Ask a Question
Coherent
Search Results
Refine
1 - 12 of 32 Products for 'Lm 5000' Page 1 of 3 |

Lm 5000

Position Sensing Water Cooled Thermopile Sensors 5kW

Position Sensing Water Cooled Thermopile Sensors 5kW

Position Sensing Water-Cooled Thermopile Sensors to 5 kW (RoHS) Sensors useful for non-visible beams.
* 100W to 5000W range
* Broadband coatings
* 0.25 to 10.6 µm spectral range
* Compact water-cooled design
* Large 38 mm or 55 mm diameter aperture
* Escellent for high-power CO2 and Nd:YAG lasers
*…

PowerMax-USB sensors

PowerMax-USB sensors

PowerMax-USB Sensors Laser Measurement device providing direct USB 2.0 connection to a PC.

Key Features:
* PowerMax USB provides direct USB 2.0 connection to PC. Power provided via USB connection.
* Instrumentation platform is compatible with thermopiles and optical sensors and can be adapted to…

COHERENT LMC 2016-2017 Catalog .pdf

COHERENT LMC 2016-2017 Catalog .pdf

…2500 100 to 5000 Resolution (W) 1 Max. Power Density1 1 to 2.5 kW/cm2 Max. Energy Density 0.5 J/cm2, 1064 nm, 10 ns Detector Coating H Active Area Diameter (mm) 35 38 56 Calibration Uncertainty (%)(k=2) ±5 Calibration Wavelength (µm) 10.6 Cooling Method Water-cooled Cable Type LM DB-25 Cable Length…

Thermal Smart Sensor Adapter

Thermal Smart Sensor Adapter

Thermal SmartSensor Adapter Provides compatibility between thermal and optical sensors, and meters. The Thermal SmartSensor Adapter provides compatibility between Coherent thermal and optical sensors (LM-model sensors), and the meters listed in the meter compatibility matrix. Contact Us About This…

Laser-Measurement-and-Control-Catalog FORMFIRST.pdf

Laser-Measurement-and-Control-Catalog FORMFIRST.pdf

…10600 5 LM DB-25 Position-Sensing Water-Cooled Thermopile Sensors (to 5 kW) 1098409 LM-1000 0.25 to 10.6 100W 1000W 1W - 38 Broadband 10600 5 LM DB-25 1098437 LM-2500 0.25 to 10.6 100W 2500W 1W - 55 Broadband 10600 5 LM DB-25 1098421 LM-5000 0.25 to 10.6 100W 5000W 1W - 55 Broadband 10600 5 LM DB-25…

Laser-Measurement-and-Control-Catalog FORMFIRST.pdf

Laser-Measurement-and-Control-Catalog FORMFIRST.pdf

…10600 5 LM DB-25 Position-Sensing Water-Cooled Thermopile Sensors (to 5 kW) 1098409 LM-1000 0.25 to 10.6 100W 1000W 1W - 38 Broadband 10600 5 LM DB-25 1098437 LM-2500 0.25 to 10.6 100W 2500W 1W - 55 Broadband 10600 5 LM DB-25 1098421 LM-5000 0.25 to 10.6 100W 5000W 1W - 55 Broadband 10600 5 LM DB-25…

Laser-Measurement-and-Control-Catalog FORMFIRST.pdf

Laser-Measurement-and-Control-Catalog FORMFIRST.pdf

…10600 5 LM DB-25 Position-Sensing Water-Cooled Thermopile Sensors (to 5 kW) 1098409 LM-1000 0.25 to 10.6 100W 1000W 1W - 38 Broadband 10600 5 LM DB-25 1098437 LM-2500 0.25 to 10.6 100W 2500W 1W - 55 Broadband 10600 5 LM DB-25 1098421 LM-5000 0.25 to 10.6 100W 5000W 1W - 55 Broadband 10600 5 LM DB-25…

COHERENT LMC 2016-2017 Catalog .pdf

COHERENT LMC 2016-2017 Catalog .pdf

…10600 5 LM DB-25 Position-Sensing Water-Cooled Thermopile Sensors (to 5 kW) 1098409 LM-1000 0.25 to 10.6 100W 1000W 1W - 38 Broadband 10600 5 LM DB-25 1098437 LM-2500 0.25 to 10.6 100W 2500W 1W - 55 Broadband 10600 5 LM DB-25 1098421 LM-5000 0.25 to 10.6 100W 5000W 1W - 55 Broadband 10600 5 LM DB-25…

COHERENT LMC 2016-2017 Catalog .pdf

COHERENT LMC 2016-2017 Catalog .pdf

…10600 5 LM DB-25 Position-Sensing Water-Cooled Thermopile Sensors (to 5 kW) 1098409 LM-1000 0.25 to 10.6 100W 1000W 1W - 38 Broadband 10600 5 LM DB-25 1098437 LM-2500 0.25 to 10.6 100W 2500W 1W - 55 Broadband 10600 5 LM DB-25 1098421 LM-5000 0.25 to 10.6 100W 5000W 1W - 55 Broadband 10600 5 LM DB-25…

Laser-Measurement-and-Control-Catalog FORMFIRST.pdf

Laser-Measurement-and-Control-Catalog FORMFIRST.pdf

…2500 100 to 5000 Resolution (W) 1 Max. Power Density1 1 to 2.5 kW/cm2 Max. Energy Density 0.5 J/cm2, 1064 nm, 10 ns Detector Coating H Active Area Diameter (mm) 35 38 56 Calibration Uncertainty (%)(k=2) ±5 Calibration Wavelength (µm) 10.6 Cooling Method Water-cooled Cable Type LM DB-25 Cable Length…

Laser-Measurement-and-Control-Catalog FORMFIRST.pdf

Laser-Measurement-and-Control-Catalog FORMFIRST.pdf

…2500 100 to 5000 Resolution (W) 1 Max. Power Density1 1 to 2.5 kW/cm2 Max. Energy Density 0.5 J/cm2, 1064 nm, 10 ns Detector Coating H Active Area Diameter (mm) 35 38 56 Calibration Uncertainty (%)(k=2) ±5 Calibration Wavelength (µm) 10.6 Cooling Method Water-cooled Cable Type LM DB-25 Cable Length…

Laser-Measurement-and-Control-Catalog FORMFIRST.pdf

Laser-Measurement-and-Control-Catalog FORMFIRST.pdf

…2500 100 to 5000 Resolution (W) 1 Max. Power Density1 1 to 2.5 kW/cm2 Max. Energy Density 0.5 J/cm2, 1064 nm, 10 ns Detector Coating H Active Area Diameter (mm) 35 38 56 Calibration Uncertainty (%)(k=2) ±5 Calibration Wavelength (µm) 10.6 Cooling Method Water-cooled Cable Type LM DB-25 Cable Length…

Powered by Site Search powered by SLI Systems

Call 1-800-227-8840


Outside the U.S. 1-408-764-4983

Coherent has locations across the globe that are available to provide support for any product, service or inquiry.

Visit our Contact Page to connect with any of our global sites.


Corporate Headquarters
Coherent Inc.
5100 Patrick Henry Drive
Santa Clara, CA 95054 USA

email: tech.sales@coherent.com

Send Us a Message

Please Read Before Continuing

Risk factors: Except for the historical information contained here, many of the matters discussed in this Web site are forward-looking statements, based on expectations at the time they were made, that involve risks and uncertainties that could cause our results to differ materially from those expressed or implied by such statements. These risks are detailed in the “Factors That May Affect Future Results” section of our latest 10-K or 10-Q filing. Coherent assumes no obligation to update these forward-looking statements.


I have read the terms and conditions