Search Results

Refine

Result Type

1 - 10 of 10 Products for 'Loop Fault' Page 1 of 1 |
  • 1

Loop Fault

00 Legend Elite Preinstallation.book

00 Legend Elite Preinstallation.book

…ECU monitors and controls the
temperature of the TEC, and conditions the air flow through the
crystal assembly in a closed loop. The design includes a fault notification for high humidity inside the housing.
Legend Elite DUO HE+ models include a second ECU which
applies the same…

Book.book

Book.book

…Manual
6 - 16
Faults Faults display on the Status bar. Specific information displays when
a temperature fault--including Base Plate and Diode Temperature--is present. Other faults display with a Fault indicator. To
obtain details for other faults, use the Terminal screen and…

Diamond J-5 Series OEM Lasers Preinstallation Manual, Rev. AC

…RF power module and supplies status information from the laser system.
Interface Embedded Control LAN connector for diagnostics and troubleshooting.
Extended I/O Connector DB25 connector that provides extended capability (including shutter control and
additional fault signals).

Diamond J-2 Series OEM Lasers Preinstallation Manual, Rev. AB

…interlock loop which can be
opened with electromechanical switches. It should not be driven
directly by a logic IC, unless it is a high-voltage peripheral driver
capable of withstanding 24 V and capable of sinking at least 9 mA.
Over Temperature
Fault
This output…

00 E-250 Pre.book

00 E-250 Pre.book

…RF power module and supplies status information from the laser system.
Interface Embedded Control LAN connector for diagnostics and troubleshooting.
Extended I/O Connector DB25 connector that provides extended capability (including shutter control and
additional fault signals).

Diamond J-3 Series OEM Lasers Preinstallation Manual, Rev. AC

Diamond J-3 Series OEM Lasers Preinstallation Manual, Rev. AC

…RF power module and supplies status information from the laser system.
Interface Embedded Control LAN connector for diagnostics and troubleshooting.
Extended I/O Connector DB25 connector that provides extended capability (including shutter control and
additional fault signals).

2011-Diode-Laser-Modules-and-Pattern-Generators-Catalog.pdf

2011-Diode-Laser-Modules-and-Pattern-Generators-Catalog.pdf

…Screen
The Status Screen shows the details of the laser from
serial number to operating hours. A separate Fault
Screen also shows any faults from an interlock fault to
over-temperature.
The Control Box
To comply with the CDRH safety requirements for a
Class IIIb…

Vitara Preinstall.book

Vitara Preinstall.book

…panel. If the interlock is open, laser emission will terminate, and
the SYSTEM FAULT LED (red) will illuminate. The system ships
with an interlock defeat which is installed to close the interlock loop.
Alternatively, if you want to incorporate an external safety interlock
circuit…

Diamond J-3-5 Series OEM Lasers Preinstallation Manual, Rev. AA

Diamond J-3-5 Series OEM Lasers Preinstallation Manual, Rev. AA

…Embedded Control LAN connector for diagnostics and troubleshooting.
Extended I/O Connector DB25 connector that provides extended capability (including shutter control and
additional fault signals).
Table 3-5. J-3-5 Head Indicators and Connectors (Continued)
CONTROL FUNCTION

DIAMOND J-5V Series OEM Lasers Preinstallation Manual, Rev. AA

DIAMOND J-5V Series OEM Lasers Preinstallation Manual, Rev. AA

…Interface Embedded Control LAN connector for diagnostics and troubleshooting.
Extended I/O Connector DB25 connector that provides extended capability (including shutter control and
additional fault signals).
Table 3-4. J-5V Head Indicators and Connectors
CONTROL FUNCTION

Please Read Before Continuing

Risk factors: Except for the historical information contained here, many of the matters discussed in this Web site are forward-looking statements, based on expectations at the time they were made, that involve risks and uncertainties that could cause our results to differ materially from those expressed or implied by such statements. These risks are detailed in the “Factors That May Affect Future Results” section of our latest 10-K or 10-Q filing. Coherent assumes no obligation to update these forward-looking statements.


I have read the terms and conditions