Search Results

Refine

Result Type

1 - 10 of 10 Products for 'Maximum Permissible Exposure' Page 1 of 1 |
  • 1

Maximum Permissible Exposure

00 E-250 Pre.book

00 E-250 Pre.book

…for direct viewing of the collimated beam
along with two other common configurations. The NOHD in this
figure is based on the Maximum Permissible Exposure (MPE = 0.1
W/cm2) level for each power condition as specified in ANSI
Z136.1-2007 and IEC 60825-1-2007 (Rule 2 applies over…

DIAMOND J-3 Series OEM Lasers Preinstallation Manual, Rev. AB

DIAMOND J-3 Series OEM Lasers Preinstallation Manual, Rev. AB

…for direct viewing of the collimated beam along with two
other common configurations. The NOHD in this figure is based on
the Maximum Permissible Exposure (MPE = 0.1 W/cm2) level for
each power condition as specified in ANSI Z136.1-2007 and
IEC 60825-1-2007 (Rule 2 applies over…

DIAMOND J-5 Series OEM Lasers Preinstallation Manual Rev AA

DIAMOND J-5 Series OEM Lasers Preinstallation Manual Rev AA

…for direct viewing of the collimated beam
along with two other common configurations. The NOHD in this
figure is based on the Maximum Permissible Exposure (MPE = 0.1
W/cm2) level for each power condition as specified in ANSI
Z136.1-2007 and IEC 60825-1-2007 (Rule 2 applies over…

Diamond J-3 Series OEM Lasers Preinstallation Manual, Rev. AC

Diamond J-3 Series OEM Lasers Preinstallation Manual, Rev. AC

…for direct viewing of the collimated beam
along with two other common configurations. The NOHD in this
figure is based on the Maximum Permissible Exposure
(MPE = 0.1 W/cm2) level for each power condition as specified in
ANSI Z136.1 and IEC 60825-1 (Rule 2 applies over nearly all…

DIAMOND J-5V Series OEM Lasers Preinstallation Manual, Rev. AA

DIAMOND J-5V Series OEM Lasers Preinstallation Manual, Rev. AA

…direct viewing of the
collimated beam along with two other common configurations. The
NOHD in this figure is based on the Maximum Permissible
Exposure (MPE = 0.1 W/cm2) level for each power condition as
specified in ANSI Z136.1-2007 and IEC 60825-1-2007 (Rule 2
applies over…

Diamond J-3-5 Series OEM Lasers Preinstallation Manual, Rev. AA

Diamond J-3-5 Series OEM Lasers Preinstallation Manual, Rev. AA

…for direct viewing of the collimated beam
along with two other common configurations. The NOHD in this
figure is based on the Maximum Permissible Exposure (MPE = 0.1
W/cm2) level for each power condition as specified in ANSI Z136.1
and IEC 60825-1.
Figure 1-1. Nominal Ocular…

Coherent BioRay Operator's Manual

Coherent BioRay Operator's Manual

…viewing distance of 13 cm between
screen and cornea and a maximum viewing time of 10 sec. Other
viewing conditions require a comparison of the diffuse reflection
exposure with the MPE (maximum permissible exposure limit).
4. Eye protection is required if there is any possibility…

Diamond J-2 Series OEM Lasers Preinstallation Manual, Rev. AB

…for direct viewing of the collimated beam
along with two other common configurations. The NOHD in this
figure is based on the Maximum Permissible Exposure
(MPE = 0.1 W/cm2) level for each power condition as specified in
ANSI Z136.1 and IEC 60825-1 (Rule 2 applies over nearly all…

Diamond J-5 Series OEM Lasers Preinstallation Manual, Rev. AC

…for direct viewing of the collimated beam along with two
other common configurations. The NOHD in this figure is based on
the Maximum Permissible Exposure (MPE = 0.1 W/cm2) level for
each power condition as specified in ANSI Z136.1 and
IEC 60825-1.
Electrical Safety All J-5…

book.book

book.book

…Nominal
Ocular Hazard Distance (NOHD) between the laser or scatter radiation and the
operator's eyes. The NOHD is based on the Maximum Permissible Exposure
(MPE = 0.1 W/cm2) level for each power condition as specified in ANSI Z136.1 and
IEC 60825-1.
The Final Quality Control…

Please Read Before Continuing

Risk factors: Except for the historical information contained here, many of the matters discussed in this Web site are forward-looking statements, based on expectations at the time they were made, that involve risks and uncertainties that could cause our results to differ materially from those expressed or implied by such statements. These risks are detailed in the “Factors That May Affect Future Results” section of our latest 10-K or 10-Q filing. Coherent assumes no obligation to update these forward-looking statements.


I have read the terms and conditions