Search Results

Refine

Result Type

1 - 12 of 36 Products for 'Interlock Open' Page 1 of 3 |

Interlock Open

Paladin Advanced Preinstallation.book

Paladin Advanced Preinstallation.book

Interlock The system will not operate with the interlock open. An INTERLOCK connector is located on the master power supply rear panel
(see Figure 4-2). The interlock status is monitored by the CPU of the
control board located in the master power supply. If the interlock is
opened, a…

Avia preinstall.book

Avia preinstall.book

…connected by the umbilical.
External Interlock The system will not operate with the interlock open. An interlock
connector is located on the power supply rear panel. The interlock
status is monitored by the CPU. If the interlock is open, a message
will be displayed of the power…

Book.book

Book.book

…event that a door or panel is opened). The interlock
switch must be wired in series with the interlock RCA connector.
INTERLOCK
Open = Laser Off
Closed = Laser On
NOTICE!
The interlock is a fused + 5 VDC line. Do not ground the
interlock or apply any outside power…

Coherent Magnum II Laser Operator's Manual

Coherent Magnum II Laser Operator's Manual

…the interlock plug (supplied
with the unit) into the interlock connector for normal
laser operation. The beam will automatically shut off if
the interlock plug is not in the interlock connector.
· For Interlock System--When the interlock circuit is
opened, the laser…

Picosecond laser

Picosecond laser

…external interlock switch
2 Shutter safety switch
3 Shutter safety switch
4 Minus (-) external interlock switch
5 Shutter push button
6 Shutter push button
External Interlock Pin 1 together with pin 4 can be used to realize an external
interlock. Opening this chain…

Coherent BioRay Operator's Manual

Coherent BioRay Operator's Manual

…the two wires
of the 1/8-inch interlock plug to a door contact switch (remove
the cover and solder from the interlock connector, then solder
the two leads to the correct pins and replace the cover).
Opening the door will open the Interlock circuit and the laser
will turn…

00 E-1000 PreInst.book

00 E-1000 PreInst.book

…Fault 0 No Faults Detected - Reset Faults State
NODE FAULTS (0X01-0X7F)
RFPS SWR 0x01 RF SWR exceeds maximum
Shutter Interlock 0x02 Shutter Interlock Open
Shutter Transition 0x03 Shutter Transition Failure
Node Temperature 0x04 Node Temperature Out of Range
Node Dew…

Verdi preinstall.book

Verdi preinstall.book

…7
External
Interlock
The system will not operate with the interlock open. An interlock
connector is located on the power supply rear panel. The interlock
status is monitored by the CPU. If the interlock is open, the message,
"External Interlock Fault" will be displayed…

Preinstallation Manual Paladin Advanced Mode Locked UV Laser System

Preinstallation Manual Paladin Advanced Mode Locked UV Laser System

Interlock The system will not operate with the interlock open. An INTERLOCK connector is located on the master power supply rear panel
(see Figure 4-2). The interlock status is monitored by the CPU of the
control board located in the master power supply. If the interlock is
opened, a…

Diamond J-5 Series OEM Lasers Preinstallation Manual, Rev. AC


System Interlock
Circuit
Figure 4-12 shows the interlock schematic for the System Interlock
Circuit. INTERLOCK+ goes to pin 24 of Extended I/O.
INTERLOCK_FLAG is an internal signal used to enable and
disable laser operation. Note that the INTERLOCK+ has an

Vitara Preinstall.book

Vitara Preinstall.book


LASER RADIATION WHEN
OPEN AND INTERLOCK
DEFEATED!
AVOID EYE OR SKIN
EXPOSURE TO DIRECT
OR SCATTERED RADIATION.
CLASS IV LASER PRODUCT
808-5275
VISIBLE AND/OR INVISIBLE
LASER RADIATION WHEN
OPEN AND INTERLOCK
DEFEATED!
AVOID EYE OR…

Diamond J-2 Series OEM Lasers Preinstallation Manual, Rev. AB

…Manual
4 - 22
Figure 4-12. System Interlock Circuit
System Interlock circuit. INTERLOCK+ goes to pin 24 of
Extended I/O. INTERLOCK_FLAG is an internal signal
used to enable and disable laser operation. Note that
INTERLOCK+ has an open-circuit voltage of 48 V, and