1 - 12 of 175 Products for 'J 100' Page 1 of 15 |

J 100

High Rep-Rate EnergyMax Sensors

High Rep-Rate EnergyMax Sensors

…threshold, high repetition rate operation and reduced specular reflectance
* Operate from 190 nm to 2.1 µm
* Enable pulse energy measurements from 100 nJ to 1J
* Spectral compensation characteristics built into each unit
* Onboard sensors provide automatic temperature compensation Contact Us About…

YAG/Harmonics and IR Sensors

YAG/Harmonics and IR Sensors

…when used with pulsed lasers used in medical procedures such as Erbium and Holmium lasers. It has a damage threshold in excess of 100 J/cm at 2940 nm with a 100 µs pulse width. YAG/Harmonics and IR Series products are also “smart” sensors, and incorporate onboard electronics to automatically…

LEAP

LEAP

…Energy (mJ) Max. Power (W) LEAP 50A 193 200 250 50 LEAP 60A 193 150 400 60 LEAP 80K 248 125 650 80 LEAP 80C 308 125 650 80 LEAP 100K 248 100 1000 100 LEAP 100C 308 100 1000 100 LEAP 130K 248 200 650 130 LEAP 130C 308 200 650 130 LEAP 150K 248 150 1000 150 LEAP 150C 308 150 1000 150 LEAP 300K 248 300…

GeoLasHD excimer ablation laser system

GeoLasHD excimer ablation laser system

…on Sample (µm) 2 - 160 Optical Resolution (µm) 1 Pulse Energy Stability (%, rms) 1 Beam Homogeneity (%, rms) 1 Max. Repetition Rate (Hz) 10 (opt. 100) X,Y-Drive Min. Step Size (µm) 0.1 Z-Focus Min. Step Size (µm) 0.1 GeoLasHD Key Features Ultrashort 193 nm wavelength for ablation in every material…

COHR DIAMOND J-5 DS 1117 1.pdf

COHR DIAMOND J-5 DS 1117 1.pdf

…10 kHz PRF, max. duty cycle.
3 Output stability specification may not be met at lowest power or at acoustic resonances.
4 Measured for a 100 µs pulse width at 1 kHz repetition frequency.
5 Measured as ±(Pmax-Pmin)/2Pmax.
6 Measured at waist location ~1.0 m from the laser output.…

DIAMOND J-5 Series OEM Lasers Preinstallation Manual Rev AA

DIAMOND J-5 Series OEM Lasers Preinstallation Manual Rev AA

DIAMOND J-5 Series OEM Lasers Operator's Manual
3 - 8
Coolant Composition The required coolant composition is a mixture of clean distilled or
deionized water containing a low toxicity corrosion inhibitor. THE
USE OF CORROSION INHIBITOR IS MANDATORY IN THE J-5
LASER. Coherent…

DIAMOND J-5V Series OEM Lasers Preinstallation Manual, Rev. AA

DIAMOND J-5V Series OEM Lasers Preinstallation Manual, Rev. AA

DIAMOND J-5V Series OEM Lasers Preinstallation Manual Preliminary: December 18, 2015
3 - 8
Coolant Composition The required coolant composition is a mixture of clean distilled or
deionized water containing a low toxicity corrosion inhibitor. THE
USE OF CORROSION INHIBITOR IS…

DIAMOND J-3 Series OEM Lasers Preinstallation Manual, Rev. AB

DIAMOND J-3 Series OEM Lasers Preinstallation Manual, Rev. AB

DIAMOND J-3 Series OEM Lasers Operator's Manual
3 - 8
Coolant Composition The required coolant composition is a mixture of clean distilled or
deionized water containing a low toxicity corrosion inhibitor. THE
USE OF CORROSION INHIBITOR IS MANDATORY IN THE J-3
LASER. Coherent…

Diamond J-3-5 Series OEM Lasers Preinstallation Manual, Rev. AA

Diamond J-3-5 Series OEM Lasers Preinstallation Manual, Rev. AA

DIAMOND J-3-5 Series OEM Lasers Preinstallation Manual
3 - 8
Coolant Composition The required coolant composition is a mixture of clean distilled or
deionized water containing a low toxicity corrosion inhibitor.
Coherent has tested three different solutions that will prevent…

Diamond J-5 Series OEM Lasers Preinstallation Manual, Rev. AC

Utility Requirements and System Installation
3 - 7
Coolant Filtering To prevent accumulation of debris in the cooling system, the coolant
should be filtered at the inlet to the laser system.
Coherent recommends the use of hose with an ID of 3/8" (10 mm)
or greater to…

Diamond J-3 Series OEM Lasers Preinstallation Manual, Rev. AC

Diamond J-3 Series OEM Lasers Preinstallation Manual, Rev. AC

…0.1
1.0
10.0
100.0
1,000.0
0 50 100 150 200 250 300
Nominal Ocular Hazard Distance (meters)
Laser Power (W)
Nominal Ocular Hazard Distance
Collimated Beam straight out of the laser
Diuse (Lamberan) Reecon
Focused Beam - 100 um diameter spot

Diamond J-2 Series OEM Lasers Preinstallation Manual, Rev. AB

…0.1
1.0
10.0
100.0
1,000.0
0 50 100 150 200 250 300
Nominal Ocular Hazard Distance (meters)
Laser Power (W)
Nominal Ocular Hazard Distance
Collimated Beam straight out of the laser
Diuse (Lamberan) Reecon
Focused Beam - 100 um diameter spot