Search Results

Refine
1 - 9 of 9 Products for 'Master Slave' Page 1 of 1 |
  • 1
Related Categories: Harmonic

Master Slave

Synchrolock-AP

Synchrolock-AP

…while ensuring long-term stability.
* The Synchrolock-AP accessory locks the pulse repetition-rate of one “Slave” Mira or VItara laser to another “Master” Mira or Vitara laser, or to a “Master” external RF source
* Femtosecond (Mira and Vitara) and/or picosecond (Mira only) operation
* Three cavity…

Preinstallation Manual Paladin Advanced Mode Locked UV Laser System

Preinstallation Manual Paladin Advanced Mode Locked UV Laser System

Description and Specifications
1 - 11
MASTER
SLAVE
Figure 1-3. Label Locations - Power Supply
2
1
4
3
5 6
AMPLIFIER
FIBER 3
AMPLIFIER
FIBER 4
2
1
4
3
5 6

Paladin Advanced Preinstallation.book

Paladin Advanced Preinstallation.book

Paladin Mode Locked UV Laser Preinstallation Manual
1 - 10
MASTER
SLAVE
Figure 1-3. Label Locations - Power Supply
2
1
4
3
5 6
2
1
4
3
5 6

2016-Ultrafast-Laser-Systems-Catalog.pdf

2016-Ultrafast-Laser-Systems-Catalog.pdf

…performance and tighter synchronization between slave and master oscillators
· User-friendly GUI enables automatic locking acquisition, delay control and system monitoring
Slave Oscillator Jitter
Mira (fs) Mira (ps) Vitara-T
Master Oscillator
Mira (fs) 250 250 250

COHR RLScatalog 2017revA web.pdf

COHR RLScatalog 2017revA web.pdf

…performance and tighter synchronization between slave and master oscillators
· User-friendly GUI enables automatic locking acquisition, delay control and system monitoring
Slave Oscillator Jitter
Mira (fs) Mira (ps) Vitara-T
Master Oscillator
Mira (fs) 250 250 250

EnergyMax-USB/RS User Manual

EnergyMax-USB/RS User Manual

…position, that is, master or slave.
Command: None
Query: TRIGger:BUS:POSition?
Reply: MAST|SLAV
Bus position is determined by the physical position of devices
stacked in a trigger bus configuration, which is one master and one
or more slaves. Unbussed devices will…

PaladinAdvanced355 Datasheet 2017.pdf

PaladinAdvanced355 Datasheet 2017.pdf

…Voltage
Power Supply 90 to 230 VAC, 50 to 60 Hz
Power Consumption Maximum Operation (typical) Standby (typical)
Power Supply (master & slave) 1000 VA 500 VA 200 VA
Chiller (8W/10W) 1000 VA 500 VA (22°C ambient) 500 VA (22°C ambient)
Chiller (16W/24W) 1600 VA 750 VA (22°C…

Photonics Spectra - September 2016

Photonics Spectra - September 2016

…oscillators.
The two oscillators of the VYPER are arranged in pairs with a master and slave configuration. Patented synchronization circuitry accurately controls the time delay
between the pulses of the slave and master. An active feedback loop is employed
to maintain a stable delay…

ILS Annealing.PDF


in terms of temporal pulse shaping. This is possible because
the two oscillators contained in each VYPER are arranged in a
master and slave configuration. Synchronization and feedback
circuitry accurately controls the time delay between the pulses
of these two oscillators,…