DIAMOND J-3 Series OEM Lasers Preinstallation Manual, Rev. AB

DIAMOND J-3 Series OEM Lasers Preinstallation Manual, Rev. AB

…geographical
locations outside the
US
Dowfrost Dow Chemical Inc.
www.dow.com
989-636-1000
Inhibited
Propylene
Glycol and
Water
30% in water At 30% mix will
provide burst
protection to
--25°C (13°F)
See Note below
Table 3-3.…

Microsoft Word - AppNote012.doc

Microsoft Word - AppNote012.doc

…WARRANTY ON THE PRODUCT. Coolant 1. Tap or distilled water is recommended. 2. Do not use Dl water, as it will dissolve aluminum and brass. 3. Ethylene Glycol is okay up to a 10% maximum in the mixture. 4. Allow sufficient time for the water flow and detector head to reach equilibrium. The water flow…

00 Laser Cooling.book

00 Laser Cooling.book


Approved plant water
additives
None
Not designed
for seawater.
Glycol OK.
Not designed
for seawater.
Glycol OK.
Not designed
for seawater.
Glycol OK.
Not designed
for seawater.
None
Not designed
for seawater.

Diamond J-2 Series OEM Lasers Preinstallation Manual, Rev. AB

…geographical
locations outside the
US
Dowfrost Dow Chemical Inc.
www.dow.com
989-636-1000
Inhibited
Propylene
Glycol and
Water
30% in water At 30% mix will
provide burst
protection to
- 25°C (- 13°F)
See Note below
Table 3-3.…

Diamond J-3 Series OEM Lasers Preinstallation Manual, Rev. AC

Diamond J-3 Series OEM Lasers Preinstallation Manual, Rev. AC

…geographical
locations outside the
US
Dowfrost Dow Chemical Inc.
www.dow.com
989-636-1000
Inhibited
Propylene
Glycol and
Water
30% in water At 30% mix will
provide burst
protection to
--25°C (13°F)
See Note below
Table 3-3.…

Diamond J-3-5 Series OEM Lasers Preinstallation Manual, Rev. AA

Diamond J-3-5 Series OEM Lasers Preinstallation Manual, Rev. AA

…geographical
locations outside the
US
Dowfrost Dow Chemical Inc.
www.dow.com
989-636-1000
Inhibited
Propylene
Glycol and
Water
30% in water At 30% mix will
provide burst
protection to
-25°C (13°F)
See Note below
Table 3-3.…

COHERENT LaserPowerSensors FlowRequirements FittingSpecs PinAssignments 04-2017mp.pdf

COHERENT LaserPowerSensors FlowRequirements FittingSpecs PinAssignments 04-2017mp.pdf

…is relatively stable. The water can be supplied from a chiller or local tap. Do not use DI water, as it will dissolve aluminum and brass. Ethylene Glycol is okay up to a 10% maximum in the mixture. Allow sufficient time for the water flow and sensor head to reach equilibrium. The water flow should…