Search Results

1 - 12 of 21 Products for 'Interferometer' Page 1 of 2 |

Interferometer

SureLock 633 nm Wavelength Stabilized Laser Diode

SureLock 633 nm Wavelength Stabilized Laser Diode

…operating power, narrowed linewidth, low power consumption, and broad temperature operating characteristics make it ideal for next-generation interferometer and analytical instrument designs, with 10x the power and 1/100 th the size of a comparable HeNe laser. All SureLock™ Series lasers are…

Mira Family

Mira Family

…GVD compensation, resulting in shortened and stabilized ‘soliton-like’ pulses. In the Mira Optima 900-P (picosecond version) a Gires-Tournois Interferometer (GTI) conveniently supplies the compensation. Easy to Use Performance The combination of Coherent’s successful Verdi DPSS 532 nm laser as the…

Lasers | Photonics Handbook®

Lasers | Photonics Handbook®


For example, the surface of precision lenses and mirrors is measured using laser interferometers, and so are the minute variations in the interference patterns
of miles-long interferometers used to chase and detect gravitational waves.
Figure 3. Laser light differs from conventional…

Vitara CEP Stabilizer

Vitara CEP Stabilizer

…HERE Overview Vitara-CEP consists of CEP actuators incorporated in the Vitara-T, a quasi-collinear f-to-2f interferometer and a wide bandwidth electronics feedback loop. The interferometer uses a photonic crystal fiber to generate an octave-scanning optical spectrum. The red end of this spectrum…

CEP for Legend Elite Amplifiers

CEP for Legend Elite Amplifiers

…peak of the oscillating electrical field can be maximized under the phase envelope. At the heart of the Legend Elite CEP is a non-linear interferometer. An octave-spanning optical spectrum is generated by focusing a small part of the amplifier beam on a sapphire plate. The red end of this spectrum…

Microelectronics

Microelectronics

…processing. Related Products AVIA NX HyperRapid NX Fiber Bragg Grating Manufacturing A deep-UV excimer or ion laser, in conjunction with an interferometer or a phase mask, can create an intense fringe pattern in an irradiated Germanium-doped fiber, inducing a permanent periodic modulation structure…

2016-Ultrafast-Laser-Systems-Catalog.pdf

2016-Ultrafast-Laser-Systems-Catalog.pdf


Vitara CEP consists of CEP actuators incorporated in
the Vitara-T, a quasi-collinear f-to-2f interferometer
and a wide bandwidth electronics feedback loop.The
interferometer uses a photonic crystal fiber to generate an octave-scanning optical spectrum.The red end
of this…

COHR RLScatalog 2017revA web.pdf

COHR RLScatalog 2017revA web.pdf


Vitara CEP consists of CEP actuators incorporated in
the Vitara-T, a quasi-collinear f-to-2f interferometer
and a wide bandwidth electronics feedback loop.The
interferometer uses a photonic crystal fiber to generate an octave-scanning optical spectrum.The red end
of this…

High Power 7-GHz Bandwidth External-Cavity Diode Laser Array and Its Use in Optically Pumping Singlet Delta Oxygen.pdf

High Power 7-GHz Bandwidth External-Cavity Diode Laser Array and Its Use in Optically Pumping Singlet Delta Oxygen.pdf

…due to the limited resolution bandwidth (0.08-nm) of the OSA.
Therefore, we build a scanning Fabry-Perot interferometer for identifying the ECDLA's
bandwidth. The FP interferometer uses two plane mirrors parallel to each other and spaced 6-
mm apart (free spectral range = 25 GHz). A…

COHR WP  OPSL Invariant Beam Properties final 5.3.18.pdf

COHR WP OPSL Invariant Beam Properties final 5.3.18.pdf

…reflected from a super-flat reference mirror. A second beamsplitter recombines
these reflected beams in a configuration called a Mach-Zehnder interferometer. The recombined
beam is then expanded and viewed using a CCD camera.
If the OPSL chip remains flat with no thermal lensing, then…

COHR WP Ablation of BioPolymers 193nm.pdf

COHR WP Ablation of BioPolymers 193nm.pdf


mJ/cm2 to a maximum of 4.5 J/cm2. Etch depths were established by measuring the depths of the
ablation craters using a White Light Interferometer (WLI). From these measurements, an ablation
threshold of FT = 80±10 mJ/cm2 was extrapolated as shown in figure 3. As expected, ablation…

Photonics Spectra - October 2016

Photonics Spectra - October 2016

…multiwavelength interferometer built into
freely moving measurement heads that
allow a user to measure parts with large
aspheric departure or very steep curvature
with interferometric accuracies.
"Also, the recently released tilted wave
interferometer is reducing full…