1 - 12 of 35 Products for 'Legend Elite Usp' Page 1 of 3 |

Legend Elite Usp

Legend-Elite-Duo-HE-Data-Sheet.pdf

Legend-Elite-Duo-HE-Data-Sheet.pdf

Ultrafast Ti:Sapphire Amplifier Legend Elite Duo HE+ System Specifications1 Legend Elite Duo HE+ Center Wavelength2 (nm) 795 to 805 780 to 820 Pulse Width Configuration Pulse Width (fs)(FHWM) USX USP F P 1000:1 Post-pulse >100:1 Power Stability9,10 (%)(rms) 8.0 at 1 kHz >10.0 at 1 kHz >13.0 at 1 kHz…

2016-Ultrafast-Laser-Systems-Catalog.pdf

2016-Ultrafast-Laser-Systems-Catalog.pdf

…Performance · www.Coherent.com · tech.sales@coherent.com52 Legend Elite HE+ High-Performance, kHz Repetition-Rate,Ti:Sapphire Amplifiers Legend Elite HE+ CenterWavelength2 (nm) 795to805 780to820 PulseWidthConfiguration USX USP F P PulseWidth(fs)(FHWM) 1000:1 Post-pulse >100:1 PowerStability9,10…

00 Legend Elite Preinstallation.book

00 Legend Elite Preinstallation.book

…for most Legend Elite DUO HE+ systems. An additional pump laser is configured for power and energy-hungry applications. Legend Elite Pulse Width & RepRate Options All Legend Elite lasers are available in 4 different pulse width configurations - P (500 to 1500 fs), F (< 130 fs), USP (< 35 fs),…

2016-Ultrafast-Laser-Systems-Catalog.pdf

2016-Ultrafast-Laser-Systems-Catalog.pdf

…Performance · www.Coherent.com · tech.sales@coherent.com52 Legend Elite HE+ High-Performance, kHz Repetition-Rate,Ti:Sapphire Amplifiers Legend Elite HE+ CenterWavelength2 (nm) 795to805 780to820 PulseWidthConfiguration USX USP F P PulseWidth(fs)(FHWM) 1000:1 Post-pulse >100:1 PowerStability9,10…

00 Legend Elite Preinstallation.book

00 Legend Elite Preinstallation.book

Legend Elite HE+ & Duo HE+ Preinstallation Manual 1 - 10 Figure 1-2. Legend Elite HE+ USP Safety Labels (Covers Removed) 3 3 3 3 3 10 10

2016-Ultrafast-Laser-Systems-Catalog.pdf

2016-Ultrafast-Laser-Systems-Catalog.pdf

…and output energy stability · Complete CEP amplifier system from a single manufacturer · Available for Legend Elite USX and USP models Legend Elite CE Phase Stability GUI for Legend Elite CEP Time (minutes) CEPhase(rad) -3 0 3 -2 -1 0 1 2 10 20 30 40 50 60 154 mrad (rms) Laser Measurement and…

00 Legend Elite Preinstallation.book

00 Legend Elite Preinstallation.book

Legend Elite HE+ & Duo HE+ Preinstallation Manual 1 - 10 Figure 1-2. Legend Elite HE+ USP Safety Labels (Covers Removed) 3 3 3 3 3 10 10

00 Legend Elite Preinstallation.book

00 Legend Elite Preinstallation.book

Legend Elite HE+ & Duo HE+ Preinstallation Manual 1 - 10 Figure 1-2. Legend Elite HE+ USP Safety Labels (Covers Removed) 3 3 3 3 3 10 10

00 Legend Elite Preinstallation.book

00 Legend Elite Preinstallation.book

v LIST OF FIGURES 1-1. Legend Elite HE+ Femto/Pico Safety Labels (Covers Removed)................................... 1-9 1-2. Legend Elite HE+ USP Safety Labels (Covers Removed)............................................ 1-10 1-3. Legend Elite HE+ USX Safety Labels (Covers Removed)…

00 Legend Elite Preinstallation.book

00 Legend Elite Preinstallation.book

v LIST OF FIGURES 1-1. Legend Elite HE+ Femto/Pico Safety Labels (Covers Removed)................................... 1-9 1-2. Legend Elite HE+ USP Safety Labels (Covers Removed)............................................ 1-10 1-3. Legend Elite HE+ USX Safety Labels (Covers Removed)…

00 Legend Elite Preinstallation.book

00 Legend Elite Preinstallation.book

v LIST OF FIGURES 1-1. Legend Elite HE+ Femto/Pico Safety Labels (Covers Removed)................................... 1-9 1-2. Legend Elite HE+ USP Safety Labels (Covers Removed)............................................ 1-10 1-3. Legend Elite HE+ USX Safety Labels (Covers Removed)…

00 Legend Elite Preinstallation.book

00 Legend Elite Preinstallation.book

…for most Legend Elite DUO HE+ systems. An additional pump laser is configured for power and energy-hungry applications. Legend Elite Pulse Width & RepRate Options All Legend Elite lasers are available in 4 different pulse width configurations - P (500 to 1500 fs), F (< 130 fs), USP (< 35 fs),…

Powered by Site Search powered by SLI Systems

Call 1-800-227-8840


Outside the U.S. 1-408-764-4983

Coherent has locations across the globe that are available to provide support for any product, service or inquiry.

Visit our Contact Page to connect with any of our global sites.


Corporate Headquarters
Coherent Inc.
5100 Patrick Henry Drive
Santa Clara, CA 95054 USA

email: tech.sales@coherent.com

Send Us a Message

Please Read Before Continuing

Risk factors: Except for the historical information contained here, many of the matters discussed in this Web site are forward-looking statements, based on expectations at the time they were made, that involve risks and uncertainties that could cause our results to differ materially from those expressed or implied by such statements. These risks are detailed in the “Factors That May Affect Future Results” section of our latest 10-K or 10-Q filing. Coherent assumes no obligation to update these forward-looking statements.


I have read the terms and conditions