Ask a Question
Coherent
Search Results
1 - 12 of 108 Products for 'Locking Cavity' Page 1 of 9 |

Locking Cavity

Mephisto/Mephisto S

Mephisto/Mephisto S

…as an option for all variants. All Mephisto family products utilize a Non-Planar Ring Oscillator (NPRO). This is a miniature monolithic laser cavity with the intracavity path completely inside the Nd:YAG crystal. The combination of this non-planar structure, an externally applied magnetic field,…

Synchrolock-AP

Synchrolock-AP

…delay between locked pulse trains of up to 13 ns with around 22 fs resolution (for a 76 MHz cavity)
* Simple fiberoptic coupling of slave output beam to the Synchrolock-AP detection system results in minimal losses and ease of use
* Unique feedback locking mechanism locks to the 9th harmonic…

Mira 900

Mira 900

…make pump alignment easy
* Auxiliary CW cavity for general setup and continuous- wave operation Options and Accessories
* Short pulse option: 5 ps
* 2nd, 3rd and 4th harmonic generation
* Mira-OPO synchronously-pumped OPO
* Pulse picker
* Pulse switch cavity dumper
* Synchrolock-AP
* SPO-1, SPO-2…

Verdi V-Series

Verdi V-Series

…a patented single longitudinal mode ring cavity architecture enabling single frequency applications. The “green noise” problem, common in other pump lasers, is eliminated with this design. Additionally, the Verdi V is available with a PZT option to lock the frequency and provide narrower linewidth.…

Microsoft Word - Wavelength Control and Locking with Sub-MHz Precision

Microsoft Word - Wavelength Control and Locking with Sub-MHz Precision

…was removed. The concept is simple; lock the Verdi to the "reference" cavity and use the "analyzer" cavity to monitor any residual changes in the Verdi wavelength. Figure 1. The wavelength of a Verdi with a PZT-actuated mirror was locked to the reference cavity. Stabilization of the Verdi wavelength…

Microsoft Word - Wavelength Control and Locking with Sub-MHz Precision

Microsoft Word - Wavelength Control and Locking with Sub-MHz Precision

…the analyzer cavity. An identical locking scheme was used, but the inverted error signal from the analyzer cavity was fed back to a PZT-actuated mirror in the analyzer cavity itself. The length of the analyzer cavity therefore followed wavelength changes of the Verdi to maintain lock. The error…

Microsoft Word - Wavelength Control and Locking with Sub-MHz Precision

Microsoft Word - Wavelength Control and Locking with Sub-MHz Precision

…spectral linewidth of a single-longitudinal-mode laser is the spectral bandwidth of the lasing cavity mode. Like a passive Fabry-Perot cavity, the linewidth of a DPSS laser decreases with cavity finesse and increases with any intra-cavity losses, while the gain narrows the linewidth. In steady-state…

Microsoft Word - Wavelength Control and Locking with Sub-MHz Precision

Microsoft Word - Wavelength Control and Locking with Sub-MHz Precision

Wavelengths Control and Locking with Sub-MHz Precision Page 3 which modulate the resonator length and therefore the wavelength. Acoustic noise, from sources like laboratory equipment or even people, is the dominant contributor to the timeaveraged linewidth. The linewidth of a Verdi is specified as…

MBD200 DSrevB

MBD200 DSrevB

…doubling · MBD E-200 servo-control unit · Efficient doubling of single-frequency Ti:S and dye lasers Superior Reliability & Performance Optical Schematic of the MBD-200 Resonant Frequency Doubler Fundamental Input Lock Photodiodes Resonant Cavity Power Monitor Second Harmonic Output Telescope

MBD200 DSrevB

MBD200 DSrevB

…doubling · MBD E-200 servo-control unit · Efficient doubling of single-frequency Ti:S and dye lasers Superior Reliability & Performance Optical Schematic of the MBD-200 Resonant Frequency Doubler Fundamental Input Lock Photodiodes Resonant Cavity Power Monitor Second Harmonic Output Telescope

MBD200 DSrevB

MBD200 DSrevB

…doubling · MBD E-200 servo-control unit · Efficient doubling of single-frequency Ti:S and dye lasers Superior Reliability & Performance Optical Schematic of the MBD-200 Resonant Frequency Doubler Fundamental Input Lock Photodiodes Resonant Cavity Power Monitor Second Harmonic Output Telescope

Mira brochure

Mira brochure

…option offers automatic cavity-length control. Length actuators are used to lock the cavity repetition rate to an internal crystal oscillator or to an external reference frequency. Computer control allows `one touch' lock acquisition. Mira OPO. The Mira OPO, a synchronously-pumped optical parametric…

Powered by Site Search powered by SLI Systems

Call 1-800-227-8840


Outside the U.S. 1-408-764-4983

Coherent has locations across the globe that are available to provide support for any product, service or inquiry.

Visit our Contact Page to connect with any of our global sites.


Corporate Headquarters
Coherent Inc.
5100 Patrick Henry Drive
Santa Clara, CA 95054 USA

email: tech.sales@coherent.com

Send Us a Message

Please Read Before Continuing

Risk factors: Except for the historical information contained here, many of the matters discussed in this Web site are forward-looking statements, based on expectations at the time they were made, that involve risks and uncertainties that could cause our results to differ materially from those expressed or implied by such statements. These risks are detailed in the “Factors That May Affect Future Results” section of our latest 10-K or 10-Q filing. Coherent assumes no obligation to update these forward-looking statements.


I have read the terms and conditions