Innova Ion Laser Systems 10 TYPES OF WATER SYSTEMS Water systems for laser cooling can be grouped into three major types: · Flow through: The water passes through the laser once and does not return. Tap water is an example. · Closed-loop heat exchanger: The cooling water circulates around a closed…

Verdi Lasers

Verdi Lasers

lasers with continuous wave power up to 20W at 532 nm. Verdi is the preferred pump laser for Ti:Sapphire oscillators and amplifiers. The Verdi G-Series (OPSL technology) is available at 2W, 5W, 7W, 8W, 10W, 12W, 15W, 18W and 20W. For single frequency applications such as holography and atom cooling

00 Laser Cooling.book

00 Laser Cooling.book

…load produced by each Innova laser system is listed in Table 3. If you are using a closed-loop cooling system, be certain that it has sufficient capacity to handle the heat load as listed for your system in Table 3. Table 3. Heat Loads Produced by Innova Lasers LASER SYSTEM HEAT LOAD ALL Sabre 55 kW…

00 Laser Cooling.book

00 Laser Cooling.book

…in the laser system, thereby causing premature failure of the laser system. Construction Materials for Cooling Systems The laser cooling path contains the materials listed in Table 5. Recommended and prohibited materials for the use in the construction of a cooling water delivery system are listed…

00 Laser Cooling.book

00 Laser Cooling.book

…the laser. This offers important advantages: the laser cooling water can be easily monitored and treated to give it optimum quality, while its flow rate, temperature, and pressure can be controlled for optimum laser performance. Water-to-water heat exchangers are often used in laser cooling systems.

00 Laser Cooling.book

00 Laser Cooling.book

Laser Cooling Water Guidelines for Innova® Ion Laser Systems 5100 Patrick Henry Drive Santa Clara, CA 95054

00 Laser Cooling.book

00 Laser Cooling.book

Laser Cooling Water Guidelines for Innova® Ion Laser Systems 5100 Patrick Henry Drive Santa Clara, CA 95054

Mephisto/Mephisto-S

Mephisto/Mephisto-S

…circuitry located in the laser head minimizes the residual pump diode and relaxation oscillation noise at frequencies below 1 MHz. Datasheet Mephisto Mephisto S Drawing Mephisto S Applications Application Gravitational Wave Studies Atom Cooling and Trapping High Power Laser Locking and Seeding…

Preinstallation Manual Paladin Advanced Mode Locked UV Laser System

Preinstallation Manual Paladin Advanced Mode Locked UV Laser System

Installation 3 - 9 Cooling System 1. Connect the two black hoses to the chiller. 2. Connect the open ends of the two black hoses to the laser head. Flow direction is not important. See Figure 3-7. 3. Flush system with distilled water, then fill with NALCOTM (see "Appendix A: MSDS and Directions for…

00 Laser Cooling.book

00 Laser Cooling.book

…on the Laser System .................................................v Introduction ......................................................................................................................1 Function of Cooling Water…

DIAMOND J-3 Series OEM Lasers Preinstallation Manual, Rev. AB

DIAMOND J-3 Series OEM Lasers Preinstallation Manual, Rev. AB

System Description 1 - 11 LIQUID COOLING Composition Distilled or de-ionized water plus corrosion inhibitor Flow Rate > 5.7 lpm (> 1.5 gpm) Heat Load (3) < 4.8 kW (< 16 kBtu/hr) Maximum Static Pressure 827 kPa (120 psi) Pressure Differential (4) 103kPa (15 psi) @ 5.7 lpm (1.5 gpm) Set Temperature…

00 E-250 Pre.book

00 E-250 Pre.book

lasers require water with a corrosion inhibitor additive as the cooling medium to remove heat from the laser head and RF power module. Temperature probes and circuits within the laser head and RF power module continuously monitor the laser temperature whenever the laser is on. If the internal laser

Powered by Site Search powered by SLI Systems

Please Read Before Continuing

Risk factors: Except for the historical information contained here, many of the matters discussed in this Web site are forward-looking statements, based on expectations at the time they were made, that involve risks and uncertainties that could cause our results to differ materially from those expressed or implied by such statements. These risks are detailed in the “Factors That May Affect Future Results” section of our latest 10-K or 10-Q filing. Coherent assumes no obligation to update these forward-looking statements.