wavelength 1064 nm 1319 nm 1064 nm Power .5W, 1W, 2W .2W, .5W, .8W .2W, .5W Linewidth (over 100 ms) ~ 1 kHz ~ 1 kHz kHz range Tuning range 30 GHz 30 GHz 30 GHz Noise (RIN at f>10 kHz) <-140 dB/Hz <-140 dB/Hz <-120 dB/Hz Ultra-Narrow Linewidth Single-Frequency CW Laser - Mephisto lasers are available…

Prometheus

Prometheus

…stabilization options. Prometheus Wavelength 532 nm, 1064 nm Power at 532 nm 20mW, 50mW, 100mW Linewidth (over 100 ms) ~1 kHz Tuning range 60 GHz Noise (RIN at f>10 kHz) Ultra-Narrow Linewidth CW DPSS Green Laser - Prometheus laser, as the whole Mephisto family, is based on a Non-Planar Ring…

Mephisto Lasers

Mephisto Lasers

….5W, .8W .2W, .5W 8W, 25W, 42W, 55W 20mW, 50mW, 100mW Linewidth (over 100 ms) ~ 1 kHz ~ 1 kHz kHz range ~1 kHz ~1 kHz Tuning range 30 GHz 30 GHz 30 GHz 30 GHz 60 GHz Noise (RIN at f>10 kHz ) <-140 dB/Hz <-140 dB/Hz <-120 dB/Hz <-130 dB/Hz <-135 dB/Hz Call +1 800 527 3786 Outside the U.S. +1 408 764…

Mephisto MOPA Lasers

Mephisto MOPA Lasers

…into the properties of the high-power beam of Mephisto MOPA (linewidth, stability, frequency tuning). Mephisto MOPA can be tuned over a 30 GHz range and be fine-tuned using temperature and PZT controls of the integrated Mephisto laser. Datasheet Mephisto MOPA Drawing Mephisto MOPA Applications…

THz-Raman® Spectroscopy Systems

THz-Raman® Spectroscopy Systems

…capital, training, and maintenance costs. The THz-Raman spectral region covers both Stokes and anti-Stokes signals from ±5 cm-1to 200 cm-1, (or 150 GHz to 6 THz), which contain important structural information about the molecule or crystal lattice. This region reveals a new “structural fingerprint”…

THz-Raman® Spectroscopy Microscope Module

THz-Raman® Spectroscopy Microscope Module

…Bio-instrumentation Polymorph Identification --> Features & Benefits Features
* Fast collection of THz-Raman spectra from 5 cm -1 to >3000 cm -1 (150 GHz to 90 THz)
* Simultaneous Stokes and anti-Stokes signals improve SNR while providing inherent calibration reference
* Available as add-on to…

THz-Raman® Spectroscopy Benchtop Module

THz-Raman® Spectroscopy Benchtop Module

…Fiber-coupled output enables easy interface to a wide range of spectrometers
* Fast collection of THz-Raman spectra from 5 cm -1 to >3000 cm -1 (150 GHz to 90 THz)
* Simultaneous Stokes and anti-Stokes signals improve SNR while providing inherent calibration reference
* Can be added on to an…

SureBlock™ XLF Notch Filter Systems

SureBlock™ XLF Notch Filter Systems

…Notch Filter Systems enable fast, clear capture of Raman spectra in the Low-Frequency/Low Wavenumber/THz regime (~5 cm -1 to 200 cm -1, or 150 GHz to 6 THz), as well as the standard chemical fingerprint region, using only a standard single-stage spectrometer. THz-Raman ® is powerful new technique…

Volume Holographic Grating Filters (VHG)

Volume Holographic Grating Filters (VHG)

…XLF Notch Filter Systems enable fast, clear capture of Raman spectra in the Low-Frequency/Low Wavenumber/THz regime (~5 cm-1 to 200 cm-1, or 150 GHz to 6 THz), as well as the standard chemical fingerprint region, using only a standard single-stage spectrometer. Call +1 800 527 3786 Outside the…

EnergyMax-USB/RS Sensors

EnergyMax-USB/RS Sensors

…This is useful for burn-in stations. (Note: Due to the high data rate it is recommended to use a basic ~$600-700 Quad Core processor of about 2.5 GHz or faster when operating more than one unit, otherwise the display update rate will slow down.)
* Flexible sample collection and batch size selection…

EnergyMax-USB/RS Sensors

EnergyMax-USB/RS Sensors

…This is useful for burn-in stations. (Note: Due to the high data rate it is recommended to use a basic ~$600-700 Quad Core processor of about 2.5 GHz or faster when operating more than one unit, otherwise the display update rate will slow down.)
* Flexible sample collection and batch size selection…

Please Read Before Continuing

Risk factors: Except for the historical information contained here, many of the matters discussed in this Web site are forward-looking statements, based on expectations at the time they were made, that involve risks and uncertainties that could cause our results to differ materially from those expressed or implied by such statements. These risks are detailed in the “Factors That May Affect Future Results” section of our latest 10-K or 10-Q filing. Coherent assumes no obligation to update these forward-looking statements.


I have read the terms and conditions