Search Results

1 - 12 of 13 Products for 'Line Beam 1300' Page 1 of 2 |
Related Categories: Line Beam | Linebeam | Oled | Annealing | Linebeam 1500

Line Beam 1300

LineBeam systems | Coherent

LineBeam systems | Coherent

…Semiconductor --> Features & Benefits LineBeam Model LineBeam 750 LineBeam 1000 LineBeam 1300 LineBeam 1500 Wavelength (nm) 308 308 308 308 Line Beam Length (mm) 750 1000 1300 1500 Beam Profile Type Top-hat along both axes Top-hat along both axes Top-hat along both axes Top-hat along…

FutureElectronics June2014.pdf

FutureElectronics June2014.pdf

…a combined power of 2,400 W. The four
oscillator beams enter the LineBeam
opticaldeliverysystemseparatelyand
will successively be mixed, expanded
and superimposed. Finally, the spatially combined line shaped beam of
1,300 mm length is projected onto
the substrate which…

Photonics Spectra - September 2016

Photonics Spectra - September 2016

…system
with 1300-mm line beam length
Each individual VYPER oscillator can
deliver a total power of 1.2 W (2 joules) at
a 6000-Hz repetition rate. The first fouroscillator system increased this to 2.4 kW
in 2013, providing a line beam length of
1300 mm for large-format…

VYPER-Data-Sheet-Aug-2015.pdf

VYPER-Data-Sheet-Aug-2015.pdf

…costs per Watt UV · Multiple beam system · EquiSwitch synchronization · Laser data acquisition · Sealed and purged beam path · Ethernet interface VYPER Options: · Motorized Alignment · Pulse Shape Analysis · Alternating Triggering · ExiScope Laser Data Analysis · Line Voltage Transformer Very High…

ChameleonVision DS 0216 3.pdf

ChameleonVision DS 0216 3.pdf

…<15 at 90 VAC (power supply)
<7 at 90 VAC (chiller)
<2 at 90 VAC (MRU x1)
System Power Consumption (W) 2300 max., 1300 typical
Line Frequency (Hz) 47 to 63
Operating Temperature Range 15 to 35°C (59 to 95°F)
Non-operating Temperature Range 5 to 40°C (41 to…

ChameleonVision-S DS 0216 3.pdf

ChameleonVision-S DS 0216 3.pdf

…<15 at 90 VAC (power supply)
<7 at 90 VAC (chiller)
<2 at 90 VAC (MRU x1)
System Power Consumption (W) 2300 max., 1300 typical
Line Frequency (Hz) 47 to 63
Operating Temperature Range 15 to 28°C (59 to 82.5°F)
Non-operating Temperature Range 5 to 40°C (41 to…

COHR ChameleonVision-S DS 0517 3.pdf

COHR ChameleonVision-S DS 0517 3.pdf

…(A) <15 at 90 VAC (power supply)
<7 at 90 VAC (chiller)
<2 at 90 VAC (MRU)
System Power Consumption (W) 2300 max., 1300 typical
Line Frequency (Hz) 47 to 63
MECHANICAL PARAMETERS
Weight of Laser Head 52 kg (115 lbs.)
Weight of Power Supply 33 kg (73 lbs.)…

ChameleonVision DS

ChameleonVision DS

…<15 at 90 VAC (power supply)
<7 at 90 VAC (chiller)
<2 at 90 VAC (MRU x1)
System Power Consumption (W) 2300 max., 1300 typical
Line Frequency (Hz) 47 to 63
Operating Temperature Range 15 to 35°C (59 to 95°F)
Weight of Laser Head 52 kg (115 lbs.)
Weight of…

ChameleonLightning DS

ChameleonLightning DS

…<15 at 90 VAC (power supply)
<7 at 90 VAC (chiller)
<2 at 90 VAC (MRU x1)
System Power Consumption (W) 2300 max., 1300 typical
Line Frequency (Hz) 47 to 63
Operating Temperature Range 15 to 28°C (59 to 82.5°F)
Storage Temperature Range 5 to 40°C (41 to 104°F)…

Laser Focus World - May 2015

Laser Focus World - May 2015

…Clara, CA) produces a full line of ultrafast lasers, including oscillators, amplifiers, and single-wavelength lasers. The company's InSight DS+
system, which is intended for scientific applications such as in vivo multiphoton microscopy, has a very large 680 to 1300 nm
gap-free tuning…

2015.7.4 10Q

2015.7.4 10Q

…the 750 product, we had developed L-3 Communications' Tinsley division ("Tinsley") as our sole source
supplier for the 1300nm and 1500nm optics needed for our Linebeam 1300 and 1500 products. L-3 made a strategic decision to
exit this business and we decided to acquire the business rather…

ChameleonUltra DS 16-02-16  F.pdf

ChameleonUltra DS 16-02-16 F.pdf

…<15A at 90 VAC (power supply)
<7A at 90 VAC (chiller)
<2A at 90 VAC (MRU X1)
System Power Consumption 2300W max., 1300W typical
Line Frequency 47 to 63 Hz
Operating Temperature Range 15 to 35°C (59 to 95°F)
Non-operating Temperature Range 5 to 40°C (41 to…

Powered by Site Search powered by SLI Systems

Please Read Before Continuing

Risk factors: Except for the historical information contained here, many of the matters discussed in this Web site are forward-looking statements, based on expectations at the time they were made, that involve risks and uncertainties that could cause our results to differ materially from those expressed or implied by such statements. These risks are detailed in the “Factors That May Affect Future Results” section of our latest 10-K or 10-Q filing. Coherent assumes no obligation to update these forward-looking statements.


I have read the terms and conditions