Table 4-1 provides a description of the LED indicator. Critical
signals, which control laser power, are the pulse width and pulse
period. Typical laser output power for various operating pulse
widths and periods is shown in Section Five: Operation in the operator's manual.

COHR DIAMOND J-3 DS 0617 1.pdf

COHR DIAMOND J-3 DS 0617 1.pdf

…(non-condensing) (%) 95
Altitude 2000 m (6500 ft.)
1 All specifications apply when the product is operated in accordance with the guidelines defined in the operators manual.
2 Measured at 10 kHz PRF, 60% duty cycle.
3 Output stability specification may not be met at lowest…

COHR DIAMOND Cx-10 DS 0118 1.pdf

COHR DIAMOND Cx-10 DS 0118 1.pdf

…of delivery that the Diamond J-3 Series product is free from defects in material
and workmanship. The warranty does not apply to any unit damaged by accident, abuse or operation in a manner inconsistent with the procedures and specifications outlined in the manual supplied with the laser.

COHR DIAMOND J-3-5 COlaser DS 0617 2.pdf

COHR DIAMOND J-3-5 COlaser DS 0617 2.pdf

…(6500 ft.)
Dry Purge Gas Requirements12 (cfm) >2
1 All specifications apply when the product is operated in accordance with the guidelines defined in the operators manual.
2 Measured at 1 kHz PRF, 60% duty cycle.
3 Output stability specification may not be met at lowest power…

Diamond J-3 Series OEM Lasers Preinstallation Manual, Rev. AC

Diamond J-3 Series OEM Lasers Preinstallation Manual, Rev. AC

…Preface This manual provides preinstallation instructions for DIAMONDTM
J-3 Series lasers - OEM version. The laser safety section must be
reviewed thoroughly prior to operating the DIAMOND J-3 Series
laser system.
NOTICE!
Read the DIAMOND J-3 Operator's Manual (1279710)…

FieldMaxII-TOP User Manual

FieldMaxII-TOP User Manual

Operation
4 - 15
When area correction is enabled in Joules or Watts mode, a "/
cm2" will be appended to the units.
The Range Hint annunciator displays the full-scale range value with
the engineering prefix and units omitted. For example, when the
range is 30 J, the…

FieldMaxII-P User Manual

FieldMaxII-P User Manual

Operation
4 - 11
When area correction is enabled in Joules mode, a "/cm2" will
be appended to the units.
The Range Hint annunciator displays the full-scale range value with
the engineering prefix and units omitted. For example, when the
range is 30 J, the Range Hint…