Search Results

1 - 12 of 26 Products for 'Low Water Flow' Page 1 of 3 |

Low Water Flow

00 Laser Cooling.book

00 Laser Cooling.book

Water Cooling Guidelines
5
3. Do not allow the flow rate to fall below the minimum specified
value. All Coherent ion lasers have flow sensors inside the
power supply. When a sensor detects a condition of low water
flow, it shuts off the laser to protect the system from…

COHR Genesis MX SLM-Series DS 0517 3.pdf

COHR Genesis MX SLM-Series DS 0517 3.pdf

Single Frequency Visible OEM and End-User OPS Laser Systems Applications like Flow Cytometry, Particle Counting, DNA Sequencing and Microscopy are enable by low noise, visible true CW lasers. The Genesis MX SLM-Series provides up to 1W of visible laser light from either OEM or CDRH-compliant…

Microsoft Word - kW Thermopile Damage Threshold.doc

Microsoft Word - kW Thermopile Damage Threshold.doc

…In many cases this will result in changes of the sensor's sensitivity. This can occur because the power density is too high, the water flow rate is too low, the total input power is above the maximum power rating, or a combination of these. Definition of Damage Threshold The damage threshold…

Diamond J-3 Series OEM Lasers Preinstallation Manual, Rev. AC

Diamond J-3 Series OEM Lasers Preinstallation Manual, Rev. AC

…989-636-1000
Inhibited
Propylene
Glycol and
Water
30% in water At 30% mix will
provide burst
protection to
--25°C (13°F)
See Note below
Table 3-3. Specification Difference
PRODUCT FLOW RATE INPUT PRESSURE
Optishield 5.7 lpm (1.5 gpm) 206…

Diamond J-3-5 Series OEM Lasers Preinstallation Manual, Rev. AA

Diamond J-3-5 Series OEM Lasers Preinstallation Manual, Rev. AA

water containing a low toxicity corrosion inhibitor.
Coherent has tested three different solutions that will prevent corrosion within the laser coolant circuit.
These are described in Table 3-2:
Using Dowfrost at 30% in water changes the heat transfer capacity
of the water and…

DIAMOND J-3 Series OEM Lasers Preinstallation Manual, Rev. AB

DIAMOND J-3 Series OEM Lasers Preinstallation Manual, Rev. AB

…989-636-1000
Inhibited
Propylene
Glycol and
Water
30% in water At 30% mix will
provide burst
protection to
--25°C (13°F)
See Note below
Table 3-3. Specification Difference
PRODUCT FLOW RATE INPUT PRESSURE
Optishield 5.7 lpm (1.5 gpm) 206…

Innova Sabre brochure

Innova Sabre brochure


in single-line, multiline, or
single-frequency operation.
Low-Noise Magnet
Sabre's tangential-flow cooling system
minimizes vibration due to water turbulence. This significantly improves beam
noise and reduces frequency jitter in
single-frequency applications.

Microsoft Word - QI-19.140 revAC.docx

Microsoft Word - QI-19.140 revAC.docx

…and F ations Note he water co he coating o contact with w dryer or h d water is r mperature o ble. The wat water, as col is okay u nt time for t ould run thr ginning the ut water tem than the tim the order o erroneous nded that t her equipm water flow e sensor an ling supply low Specif ates are min…

Diamond J-2 Series OEM Lasers Preinstallation Manual, Rev. AB

…deionized water containing a low toxicity corrosion
inhibitor. Coherent has tested three different solutions that will
prevent corrosion within the laser coolant circuit.
These are described in Table 3-2:
Note on the use of Dowfrost
Using Dowfrost at 30% in water changes the…

Laser Focus World - January 2018

Laser Focus World - January 2018

…LDs, has a flow
path that makes a
180° turn under the
LD. A high-power micro-impingement cooler combines impingement
heat transfer with
manifold microchannel designs--
MC2 says that offthe-shelf coolers
can reach thermal
resistances as low
as 25 K-cm2/kW,…

COHR Genesis MX STM-Series DS 0517 3.pdf

COHR Genesis MX STM-Series DS 0517 3.pdf

TEM00 Visible OEM and End-User OPS Laser Systems Applications like Flow Cytometry, Particle Counting, DNA Sequencing and Microscopy are enable by low noise, visible true CW lasers. The Genesis MX STM-Series provides up to 1W of visible laser light from either OEM or CDRH-compliant end-user systems.…

COHR Genesis CX STM-Series DS 0317 1.pdf

COHR Genesis CX STM-Series DS 0317 1.pdf

…from either OEM or CDRH-compliant end-user systems. Ideal for applications such as Flow Cytometery, Particle Counting, DNA Sequencing and Microscopy, these lasers provide a TEM00 power invariant beam with low noise and high stability in a convenient package. The Genesis CX STM-Series is the perfect…